My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6603 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
6603 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:12:09 PM
Creation date
2/19/2025 8:25:21 AM
Metadata
Fields
Template:
Building Plans
Street #
6603
Location
Gall Blvd
Contractor
SL2 Consulting
Building Plans - Permit #
3675
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL PLUMBING NOTES: <br />GENERAL <br />I. THE BUILDING SHALL BE PROVIDED WITH THE FOLLOWING SYSTEMS: <br />A. A COMPLETE COLD WATER AND HOT WATER SYSTEM. <br />B. A COMPLETE SANITARY, WASTE AND VENT SYSTEM. <br />2. MANUFACTURERS AND MODEL NUMBERS SHOWN IN THE CRITERIA ARE USED <br />AS A BASIS OF DESIGN. WITH OTHER APPROVED MANUFACTURERS NOTED. <br />SUBSTITUTION FOR THE BASIS OF DESIGN ITEMS IS SUBJECT TO THE <br />WRITTEN APPROVAL OF THE ARCHITECT ON AN APPROVED EQUAL BASIS <br />WATER PIPING <br />I. WATER PIPING SHALL BE TYPE 'L' COPPER, WITH 95-5 SILVER SOLDERED <br />JOINTS.CPVC MAY BE USED AS AN ALTERNATE <br />2. INSULATE ALL HOT WATER PIPING WITH I' RIGID FIBERGLASS OR �y2' <br />FLEXIBLE FOAM INSULATION (ARMAFLEX). FLEXIBLE FOAM INSULATION <br />SHALL NOT BE SPLIT, AND SHALL BE TAPED AT THE BUTT JOINTS. <br />3. PROVIDE EACH FIXTURE WITH STOPS AND SUPPLIES. EXPOSED STOPS <br />SHALL BE CHROME PLATED. <br />4. PROVIDE WATER HAMMER PROTECTION AT EACH FIXTURE, OR GROUP OF <br />SIMILAR FIXTURES. <br />5. PROVIDE VACUUM BREAKERS AS REQUIRED BY CODE. <br />6. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS. PRIMERS SHALL BE <br />LOCATED IN A SERVICEABLE LOCATION. <br />7. STERILIZE WATER PIPING IN ACCORDANCE WITH THE HEALTH DEPARTMENT <br />REGULATIONS AND AMERICAN WATER WORKS ASSOCIATION'S SPECIFICATIONS. <br />SANITARY PIPING <br />1. SANITARY, WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC, UNLESS <br />PROHIBITED BY THE LOCAL CODES. <br />2. IF PVC PIPING IS PROHIBITED UNDER -GROUND, BY THE LOCAL CODES, <br />THEN SANITARY WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT <br />CAST IRON. LEADED JOINTS. TYLER 'TY-SEAL' AND 'NO -HUB' ARE <br />APPROVED SUBJECT TO APPROVAL BY THE BUILDING OFFICAL. <br />3. IF PVC PIPING IS PROHIBITED ABOVE -GROUND BY THE LOCAL CODES, <br />THEN SANITARY, WASTE, AND VENT PIPING SHALL BE SERVICE WEIGHT <br />CAST IRON. LEADED JOINTS, TYLER 'TY-SEAL' AND 'NO -HUB' ARE <br />APPROVED SUBJECT TO APPROVAL BY THE BUILDING OFFICIAL. <br />4. AN APPROVED ALTERNATE FOR ALL SANITARY, WASTE AND VENT PIPING <br />IS DWV COPPER WITH 50-50 TIN LEADED SOLDERED JOINTS. <br />5. SLOPE OF SANITARY AND WASTE PIPING SHALL BE 1/4' PER FOOT MINIMUM. <br />6. EXPOSED WASTE DRAINS, IN TOILETS, SHALL BE CHROME PLATED <br />BRASS, WITH MATCHING STOPS AND ESCUTCHEONS. <br />7. ROOF PENETRATIONS SHALL BE WITH LEAD PIPE ROOF JACKS. <br />PLUMBING KEYNOTES <br />Oi 4' SAN SEWER STUB -IN LOCATION <br />O2 NEW ADA TOILET ROOM WITH <br />FLOOR DRAIN <br />O ADA WATER FOUNTAIN <br />ONEW 3/4' SUPPLY LINE ABOVE WITH <br />S/OFF VALVE <br />WALL BRACKET <br />WATTS USB-B <br />TEMPERING VALVE <br />WALL BRACKET <br />POINT -OF -USE <br />WATER HEATER <br />WALL BRACKET <br />COLD WATER INLET <br />NOTESt <br />I. WATER TEMPERATURE LIMITING DEVICES SHALL BE USED AT <br />ALL LAVATORIES <br />2. DEVICES SHALL COMPLY WITH ASSE 1070 OR CSA BI25.3 <br />3. CONDITION AT EMPLOYEE TOILET ROOM IS SIMILAR <br />COLD <br />WATER <br />SUPPLY <br />TEMPERATURE LIMITING <br />rY DEVICE DETAIL <br />T14/NOT TO SCALE <br />NEW 4' <br />PLUMBING <br />WALL <br />EXISTING 2 HR TENANT <br />SEPARATION PARTITION <br />I� <br />LVI <br />EWC O <br />NEW 4• <br />PLUMBING WALL <br />DOC MI <br />SUITE 6603 <br />4' SAN SEWER - SEE CIVIL <br />PLANS FOR CONTINUATION <br />CO <br />NO SLAB IN THIS AREA <br />NEW 2 HR TENANT <br />SEPARATION PARTITION <br />I 3/4' CW ABOVE CEILING O <br />--4 <br />1.-- ---------------- - - - - - - -�'CW- - - <br />------------ [� h <br />-------------- ----------------I y <br />EXISTING I" CW UG FROM METER <br />AND BFP - SEE CIVIL <br />PLANS <br />PLUMBING SCOPE <br />I. CONSTRUCT ONE ADA COMPLIANT TOILET <br />ROOM AS SHOWN. <br />INSTALL ONE NEW HI -LOW ELECTRIC WATER COOLER <br />2. CONNECT NEW SANITARY SEWER LINES INTO <br />EXISTING WASTE LINES STUBBED INTO THE <br />BUILDING AS SHOWN <br />3. PROVIDE NEW CPVC WATER SUPPLY LINES TO <br />NEW FIXTURES AS SHOWN. SUPPLY FIXTURES <br />FROM EXISTING 2' WATER LINE WITH SHUT/OFF <br />VALVE STUBBED INTO THE BUILDING <br />4. FIELD VERIFY ALL EXISTING PLUMBING WASTE LINE <br />DEPTHS AND SUPPLY LINE SIZES. MAKE ADJUSTMENTS <br />AS NECESSARY AND AS PER PLUMBING CODE <br />NEW <br />3' VTR <br />A 3•V <br />3'V•4 2 1/2.0 <br />i 2 1/2'V- <br />i <br />I <br />WCI i FD 3'SS� <br />3'SS 3'SS <br />LVI <br />2 1/2'SS <br />EXISTING 3" <br />SANITARY <br />SEWER TO <br />UTILITY <br />3•SS <br />2 1/2'SS <br />EWC <br />1 WASTE RISER <br />�-, <br />NOT TO SCALE <br />some <br />Revisions Date By <br />MarkA onnatti <br />Florida AR 0010778 <br />JONNATTI <br />ARCHITECTURE <br />INCORPORATED <br />21021NS Highway 19 N <br />WHY Clea er, Florida 33765 <br />(727) 25-ARCH <br />(727) 725-2603 fx <br />PLUMBING <br />FLOOR PLAN <br />SCALE 1/8" = I'-0' <br />PLUMBING NOTES: <br />I. ALL PLUMBING WORK SHALL BE IN COMPLIANCE WITH THE 2020 FLORIDA BUILDING CODE.2020 <br />FLORIDA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES AND ORDINANCES. <br />2. GENERAL CONTRACTOR SHALL INCLUDE ALL WORK REQUIRED FOR A COMPLETE INSTALLATION <br />AND FOR PROPER OPERATION OF MECHANICAL AND PLUMBING SYSTEMS, INCLUDING ALL <br />WORK REQUIRED BY CODE OR REGULATORY AGENCIES. <br />3. SEE SHEET GI.2 FOR ADDITIONAL TOILET ROOM NOTES AND DIMENSIONAL INFORMATION <br />4. ALL PLUMBING FIXTURES SHALL COMPLY WITH FLORIDA BUILDING CODE 2020 401-426. PROVIDE <br />FIXTURE AND FAUCET COMPLIANCE WITH MAXIMUM WATER CONSUMPTION RATES PER <br />FLORIDA BUILDING CODE PLUMBING 604.4 <br />5. PROVIDE TEMPERED HOT WATER FOR ACCESSIBLE HAND WASHING LOCATIONS <br />PLUMBING LEGEND <br />CW <br />_ _ <br />NEW COLD WATER- <br />BALANCING VALVE <br />HW. <br />- - - <br />NEW HOT WATER <br />--J\-- <br />CHECK VALVE <br />WHY <br />WALL HYDRANT <br />-04- <br />GLOBE VALVE/BALL VALVE <br />HB <br />y+- <br />HOSE BIB <br />�- <br />IN LINE PUMP <br />-�I�- <br />UNION <br />-HWR - <br />HOT WATER RECIRCULATED <br />--{-- <br />GATE VALVE <br />-G <br />NATURAL GAS LINE <br />SOIL OR WASTE <br />BFG <br />BELOW FINISHED GRADE <br />- <br />- - - - - - <br />VENT <br />BFF <br />BELOW FINISHED FLOOR <br />CW- <br />EX►STG COLD WATER <br />AFC <br />ABOVE FINISHED CEILING <br />HW <br />EXISTG HOT WATER <br />ate- <br />P-TRAP <br />- <br />GL <br />GREASE LINE <br />SS <br />SANITARY SEWER <br />WHA_ <br />WATER HAMMER ARRESTOR <br />OM <br />WATER METER <br />FD <br />FLOOR DRAIN <br />C. <br />PIPE TURNED DOWN <br />FS <br />FLOOR SINK <br />! <br />PIPE TURNED UP <br />HD <br />ISC -- <br />HUB DRAIN <br />5--•- <br />END OF PIPE <br />FCO <br />*}- <br />FLOOR CLEANOUT <br />WH <br />WATER HEATER <br />COTG <br />CLEANOUT TO GRADE <br />0 <br />P-TRAP <br />WCO <br />ICf- <br />WALL CLEANOUT <br />CO <br />11 <br />END OF LINE CLEANOUT <br />• <br />WALL MOUNTED LAVATORY <br />VTR <br />VENT THRU ROOF <br />DRINKING FOUNTAIN <br />NTS <br />NOT TO SCALE <br />® <br />OR WATER COOLER <br />RWL <br />RAIN WATER LINE <br />l...WHY <br />WALL HYDRANT <br />Oo <br />TANK TYPE WATER CLOSET <br />PLUMBING FIXTURE SCHEDULE <br />SYMBOL <br />DESCRIPTION <br />MANUF. <br />MODEL NO. <br />CW <br />HW <br />WASTE <br />VENT <br />HEIGHT <br />MAX. WATER <br />COLOR <br />REMARKS <br />USAGE <br />FINISH <br />17'-19' AFF <br />BEMIS 3155CCST, (OR OTHER SLOW -CLOSE SEAT). SLOAN <br />WCI <br />HANDICAPPED <br />KOHLER <br />KOHLER <br />I/2" <br />3' <br />3' <br />COMPLY WITH <br />1.6 GPF <br />WHITE <br />FLUSHMATE M-101526-F3IPRESSURE ASSIST SYSTEM, <br />WATER CLOSET <br />OR EQUAL <br />K-3611 <br />ADA / ANSI <br />CHROME STOPS/SUPPLIES & LID LOCKS. <br />INSTALL PER ADA & ANSI-AlIT.I REOUIREMENTS <br />EWC <br />WATER COOLER <br />(TWO STATION <br />ELKAY <br />ELKAY <br />1/2' <br />i <br />2/2' <br />i <br />2/2• <br />COMPLY WITH <br />.25 GAL/MIN <br />STAINLESS <br />JR SMITH 0834RL FIXTURE SUPPORT CARRIER. <br />HI-LO) <br />OR EQUAL <br />LZSTLBLC <br />ADA / ANSI <br />STEEL <br />MOUNT UNIT PER ADA & ANSI A117.1 REQUIREMENTS <br />KOHLER <br />1/2' <br />34' TO RIM <br />SYMMONS S20 FAUCET, CHROME STOPS/SUPPLIES <br />LVI <br />HANDICAPPED <br />KOHLER <br />2007, 2030 <br />1/2' <br />WHERE <br />2�/2' <br />2�/2' <br />COMPLY WITH <br />.25 GAL/MIN <br />WHITE <br />& P-TRAP WITH TAILPIECE, WATTS USG-B TEMPERING <br />WALL LAVATORY <br />OR EQUAL <br />OR 2861 <br />SHOWN <br />ADA / ANSI <br />DEVICE, J.R. SMITH 0700-D-E BACK TO BACK WALL <br />CARRIER. INSTALL PER ADA& ANSI-A117.1 REQUIREMENTS <br />WHI <br />SINGLE LAVATORY <br />POINT -OF -USE <br />ECOSMART <br />ECOSMART <br />1/2' <br />1/2' <br />WALL MOUNT <br />MOUNT ON WALL BELOW LAVATORY - VERIFY <br />WATER HEATER <br />POU 3.5 <br />ELECTRICAL VOLTAGE PRIOR TO ORDERING <br />www.jarch.com <br />info@jarch.com <br />® jonnattl Architecture <br />Incorporated 2022 <br />E OF Fto <br />Nr <br />2/"3/22 <br />ZEPHR <br />RETAIL <br />DEVELOPMENT <br />DOC MI <br />SUITE 6603 <br />US HTNY 301 <br />GALL BLVD <br />ZEPHYRHILL S <br />FLORIDA <br />33542 <br />PL �LM�B�IjNG <br />(Drawn <br />AIAJ <br />Check <br />MAJ <br />Date <br />JAN 18, 2022 <br />Scale <br />AS NOTED <br />Job No <br />ZEPHR RB <br />Sheet: <br />
The URL can be used to link to this page
Your browser does not support the video tag.