Laserfiche WebLink
SHINGLE ROOF <br />7/8" STUCCO <br />OVER PLYWOOD---, <br />1 1/4" THK x 6" <br />STUCCO BAND---_ <br />SIMILAR <br />5/8" STUCCO <br />OVER CMU— <br />12 <br />5(— <br />■ <br />FRONT ELEVATION A <br />, 1 /411 = 1'-011 <br />REAR ELEVATION A <br />1 /411 = 11-011 <br />STUCCO CASING BEAD WITH <br />WEEP HOLES OVER FLASHING <br />VGLE ROOF <br />ELEV AT 8'-0" <br />T.O.M. <br />5/8" STUCCO <br />OVER CMU <br />ELEV AT 0'-0" <br />1ST FLOOR FF <br />ROOF FINISH <br />PER ELEVATION <br />ROOF SHEATHING <br />12 <br />5 MANUFACTURED <br />ROOF TRUSS <br />MTL DRIP EDGE <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />5� OVERHANG DETAIL <br />-nil <br />ROOF FINISH PER <br />ELEVATION <br />ROOF SHEATHING <br />> <br />MANUFACTURED <br />ROOF TRUSS <br />METAL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINIUM WRAP <br />PER ELEVATION <br />ALUMINUM <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />OVERHANG DETAIL <br />6 <br />a =77v <br />_ ELEV AT 8'-0" <br />T.O.M. <br />3'-0" <br />5/8" STUCCO <br />OVER CML12 <br />�o <br />Zo <br />ELEV AT 0'-0" Adk <br />- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1ST FLOOR FF <br />3 RIGHT ELEVATION A <br />1 /4 = 11-011 <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />LEFT ELEVATION A <br />1 /411 = 11-011 <br />12 <br />—15 <br />_ ELEV AT 8'-0" <br />T.O.M. <br />Z8" <br />STUCCO <br />OVER CMU <br />2 <br />00 <br />CD <br />ELEV AT 0'-0" <br />1 ST FLOOR FF <br />1'4' <br />1" <br />N <br />C0 <br />CD <br />FOAM BAND <br />5/8" STUCCO <br />FINISH <br />NOTE: <br />FOAM TO BE USED ONLY WHEN <br />REQUIRED BY COMMUNITY <br />SPECS. IF NOT, DETAIL TO BE <br />BUILT W/ STUCCO <br />VARIES PER OPENING of <br />1 2 I I 2" THICK <br />I I 1-1/2" THICK <br />N 3 1/2" <br />n <br />f� <br />3" THICK <br />VARIES PER OPENING <br />FOAM BAND 8 ELEVATION DETAILS <br />pia _ 1 1-Mv, <br />- CMU COLUMN DETAIL <br />3/4" = 1'-0" <br />4" 10" <br />N 4" <br />2 LB EPS 2" 1" <br />BRACKET DETAIL <br />CV <br />M <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM, <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />* EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />M <br />N <br />0 <br />rn <br />r <br />Li <br />ri i? <br />00 <br />Ln <br />U. <br />a, <br />a>, <br />' i'q` <br />�, Fey <br />z <br />w <br />�p--A yy <br />v�,� <br />O <br />z <br />Q <br />N <br />> <br />W L `a U <br />CO co <br />in <br />U 0 m u P <br />n' EL t0 <br />W2-2 ` O <br />o - a� a <br />—Z <br />•N <br />U�� <br />U W Qry <br />Q� <br />700 <br />L co � C6 <br />a� <br />W <br />❑w 0, wp1- <br />L w w w�FO <br />�73 0 O�LL0oL�o <br />00of 0 <br />z20Q oa�§Zw <br />QILU)O <br />Z¢�¢owQZWZ <br />w- w22mom9 <br />�0 <br />wrw��Uo <br />nr <br />m <br />LL <br />pw __YZQQ <br />00� 0 Z) 0QQW <br />Q <br />LLQ o Fw <br />If <br />O <br />O <br />Z W <br />O� <br />:ti <br />� M O <br />QWcor- <br />� (/5 <br />z <br />W < Ln <br />I— W M_ <br />0- <br />Z U <br />W <br />W <br />o <br />O <br />m <br />d' <br />21223 <br />Virtual <br />evi <br />w Assist <br />Inc <br />!, <br />Plans <br />Review <br />om <br />lete <br />an <br />ape <br />r� <br />for compliance <br />th t <br />ell <br />14 FBq <br />7 <br />E <br />itio <br />Debra <br />A <br />' <br />Mby <br />W <br />N <br />N <br />N <br />N <br />o <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />r <br />W <br />M <br />O <br />N <br />co <br />N <br />i <br />I <br />O <br />0 <br />0 <br />� <br />o <br />I <br />f <br />Z <br />0 <br />N <br />0 <br />LO <br />Lo <br />W <br />> <br />g <br />r <br />o <br />N <br />M <br />0 <br />�i' <br />o <br />Lo <br />I <br />i <br />I <br />zZ <br />U) <br />Qz <br />O <br />zw <br />-� <br />0 <br />0 <br />W <br />U <br />WOO <br />U V � <br />L <br />F- <br />::)zj <br />/ <br />.Q <br />Z <br />O�0 <br />a�a <br />Q <br />C) <br />= <br />w=¢ <br />0 <br />I--~O <br />z6c=n <br />W <br /><!� <br />..� <br />Ogwo <br />U <br />z <br />�z <br />�z <br />Z <br />�� <br />0U <br />0 <br />W <br />z <br />A5 <br />z <br />z <br />w <br />W_jW <br />CD <br />M <br />N <br />O <br />N <br />LAST PLOT DATE <br />June 19, 2023 <br />z <br />0 <br />J <br />EXTERIOR <br />ELEVATIONS A <br />