My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6230 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6230 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 12:52:04 PM
Creation date
2/19/2025 8:21:23 AM
Metadata
Fields
Template:
Building Plans
Street #
6230
Location
Back Forty Lp
Contractor
Lennar Home
Building Plans - Permit #
6280
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A/C <br />DIS( <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATIONS A & B <br />1 /411 = 1'-0„ <br />LEC <br />IETER <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PUP.POSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dyer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />�4 <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET io <br />TRIM o <br />c> <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />Qz <br />SC—SMOKE DETECTOR <br />MIN. <br />11 <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />HORIZONTAL <br />AT 12" - TOP PLUG IS HOT <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />6 STRUCTURED WIRE OUTLET <br />be SWITCH AT 36" <br />co <br />3 WAY SWITCH AT 36" <br />-64-1 4 WAY SWITCH AT 36" <br />-.0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />--a DIMMER SWITCH AT 36" <br />J0 PUSH-BUTTON DOORBELL <br />{A} CLG MNT LT FIXTURE <br />-�- CLG MNT PREWIRE - FIXTURE BY OWNER <br />-- SURFACE MNT FIXTURE <br />-} WALL MNT FIXTURE <br />NOTE: <br />TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />`_- APPROVED BY <br />Cl 50W MR16 4" LOW VOLTAGE OWNER <br />`Cl 50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-} CLG FAN PREWIRE AND SWITCH <br />COMBINATION <br />CARBON MONOIXED DETECTOR/ <br />COS SMOKE <br />0si SMOKE DETECTOR <br />rU-182 UNDER CABINET 18" <br />CS-182 SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />c S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />tm 24 ;:R 24" VANITY LIGHTING <br />FR;F36;;;;R 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />Q EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />�p DOUBLE FLOOD LIGHT W/ COVERS AND <br />ti 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />Z3 ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />8 A/C REGISTER <br />(TJ THERMOSTAT <br />M SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />W L .r'0q U <br />M 0 <br />IMF M2 <br />*- � M <br />4— <br />N - <br />V -80M <br />4) E- <br />�_ ors �� <br />.Ns way <br />■ QN C <br />L OCO <br />/* <br />WUZ <br />�WW QW Uw 0 <br />Wu-W�_0Mmv0 <br />(Q)r <br />? <br />0-�jo3�-dz�zmoF-Q <br />)oog oOOE00mzz <br />O <br />O <br />wwLLCr< <br />cn0z�zo__�WO <br />Wz�w�QOQza.¢ <br />M <br />H� <br />0Q zLL 0OC3� <br />�¢w <br />O <br />CN <br />Z <br />OF_ <br />(-1)5 � <br />O �_7 M C)Q U M L) <br />Ln <br />F-WtlM <br />Ira2v- <br />V< <br />Z <br />W <br />W <br />_j0 <br />(0 <br />�2203 <br />Vi <br />Plans Re <br />for comPlian <br />ual <br />ew <br />evi <br />°� <br />w A <br />lef'e <br />silt. <br />A <br />Inc. <br />apP <br />by 0 <br />a ih <br />wth <br />ra <br />nne <br />20 <br />OF <br />C7t <br />e <br />Edi <br />ion <br />I <br />Klah <br />Ip <br />PX <br />I <br />300 <br />o <br />0 <br />O <br />0 <br />0 <br />N <br />0 <br />M <br />0 <br />O <br />0_D <br />0 <br />0 <br />p <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />' <br />Z <br />O <br />N <br />0 <br />e- <br />0 <br />N <br />0 <br />M <br />0 <br />'V' <br />0 <br />6 <br />0 <br />CO <br />LO <br />M <br />z <br />W <br />(� <br />"i <br />Q <br />CDW <br />Zw <br />moo <br />O <br />V <br />UVm <br />LO <br />O <br />ova <br />Q <br />Z <br />= <br />a —a <br />W Q <br />� <br />mitW <br />N <br />zzom <br />W <br />� <br />al�-� <br />Q <br />0 <br />U <br />zCto <br />gZLL <br />u_ <br />Z <br />Z <br />U)z <br />OU <br />Q <br />W <br />z <br />z <br />W <br />w <br />J <br />r <br />LAST PLOT DATE <br />N <br />Z <br />. . <br />A. -a <br />0 <br />March 23, 2023 <br />J <br />1 ST FLOOR <br />ELECTRICAL PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.