My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6453 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6453 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 8:04:47 PM
Creation date
2/19/2025 8:23:34 AM
Metadata
Fields
Template:
Building Plans
Street #
6453
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
II\ <br />GFI GFIPANT14RY " <br />o <br />AV- <br />GFIN. <br />GFI AT TV <br />r I 30" A.F.F. ��`/VC�� <br />if <br />GFI HDMI <br />TO_" <br />DISP -16 <br />`- <br />GF LIVING ROOM <br />G F JTFi <br />30A.F <br />I <br />4'-3" 5'-8" <br />GFI KITCHEN <br />6'-0" <br />A <br />G F <br />GFI <br />A / <br />GFI -10' <br />DINING <br />TILIT ROOM W F I-0. <br />14b F <br />GFI \ PW_DR\ <br />C7�, <br />BATH J <br />ELEC O <br />METER 2'-11 3/4" <br />ELEC <br />PANEL <br />1 i <br />! TWO CAR GARAGE ,• <br />1 I <br />48 GFI o <br />CS TO 2N FI <br />CV <br />GFI FLR ELEC <br />110V CLG i <br />MNT. <br />_---OUTLET ---! — <br />N / 3 <br />o <br />I <br />I 4 I GFI 1 <br />N WP 1 <br />I 4'-$„ 1 <br />I ! I <br />ENTRY <br />L--------------------� <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION A <br />1 /411 = 1 1-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN, <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE, <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES, <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.1. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017, <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH--,— <br />SWITCH- <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ <br />S <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />a TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />QSTRUCTURED WIRE OUTLET <br />6- SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />-64-1 4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />--� PUSH-BUTTON DOORBELL <br />{A} CLG MNT LT FIXTURE <br />{B} CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />{ WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />USEDIF <br />C 50W PAR30 NFL 6" WHITE BAFFLE APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />O- 50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBAL <br />{} CLG FAN PREWIRE AND SWITCH <br />COS COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />C SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />= U-36 = UNDER CABINET 36" <br />= S-36 = SINGLE 36" FLUOR STRIP <br />= D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48— DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />9F24:;;g 24" VANITY LIGHTING <br />FFFF 36 :F;R 36" VANITY LIGHTING <br />48� 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUSTFAN <br />p DOUBLE FLOOD LIGHT W/ COVERS AND <br />C: 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />fM CHIMES (DELETE W/ INTERCOM) <br />1= MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />E3 A/C REGISTER <br />OT THERMOSTAT <br />On SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />tno, <br />N LO - <br />'0 <br />W <br />L N U <br />12 c7 _ ai <br />CO 00 <br />4 <br />to <br />::) i) M U a <br />V -U � 2 2 M <br />�} <br />E <br />41 .E �o <br />0 O o D Q <br />-�°', < <br />^` <br />610 <br />QN C <br />o0 <br />W <br />7C0 <br />:r E <br />�0aa <br />V, <br />Uj <br />❑L <br />�WOLU �W F-Q D _j o:gzF x <br />°��(D o�o° <br />Q <br />E- <br />°LzEooWoo�_<<H <br />mZ <br />= <br />ow�Z <br />0 W W Q� <br />pWZWZO <br />5Oz <br />U- <br />�QO�o¢ <br />O W �I-� �YZQQ <br />aoU <br />Q <br />C 0 ❑ ❑Q � <br />WQ o �QW <br />i� <br />O <br />O <br />Z (N <br />O� <br />.,,(/) f ti <br />0 <br />p j_:C0 <br />Q u) CO � <br />z <br />I-0111M <br />� � 00 <br /><� <br />V <br />Z <br />W <br />W <br />J O <br />O <br />m _ <br />\/7 <br />/ <br />J <br />L <br />. __' <br />2 11 <br />2 <br />, <br />23 <br />Virtual Revi <br />w A <br />sis <br />. the <br />1 <br />Plans Review co <br />letad <br />a <br />dap <br />rav <br />d <br />compliance with <br />e 2,12 <br />0 <br />BC <br />th <br />' io <br />by Debra An <br />Kl <br />h& <br />I <br />X�3 <br />I <br />0 I <br />I <br />T— <br />o <br />0 <br />0 <br />0 <br />LO <br />0 <br />N <br />0 <br />N <br />N <br />N <br />N <br />O <br />C)r <br />O <br />N <br />O <br />N <br />r <br />N <br />' <br />C) <br />z <br />o <br />0 <br />0 <br />C)I <br />' <br />O <br />N Lo <br />W <br />o <br />o� <br />o <br />0 <br />o <br />I <br />LO <br />> <br />N <br />M <br />cf <br />Lo <br />CO <br />i <br />� <br />Mf <br />Z� <br />Z <br />W <br />Z <br />w <br />C)A- 0 <br />�� <br />W <br />Z <br />z <br />® <br />_ <br />WOO <br />U <br />U U <br />I— <br />O <br />oz> <br />01w- 0 <br />Z <br />0- ai a- <br />I— <br />�w< <br />= <br />mTw <br />tV <br />o?o <br />N <br />SOU) <br />w <br /><F-Z) <br />0 <br />ZWO <br />� O <br />Z <br />C) <br />Z u_ <br />• <br />az <br />Q <br />F� <br />U <br />_j <br />O <br />o- <br />MMO <br />W <br />tY <br />z <br />z <br />z <br />w <br />W <br />0 <br />0 <br />LAST PLOT DATE <br />• <br />May 8, 2023 <br />� <br />ZO <br />1 ST FLOOR <br />ELECTRICAL PLAN A <br />
The URL can be used to link to this page
Your browser does not support the video tag.