My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6794-6810 Ripple Pond Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6794-6810 Ripple Pond Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 3:45:12 AM
Creation date
2/19/2025 8:27:26 AM
Metadata
Fields
Template:
Building Plans
Street #
6794-6810
Location
Ripple Pond Lp
Contractor
Lennar Homes LLC
Building Plans - Permit #
5190-5194
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Attic Ventilation ATTIC VENTILATION CALCULATIONS <br />Attic Ventilation to be in compliance with the Florida Building Code 7th Edition ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED <br />(2020) Residential R806. <br />The Minimum net free ventilating area shall be 11150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% 1/150 Rule Ridge <br />1/300 Rule Off -Ridge <br />but no more than 50% of the required ventilation is provided in the upper portion of (No Upper Ventilators (Must Provide Upper Ventilators) Vent Amt Amt. <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet Req.) (Ft.) <br />(measured vertically) below the ridge or highest point of the space, with the - --- - -- - -- - -- Total <br />balance of the required ventilation provided by eave or cornice vents. Ventilation <br />"CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" ATTIC Provided <br />(Values to be verified with Manufacturer Specifications) SPACE SQ. FT. Total SQ. SQ. FT. SQ. IN. of by Upper <br />• OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT SQ. IN. of IN of vented IN. of . of SQ. IN. of of ventilation to SQ. Ventilators <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SO. FT. ventilation vented be provided (See Elev) <br />• STUCCO SOFFIT VENTS - 126 SO. IN. OF NET FREE AREA / SO. FT. required soffit ventilation soffit by upper Ventilation Ventilation <br />"If not enough vented soffit is provided due to fire protection, the contractor shall use the needed required needed ventilators <br />following approved vents: <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />"Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) 19 = Linear Ft. of Deck -Air Needed) -- - <br />Main 0.0 2.0 <br />Floor 1070 1027 147 514 37 257 - 276.0 <br />(Zone 1) 0.0 276.0 <br />Main 0.0 2.0 <br />Floor 992 952 136 476 34 238 276.0 <br />(Zone 2) 0.0 276.0 <br />-NOTE" <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />2 <br />REQUIRED BY FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL. <br />2 2 2 <br />FP-1 FP-1 FP-1 FP-1 2 <br />1 1 1 1 1 1 1 1 FP-1 <br />1 FP-1 FP-1 FP-1 FP-1 FP-1 FP-1 FP-1 FP-1 1 <br />FP-1 <br />FP-1 <br />I I <br />ZONE-2 ZONE-2 ZONE-2 ZONE-2 <br />1 a1 o wATTIC SPACE ATTIC SPACE ATTIC SPACE ATTIC SPACE I <br />� 1 <br />n rn <br />1 992 SQ. FT. FP 1 996 SQ. FT. 997 SQ. FT. 994 SQ. FT. I <br />I I <br />I i <br />I 3 0I <br />1 3 FP-1 3 3 1 <br />1 ti� FP-1 $ � a FP-1 � FP-1 _FQ 1 <br />O <br />1 rn "' n U <br />i,j is � •c <br />00, <br />I I <br />I I <br />I ZONE-1 FIRE RETARDANT PLYWOOD FIRE RETARDANT PLYWOOD FIRE RETARDANT PLYWOOD FIRE RETARDANT PLYWOOD ZONE-1 <br />1 <br />LOCATION. LOCATION. LOCATION, LOCATION, 1 <br />I ATTIC SPACE DO NOT BREACH00 DO NOT BREACH DO NOT BREACH DO NOT BREACH ATTIC SPACE 1 <br />1 1072 S . FT. 1070 SQ. FT. 1 <br />I Q I <br />4'-0" ROOF VENT 4'-0" ROOF VENT 4'-0" ROOF VENT 4'-0" ROOF VENT 4'-0" ROOF VENT 4'-0" ROOF VENT 4'-0" ROOF VENT 4'-0" ROOF VENT J 1 <br />I$ r O O LU <br />1 <br />6:12 SLOPE RIDGE 6:12 SLOPE <br />g RIDGE RIDGE RIDGE —� N <br />RIDGE RIDGE <br />sf Q <br />LU <br />I I <br />I I <br />Q I I I <br />I I 9 1 1 9 1 1 1Cr I I 1 <br />1 I i I I I I I I 1 <br />1 I I I I i I I I 1 <br />I <br />6� •12 SLOPE 6:12 SLOPE 6 E 6:12 6:12 SLOPE <br />1 1 1 1 1 1 E- 6:12 SLOPE � 1 6:12� SL�PE 6:12 SLOPE 1 <br />LU <br />I <br />� LU "-4 a <br />w n n (n <br />IJ cC tG cC <br />or <br />I w I w L <br />I I <br />I I I I I 1 <br />1-4 <br />ck; or <br />6,12 SLOPE 6:12 SLOPE <br />1 L� 1 FP-1 FP-1 ( �Q w LL, do 1 FP-1 FP-1 <br />1 w o <br />I 2 1 N N 1 2 1or <br />00I <br />1 6:12 SLOPE 1 I 1 16-12 SLOPE <br />I <br />FP-1 FP-1 FP-1 FP 1 FP-1 FP-1 <br />2 <br />\11FP-1 FP -1 FP-1 <br />4'-0" 4'_0" 4'-0" 4'-0" 4' 0" 4'_0" 4'-O" 4'-0" 4' 0" 4'-0" <br />UNIT 1500 UNIT 1397 UNIT 1397 UNIT 1397 UNIT 1397 ROOF PLAN <br />SCALE: 3/8"=1'-O" <br />0 <br />r' �z O <br />;Cr)N <br />5X <br />1L CL <br />O <br />u J Ri J <br />r t <br />J 5 (5 <br />__ -- C: C <br />n O O <br />` U = <br />¢ ^ LLJ <br />Q <br />> CL <br />J ' .PVC <br />N <br />�iJt W <br />J <br />rGi <br />r <br />- 1. ,- �; :; 1 (l'J' •Y^ti. <br />\�• <br />CNN <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />9) <br />E <br />O N <br />V N 00 <br />0 00 Co <br />Q1 fh V M V <br />C J LL W <br />w a <br />$ 90 <br />W_�O'Q m <br />w <br />IL M Z Q J <br />N J <br />O U U <br />= '0 <br />W El 13 <br />z <br />Q <br />/t� ''^^ N <br />(1L), V <br />V � <br />0 c <br />�fn ZD <br />U <br />' w <br />r-- E <br />I <br />V® <br />see <br />r_ <br />Cl) <br />4 <br />J <br />O <br />a� <br />� <br />E <br />U0 <br />Z <br />c�v It7 <br />0 4 <br />�z <br />fC <br />wz <br />wg <br />�� <br />ms <br />C <br />- <br />Y X <br />m0 <br />2 <br />z <br />di <br />N J <br />�b <br />Fp <br />a w <br />� <br />z 2 <br />�O <br />WC <br />a <br />O <br />LL <br />�w <br />W <br />W � <br />�5 <br />a <br />05 <br />_g <br />0 <br />�N <br />0 <br />.y <br />ICU <br />a) <br />g <br />a; <br />co 0 <br />_e) <br />a <br />OD <br />00 <br />vJ <br />O <br />T <br />m <br />Q <br />04 <br />c <br />M 04 <br />0 <br />LO <br />Cfl <br />00 <br />E <br />m <br />z <br />� T— <br />E <br />z <br />a. <br />E <br />1 U °� ¢ p <br />JOB <br />NO: 22-05620-05615 <br />SCALE : AS NOTED <br />SHEET NO. <br />10.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.