My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6230 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6230 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 12:52:04 PM
Creation date
2/19/2025 8:21:23 AM
Metadata
Fields
Template:
Building Plans
Street #
6230
Location
Back Forty Lp
Contractor
Lennar Home
Building Plans - Permit #
6280
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS -WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST S FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />SECOND FLOOR ELECTRICAL PLAN (ALL ELEVATIONS) <br />1 /411 = 1'-011 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />19 <br />SWITCH- <br />4 1/2" <br />DOORJAMB <br />DUPLEX <br />OUTLET <br />TRIM <br />o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />kl-'SMOKE DETECTOR <br />1'-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />IHORIZONTAL <br />AT 12" - TOP PLUG IS HOT <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />69 SWITCH AT 36" <br />6i 3 WAY SWITCH AT 36" <br />-64-1 4 WAY SWITCH AT 36" <br />-o PUSH BUTTON FOR GARAGE DOOR OPENER <br />—o DIMMER SWITCH AT 36" <br />-� PUSH-BUTTON DOORBELL <br />-£A} CLG MNT LT FIXTURE <br />-{t} CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />{ WALL MNT FIXTURE <br />NOTE: <br />1 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />50W MR16 4" LOW VOLTAGE OWNER <br />) 50W PAR20 NFL 4" MINI ROUND RECESS <br />,oil 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />1 - CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />Cs SMOKE DETECTOR <br />C SMOKE DETECTOR <br />CU-182 UNDER CABINET 18" <br />CS-182 SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />= D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />® 48"CLG MNT WRAPPED FLUOR LIGHT <br />97-24;;g 24" VANITY LIGHTING <br />F;7uF 36 :7mR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />(% EXHAUST FAN <br />p� DOUBLE FLOOD LIGHT W/ COVERS AND <br />ti 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />= MASTER STATION <br />I§Fm;l ELEC PANEL <br />® VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />E3 A/C REGISTER <br />(1)i THERMOSTAT <br />OB SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />W %. -C 'O U <br />m N <br />m:0 <br />N <br />U <br />M <br />4) ::) O c o <br />g) 5 M s Q <br />N <br />00 E� <br />L m <br />LLI <br />w <br />�WW J O <br />OQ <br />J Q <br />QCY K0�QQ <br />o<Z-6YO08ZZp�cn <br />Oc�J¢oOU <br />U)O <br />Z¢ <br />jw 5LL¢aCQW_�0W_�oVZW_w <br />z <br />�¢°ad <br />LL <br />¢Ow 2 -I.- W0 <br />b p SQZ <br />a <br />Om <br />LL.¢ O H�Il <br />S <br />O <br />O <br />ZW <br />OF__ <br />(D) ti <br />M O <br />z <br />0 <br />Q � M � <br />W <br />LLz <br />W <br />ti <br />< W < <br />c+M <br />O <br />0 <br />Z <br />Z��, <br />W <br />w� <br />J <br />O <br />d' <br />Y <br />2011 <br />Virtual <br />Re <br />Fiew <br />Si <br />t Ir <br />C. <br />Plans Review c <br />pl <br />ted <br />nd <br />p r <br />e <br />r compliance wit <br />the <br />02 <br />FCC <br />7th <br />Edit* <br />n <br />by Debra A <br />ne <br />later <br />PX2 <br />0d <br />O <br />O <br />O <br />O <br />O <br />O <br />O <br />N <br />O <br />N <br />O <br />Co <br />MQjQQ <br />O <br />N <br />N <br />O <br />N <br />N <br />i <br />O <br />z <br />O <br />Co <br />.- <br />O <br />O <br />O <br />' <br />O <br />N,^ <br />w <br />CD <br />O <br />O <br />o <br />O <br />O <br />� <br />M <br />Cr <br />w <br />() <br />Qz <br />w <br />O <br />W <br />Z Co <br />000 <br />O <br />V <br />UV(p <br />Lo <br />Or< <br />-� <br />Q <br />Z—a <br />Q <br />F-Fw <br />N <br />w <br />zo= <br />■ <br />W�� <br />CL <br />O <br />U <br />zwo <br />wLL <br />:5W LL <br />QZ <br />F <br />pV <br />ow <br />J <br />W <br />z <br />'W <br />w <br />W <br />J <br />h <br />N <br />LAST PLOT DATE <br />• <br />March 23, 2023 <br />O <br />2ND FLOOR <br />ELECTRICAL PLAN <br />ABKL&M <br />