GND <br />1 <br />DISPENSER #1 BREAKER <br />WIRE TROUGH <br />® KEY NOTES <br />,Lj <br />F <br />TO SITE GROUND <br />ELECTRODE <br />RUL STP #1 <br />BREAKER <br />0 0 <br />0 0� <br />0 <br />t <br />EMC PO <br />P1 <br />10 <br />0 <br />PUL STP <br />QornvMo <br />tSTP 11 <br />2 <br />i- <br />PO <br />EMC P1 <br />10 <br />7 <br />DSL STP #3 <br />BREAKER <br />8 <br />O� <br />Fil STP 11 <br />3 T: <br />PO <br />EMC P1 <br />10 <br />El I EMERGENCY POWER <br />CUTOFF <br />LOAD CENTER <br />120 VAC <br />Ll OrSINGLE <br />60 HZ <br />GILBARCO STP ISOLATION BOX-#1 <br />PA0287 <br />L1 <br />TB1-1 <br />N <br />TB2-1 <br />TB1-2 <br />L2 <br />TB2-2 <br />T61-3 <br />M 1 <br />TB2-3 <br />TB1-4 <br />M2 <br />TB2-4 <br />PO <br />TB1-5 <br />TB2-5 <br />P1 <br />TB1-6 <br />TB2-6 <br />TB1-7 <br />GND <br />TB2-7 <br />TB1-8 <br />TB2-8 <br />GILBARCO STP ISOLATION BOX42 <br />1 (DISPENSER <br />STP-1 (DIS <br />DISPENSER #2 BREAKER <br />DISPENSER #3 BREAKER <br />PA0287 <br />L1 <br />TB1-1 <br />N <br />TB2-1 <br />TB1-2 <br />L2 <br />TB2-2 <br />TB1-3 <br />TB2-3 <br />TB1-4 <br />TB2-4 <br />IPO <br />TB1-5 <br />TB2-5 <br />TB1-6 <br />TB2-6 <br />TB1-7 <br />GND <br />TB2-7 <br />TB1-8 <br />TB2-8 <br />GILBARCO STP ISOLATION BOX43 <br />NEUTRAL(D <br />DISPENSER #4 BREAKER <br />DISPENSER #5 BREAKER <br />L1 <br />TB1-1 <br />N <br />TB2-1 <br />TB1-2 <br />L2 <br />TB2-2 <br />TB 1-3 <br />M 1 <br />TB1-4 <br />M2 <br />TB2-4 <br />ETB2-3 <br />PO <br />TB1-5 <br />TB2-5 <br />P1 <br />TB1-6 <br />TB2-6 <br />TB1-7 <br />GND <br />TB2-7 <br />TB1-8 <br />TB2-8 <br />PENSER5 <br />DISPENSER 1 <br />PENSER6 <br />REAKER c <br />WIRING DIAGRAM FOR ISOLATION RELAY BOX <br />NTS <br />L1 (DISPENSER 1) 1� INSTALL A SINGLE EMERGENCY POWER CUTOFF <br />CONTROL TO REMOVE AC POWER FROM SITE <br />NEUTRAL (DISPENSER 1) ® DISPENSING EQUIPMENT. <br />GROUND (DISPENSER 1) (THE CONTROL IS AN ADDITION SAFETY FEATURE <br />AND NOT A SUBSTITUTE FOR NEC/NFPA30 c <br />STP-1 (DISPENSER 1) DISPENSER #1 CIRCUIT BREAKER REQUIREMENTS. O <br />STP-2 (DISPENSER 1) DIESEL a <br />STP-3 (DISPENSER 1) * LABEL THE EMERGENCY POWER CUTOFF <br />SWITCH AND INSTRUCT OWNER TO KEEP AREA a) <br />CLEAR OF OBSTACLES. 0 <br />�2. CONNECT INSULATED GROUNDING CONDUCTOR <br />FROM THE DISPENSER POWER PANEL TO THE <br />SITE GROUNDING ELECTRODE. SIZE PER NEC. <br />a� <br />3. INSTALL POWER BREAKERS TO EACH CIRCUIT <br />LEADING TO THE DISPENSING UNIT AND STP. <br />THEY MUST BE CAPABLE OF SIMULTANEOUSLY <br />DISCONNECTING HOT AND NEUTRAL <br />CONDUCTORS. N <br />❑4 REFER TO INSTALLATION ADDENDA FOR Proto 2nd Qtr 04-03-15 <br />SPECIFIC PRODUCT FIELD WIRING <br />CONNECTIONS. CAP ALL UNUSED WIRES. LOCAL <br />STP-1 (DISPENSER 2 <br />) AND NEC MAY APPLY. <br />STP-2 (DISPENSER 2) <br />® 5. INSTALL CONDUIT PER NEC FOR HAZARDOUS <br />DISPENSER #2 LOCATIONS. <br />L1 (DISPENSER 2) 6. WIRES -ALL WIRES ARE 14AWG (STANDARD) <br />NEUTRAL (DISPENSER 2) UNLESS OTHERWISE NOTED. PUMP / DISP. LO J <br />GROUND - WIRE IS 12 AWG (STANDARD). U � <br />GROUND (DISPENSER 2) J M <br />L1 (DISPENSER 3) POWER LOADING AND DISTANCE RUN MAY J J (V W <br />REQUIRE LARGER WIRE SIZE. LL L 0 <br />NEUTRAL (DISPENSER 3L ® 0- Q Cj' cn X <br />GROUND (DISPENSER 3) 7. NOT USED a co <br />STP-1 (DISPENSER 3) DISPENSER #3 O Q N m L m <br />STP-2 (DISPENSER 3) ❑8 STP ISOLATION RELAY BOXES ARE MANDATED N �. <br />BY THE NEC (ARTICLE 514.13 - PROVISIONS FOR LL J <br />MAINTENANCE AND SERVICE OF DISPENSING Q J <br />EQUIPMENT) AND ARE REQUIRED TO: Q 0 = uj <br />A. ALLOW SERVICE OF ONE UNIT SAFELY _04 <br />WITHOUT REMOVING POWER FROM ALL Z 1- U-) 1- Z <br />DISPENSING EQUIPMENT. Q r.. a 0 <br />B. PREVENT DAMAGE TO EQUIPMENT FROM W <br />CROSS -PHASING. W N <br />DAMAGE CAUSED BY CROSS -PHASING IS N 0 <br />NOT COVERED BY WARRANTY Lc" j <br />GILBARCO STP ISOLATION BOX PA0287 IS NOT <br />AVAILABLE FOR 220/230/240VAC UNITS. (THIS IS A <br />OWNER SUPPLIED ITEM.) <br />❑9 FOR STPs GREATER THAN 1-1/2HP (SINGLE OR <br />STP-1 (DISPENSER 4) THREE PHASE) CONNECT TO MOTOR <br />STP-2 (DISPENSER 4) ® CONTRACTOR COIL OF SEPARATE STP RELAY <br />BOX. <br />DISPENSER #4 10. L1 FEEDS STP BOX CONTRACTOR COIL, <br />L1 (DISPENSER 4) THEREFORE L1 & EMC MUST BE ON THE SAME <br />NEUTRAL (DISPENSER 4) PHASE OR DAMAGE TO EMC WILL RESULT. <br />GROUND (DISPENSER 4) WHEN EMC IS NOT USED, JUMPER STP BOX <br />L1 (DISPENSER 5) TERMINALS PO AND P1 TOGETHER TO COMPLETE <br />THIS CIRCUIT. <br />NEUTRAL (DISPENSER 5) <br />GROUND (DISPENSER 5) ® 11. V.F.C. or STP C.B.S. <br />STP-1 (DISPENSER 5) DISPENSER #5 <br />STP-2 (DISPENSER 5) <br />d. <br />La <br />0 <br />imm <br />W U) <br />n <br />0 <br />STP-1 (DISPENSER 6) ' c o <br />STP-2 (DISPENSER 6) <br />❑ O Vl ar STP-3 (DISPENSER 6) Of 01 4 � a <br />DISPENSER #6 <br />L1 (DISPENSER 6) w a <br />DIESEL <br />NEUTRAL (DISPENSER 6) cfl (0 Y U) <br />GROUND (DISPENSER 6) C)UJI V <br />o O <br />00 Z o <br />w <br />a m <br />U) m <br />w o o v <br />o���0=owom=oE <br />o c« c WS0 a <br />Tu�a�.t�3ocT°�a°ia'�u, <br />°ro°.- w-.�aNtov,uo, <br />°toh3Q o <br />a v; 4) ICU <br />N a� CL'o (w O U C Nt <br />a,o�'cuC'°'�.3�la�' <br />_v <br />aDwao-o..o of <br />7++ N—�EW-0N,_r <br />0�VL W0 <br />'O.>,T 0) N O C Q M AO C O C Q."> >,O+ <br />0m9 oVt3'-(n <br />,,,1111111#off,,I <br />FERG! <br />.j..•�C'E'Ns'•. <br />fi, <br />SHEET: <br />Gll <br />w- <br />FUELING - USA <br />