Laserfiche WebLink
NON -HAZARDOUS AREA <br />HAZARDOUS AREA <br />GENERAL NOTES <br />AC LINE <br />AC NEUTRAL <br />CHASSIS GROUND <br />BARRIER GROUND <br />RIGID CC <br />O <br />® <br />(90 <br />N L <br />0 ® o <br />„�. <br />@) 00 <br />• <br />• <br />Ethernet/Phone line <br />Communications <br />• Compartment <br />• <br />• <br />• <br />• <br />• <br />• <br />RE <br />RS232 TO ISP <br />BIR CABLE T. , ". <br />GAS CONTROLLER <br />REFER TO THE OWNERS VEEDER ROOT INSTALLATION <br />PROTOCOL GUIDE FOR SET UP AND CONFIGURATION OF <br />REMOTELY MONITORED VEEDER ROOT EQUIPMENT. <br />RIGID <br />CONDUIT <br />TABLE 1 <br />CABLE TYPE <br />BELDEN 88760 <br />12 AWG THWN <br />CONTRACTOR SHALL PLACE A TYPEWRITTEN SENSOR <br />SCHEDULE THAT INDICATES WHICH CHANNEL IS <br />ASSOCIATED WITH WHICH SENSOR <br />SITE MONITORING WIRING SCHEMATIC <br />1 1 1/2"=1'4' <br />I�1,ZP1>;i�i1C�]PlaR:l3►�1��1 <br />"Allll <br />Probe <br />11 B11 <br />Non-Disciminating <br />Sump Sensor <br />(Containment) <br />=R CABLE JACKET <br />TO <br />MONITOR <br />SEALANT <br />PACK <br />UTS <br />IS <br />POS <br />RJ45 CATEGORY <br />PATCH 5CABLE <br />CORD <br />ROUTER HUB <br />TO FRAME RELAY <br />TELEPHONE LINE <br />ISP CABLE WITH KIT <br />ADAPTER #330020-409 <br />NOTE: <br />ISP <br />ATG <br />TS-1000 <br />CABLE <br />BOX <br />PASSPORT <br />GAS <br />CONTROLLER <br />1. HUB, ROUTER AND CABLES BY NCR INSTALLER <br />2. PASSPORT GAS CONTROLLER, D-BOX, CRIND CONTROL CABLE, <br />GAS CONTROLLER CABLE AND D-BOX CABLE INSTALLED BY THE <br />GILBARCO AUTHORIZED SERVICE CONTRACTOR <br />D-BOX <br />"Y" CABLE & 2 9-PIN "D" <br />STYLE CONNECTORS <br />2POS GAS CONTROLLER DIAGRAM <br />NTS <br />DUPLEX RECEPTACLE <br />LIB <br />TA <br />PAIRED GASOLINE <br />CABLE IN TRENCH TO <br />GASOLINE DISPENSERS <br />GASOLINE DISPENSER <br />DATA DISCONNECT <br />DEVICE <br />IMPORTANT: THIS IS A CONTROL <br />DRAWING ONLY AND DOES NOT <br />REFLECT THE ACTUAL LOCATIONS <br />OF CONDUIT ENTRY (SEE NOTE 7 <br />BELOW). <br />VEEDER-ROOT REQUIRES THAT ANYONE INSTALLING OUR <br />EQUIPMENT MUST BE LEVEL I CERTIFIED. FOR MORE <br />INFORMATION REGARDING THE HOME STUDY INSTALLERS <br />COURSE CONTACT JOHN HOWELL 951-532-8599. <br />WARNING: IN INSTALLATION AND USE OF THIS <br />PRODUCT, COMPLY WITH THE NATIONAL <br />ELECTRICAL CODE; FEDERAL, STATE AND LOCAL <br />CODES. IN ADDITION, TURN OFF POWER AND TAKE <br />OTHER NECESSARY PRECAUTIONS DURING <br />INSTALLATION, SERVICE AND REPAIR TO PREVENT <br />PERSONAL INJURY, PROPERTY LOSS AND <br />EQUIPMENT DAMAGE. <br />WARNING: DISCONNECT ALL POWER BEFORE <br />MAKING ANY CONNECTIONS TO PREVENT DEATH, <br />SERIOUS INJURY, EXPLOSION, OR ELECTRICAL <br />SHOCK. MONITOR MUST NEVER BE OPERATED <br />UNLESS THE FRONT COVER IS CLOSED OVER THE <br />BARRIER TERMINALS IN THE INTRINSICALLY SAFE <br />AREA. <br />' 1. INTRINSICALLY SAFE WIRING <br />" BONDED CONDUIT MEANS THAT THE <br />METALLIC <br />SECTIONS OF CONDUIT ARE P PERMANENTLY <br />JOINED TO FORM AN ELECTRICALLY <br />CONDUCTIVE PATH THAT WILL ASSURE <br />ELECTRICAL CONTINUITY, AND THAT THE <br />CONDUIT HAS THE CAPACITY TO CONDUCT <br />SAFELY, ANY CURRENT LIKELY TO BE IMPOSED. <br />a) BONDED & NON -BONDED CONDUIT - THE <br />WIRES BETWEEN THE MONITOR AND EACH <br />PROBE/SENSOR LOCATION MUST BE #14, #16 OR <br />#18 AWG STRANDED COPPER WIRES <br />WITHIN A SHIELDED CABLE. SHIELDED CABLE <br />MUST BE RATED AT LESS THAN 100 <br />PICOFARAD PER FOOT AND MUST BE <br />MANUFACTURED WITH A MATERIAL SUITABLE <br />FOR THE ENVIRONMENT, SUCH AS BELDEN TM <br />88760. <br />2. CONNECT THE BARRIER GROUND TO THE <br />EARTH GROUND BUS AT THE POWER <br />DISTRIBUTION PANEL WITH #12 AWG (OR <br />LARGER) CONDUCTOR. <br />3.O DENOTES FIELD WIRING CONNECTION USING <br />WATERPROOF CONNECTORS SUPPLIED WITH <br />THE PROBE(S) AND SENSOR(S). <br />4. INTRINSICALLY SAFE WIRING SHALL BE <br />INSTALLED IN ACCORDANCE WITH ARTICLE <br />504-20 OF THE NEC, ANSI/NFPA 70. <br />5. TO MAINTAIN INTRINSIC SAFETY, <br />PROBE/SENSOR WIRING MUST BE INSTALLED <br />WITH EITHER SEALED CONDUIT OR DIRECT <br />BURIAL METHODS. REFER TO "DIRECT <br />BURIAL CABLE INSTALLATION", MANUAL NO. <br />576013-858. <br />6. ELECTRICAL RATING POWER INPUT 120 VAC, <br />50/60 HZ, 100 VA MAXIMUM. <br />7. THIS DOCUMENT IS NOT TO BE USED AS A <br />SUBSTITUTE FOR SPECIFIC EQUIPMENT <br />INSTALLATION MANUALS. FOR INSTALLATION <br />DETAILS USE THE RESPECTIVE MANUAL: <br />TLS-350(R) 576013-879 <br />8. ALL CABINET PENETRATIONS MUST ENTER <br />THROUGH A PRE -DRILLED CONDUIT <br />KNOCKOUT. <br />Z <br />w <br />c � <br />o O <br />U w <br />0 5 <br />o W <br />w <br />w <br />a <br />Proto 2nd Qtr 04-03-15 <br />U0 <br />0 <br />J M <br />J <br />LL <br />O0-NQ <br />L.L ~ <br />(1� W <br />Q <br />Z <br />Q H <br />0 M <br />W <br />N <br />M <br />N <br />LO <br />M <br />Cn <br />0>J <br />NmILL <br />r <br />QJ <br />N <br />�� <br />~' � <br />a <br />N <br />O <br />Y <br />cA <br />U <br />o <br />H <br />rn <br />o <br />O <br />M <br />Z <br />O <br />U) <br />Q <br />m <br />W <br />N <br />CDm <br />5 <br />Co <br />p <br />M <br />L <br />c) <br />0 <br />0 <br />U <br />m �^ <br />00MRii=000, c 0M <br />U N •• >,`� � c o v <br />U o <br />ha2o3oc��n�c n� <br />oso�n_aoyu, <br />N$a02�=00 0 Nw <br />cTE3:,5 30o'��3�0 <br />ao- nwtE(COL 9ccmtas <br />_2a)u4niaE_-d.wpoZ _oE <br />0) �� ELM')) 9- �� <br />Ewo,200,6u(045t �U <br />j:j E a—.2 X'Ut 3'cin <br />.. <br />SHEEG12 <br />FUELING - USA <br />