Laserfiche WebLink
SECOND FLOOR ELECTRICAL PLAN (A, B, K, L & M <br />1 /4" = 1'-0" <br />It <br />ELECTRICAL ROTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK, <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />co <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET co <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />S r2 <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />HORIZONTAL <br />AT 12" - TOP PLUG IS HOT <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET- VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />1 TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />-69 SWITCH AT 36" <br />-69 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />--p PUSH BUTTON FOR GARAGE DOOR OPENER <br />--0 DIMMER SWITCH AT 36" <br />-{I PUSH-BUTTON DOORBELL <br />{- CLG MNT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />-} SURFACE MNT FIXTURE <br />}- WALL MNT FIXTURE <br />NOTE: <br />C TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />C 50W PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />80 50W PAR20 NFL 4" MINI ROUND RECESS <br />,�o) 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />Cos SMOKE DETECTOR <br />C SMOKE DETECTOR <br />=U-18m UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 — UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />— D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24:R 24" VANITY LIGHTING <br />F;F"- 36 :FuR 36" VANITY LIGHTING <br />48-;;;;; 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />GO CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />7M&ZI ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />E3 A/C REGISTER <br />OT THERMOSTAT <br />On SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />f q , <br />N <br />€ <br />D <br />M <br />a <br />° <br />co <br />a <br />4 <br />a <br />A 001 <br />u') <br />O <br />� <br />w <br />O <br />w <br />0 <br />z <br />(no� <br />� 0 LO <br />W L u <br />� 0 c) � ai <br />N� } <br />u O m u <br />AV' <br />` O <br />f� �� Q O C Q <br />.�s <br />wCj' <br />Q N G <br />Oc) M <br />L. p � 01) <br />7W <br />V <br />CL <br />wW <br />U� W <br />ow WoF- <br />LU <br />LLIF ~ o J of< z� <br />�OD�JQO>a�¢LUO�JO <br />I— <br />J 3 Q <br />LWOOW00m <br />J — <br />OZ- <br />rj)UZnZ:��U <br />W QOW0Oz<¢OQWZ <br />�J <br />aQ <br />LL <br />OW �F-F �Wz<< <br />D <br />O= 0 ❑< Of <br />L.Q o F— U- <br />O <br />O <br />Z 04 <br />O� <br />ti <br />z <br />F- M O <br />Q u') <br />J <br />0- (/) <br />2G/)LL_ti <br />z <br />< W <br />co <br />Q 00 <br />Q <br />z U I— <br />z <br />w <br />W <br />J oO <br />a <br />0 <br />02 <br />Virt <br />al R <br />I <br />vievf <br />I' <br />As <br />isf Inc. <br />Plans Rev <br />i w c <br />mp <br />eted <br />and <br />appr <br />v <br />for compliam <br />2 wi <br />h the <br />210 <br />0 FB <br />7t <br />Edi <br />ion <br />by Bera <br />nie <br />4.h <br />PX <br />300 <br />LO <br />O <br />N <br />O, <br />N <br />o <br />O <br />N <br />0 <br />N <br />Q <br />N <br />N <br />Q <br />M <br />N <br />0 <br />r` <br />O <br />N <br />r <br />O <br />N <br />O <br />r <br />O <br />N <br />O <br />N <br />N <br />I <br />O <br />Z <br />O <br />.-*. <br />r <br />O <br />O <br />O <br />i <br />' <br />O <br />NLO <br />W <br />w <br />o <br />a <br />o <br />0 <br />0 <br />0 <br />° <br />> <br />,- I <br />c� <br />ri <br />-i <br />psi <br />co <br />I <br />_I <br />Z <br />W <br />z <br />Qw <br />O }, <br />W <br />Z <br />O <br />^ <br />WOO <br />U <br />U c) <br />i1 <br />� <br />O <br />0Zj <br />or� <br />Q <br />z-� <br />w Q <br />LU <br />N <br />(D <br />��w <br />[V <br />Zo= <br />W <br />a <br /><�=) <br />0 <br />zwo <br />z <br />U <br />gzU- <br />az <br />z <br />�� <br />U <br />J <br />O 0 <br />W <br />z <br />A6� <br />Z <br />z <br />W <br />J <br />0 <br />N <br />LAST PLOT DATE <br />• <br />March 31, 2023 <br />O <br />2ND FLOOR <br />J <br />ELECTRICAL PLAN A, <br />B, K, L&M) <br />