Laserfiche WebLink
• +'' �'" GENERAL CONCRETE LINTEL SCHEDULE <br />SYMMETRICAL <br />• • • •J11" <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY <br />8F8-16/1T 8F8-OB/1To IN TYPE DESIGNATION #5REBAR ATTOP O <br />MIN. (1) REQ'D = r , N <br />• • • ' " • F =FILLED WITH El::� _ `� � <br />GROUT / U =UNFILLED c LL X <br />8RF14-16/1T 8RF14-OB/iT R RECESSED ° CLEAR p L <br />,• �•• ' `• 48L © O QTY. OF #5 ° a CIL- <br />REBAR @BOTTOM I W r✓ Cy <br />;, • ; ;, r ; ;�'• ; OF LINTEL CAVITY a rJ 03 �J M <br />M.U. <br />ED <br />0 o , ° MS25 O D I vi i <br />z GROUT O (fr .- <br />•: -• LNOMINA t QUANTITY OF • 5 REBAR ATNEU <br />J S� <br />• • • • • , ,, • • • WIDTH #5 REBAR AT < BOTTOM OF <br />N <br />8F20-OB/1T 8F20-1 B/1 T 8F1 6-OB/1 T 8F16-1B/1T NOMINA TOP ° LINTEL CAVITY OTTOM I ^� )' (0 <br />® ® O ® HEIGHT REINFORCING <br />7-518"ACTUAL u <br />PROVIDED IN i f <br />8 NOMINAL WIDTH LINTEL- <br />• • (VARIES) H U} O O <br />MATERIALS <br />•'�' , • ` ;; ll_I <br />'•', • ' • �,'• ` • ', �•` 1. fc precast lintels = 3500 psi. > L L <br />• • 2. fc prestressed lintels = 6000 psi. <br />8RF6-OB/1 T •' .' ,• , . 3. grouted per ASTM C476 fg = 3000 psi w/ <br />• r ' , ' ILI :,L' 4. maximum 3/8" aggregate and 8" to 11" slump. <br />© • • . • 5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />' . , ' ;; : • ; 6. Rebar per ASTM A615 Grade 60. ' <br />,,�', •, , • Pre stow sing strand <br />per ASTM A416 grade r ±;;i+1;i ilrfj!'c-4 <br />7. <br />i • ,• '. • , • '. • 7/32 wire per ASTM A510. r� G <br />*,' • • :. <br />• �� • , • : 8. Mortar per ASTM C270 type M or S. <br />8F20-1 B-2T �'• <br />Y J <br />0. ; • • • • GENERAL INSTALLATION NOTES = n) - � � '•.o <br />• © 8RF22-1 B/1T 81F24-0113/11T 8F24-1113 T 1. Provide full mortar head and bed Joints. <br />• • • '. 2. Shore filled Ilntels as required. a <br />® O O 3, Installation of lintel must comply with the architectural and/or structural drawings. I .\'., :) 1� �FLU <br />,. 4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate Q� <br />• , • vertical cell reinforcing and grouting. � <br />All lintels meet or ex O 8 <br />' • � '. • ` , �'. • ` . . • , . • , 5. a exceed U360 vertical deflection, except lintels 1T-4" and rn <br />• ` ' • : • ;' longer with a nominal height of 8" meet or exceed U180. <br />• •' 6. Bottom field added rebar to be located at the bottom of the lintel cavity. v. • ••'a• ,,`.`` <br />• , ; •• '. , ; • ' , . , ; ', , r , • ` • ,7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />: ' ,-',`' g. Cast -in -place concrete may b8 provided in composite lintel In lieu Of concrete <br />' ' ' •' ' • masonry units. <br />' . • , • , • • ' ' L ' ' L ' L ' ` ' ' ' . • 9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />' ! • • ! • • % • • m 3 <br />11. 10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. o <br />'' ,•': • • , ': •, :`' : The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />• <br />' ' L , - • - • • '. ' • ' . • % • • 'L ' a coating of stucco applied in accordance with ASTM C-926 or other approved IF -1 <br />coating. LL _ <br />. '• ; ,; • . ' , ' • �', , •,; �'. , ' • • , ' . . , ,; • �'• 12. All lintel dimensions shown are "overall" lintel lengths. O Cr Cr 00 <br />13. Lintels loaded simultaneously with verical (gravity and uplift) and horizontal (lateral) r <br />' ' • `' loads shoud be checked for combine loading with the following equation: <br />r ' ,' • • `' . • ` ,'. • ,'. • , ,'. • , ' . ••, ,• • • • , Applied vertical load Applied horizontal load FP-1 To the best of the Engineer's knowledge, Information and belief, <br />`• ; ;' • ; '� ` • ; `,' '• • ' ' '' Safe vertical load +Safe horizontal load O ���� I the structural co plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />' • • . ' , • - . ' • • • • ' . • ' p9i Residential 7th Edition. Engineers signature and seal is only for <br />,• �� the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />11 <br />8F441B/1T8F40OB/1T 8RF40OB/1T 8F321B/1T 8F32OB/1T 8RF301B/1T 8F28OB/1T 8F281B/1T I H g E <br />CCND <br />Y O I p v 0 N 0 <br />ALTERNATE POWERS ire�JLL LL w <br />STEEL LINTEL LINTEL PLAN NOTES: �LLg a x <br />z'2� <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL q o W o co <br />m n g i <br />INFORMATION ONLY. <br />#S REBAR.(1)RED' 1-1/2" CLEAR AT TOP <br />MIN. (1) RE2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE z " <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. H W <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED O �, <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BELu <br />z <br />C.M.U. COORDINATED WITH THE ELEVATION DRAWINGS Z: <br />IL <br />13 <br />IL <br />i?st;x <br />'-Pm 4. THE CONTRACTOR IS RESPONSIBLE FORcl- <br />o o <br />W W J COORDINATING THE PROPER LINTEL HEIGHT. r - W <br />WD0 I O T z <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />a co ] N N <V�'o 5REBARATBOTTOM DEPTH REQUIRED FOR THE DESIGN LOADS. THE " I (DM w <br />aoo i A <br />S INDICATED DEPTH MAY BE INCREASED IF REQUIRED FOR <br />LL.0 <br />cn1 <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />GAUGE POWERS (a .- cn <br />STEEL BOXED LINTEL I U <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ' _ <br />r- E I <br />ONLY IF NOTED ON LINTEL PLAN POWER STEEL LINTEL IS AN ADEQUATE Of# ' <br />1. Refer to manufacturer's specifications for installation. o p i p 00 <br />SUBSTITUTION a@ ALL LOCATIONS UNLESS �10 <br />2. Contractor to provide proper protection of lintel to prevent rusting. <br />Refer to manufacturer's specifications. E G G E o <br />3. If lintel is scratched or damaged refer to Powers steel for repair. NOTED OTHERWISE AT OPENING LO CATION C/ <br />4. Lintel depth to match precast depth. One #5 Bar required at top o <br />see lintel plan/details for bottom steel required. 0 y <br />5. A bonding agent must be applied to the Steel Box lintels prior to rn E s z <br />applying the cementitiuos coating. See contractor specifications O O E _ <br />ma <br />to E) <br />¢ r o <br />O E Z <br />w <br />2" DIA. PIN #3 SHEAR REINFORCING=;I. J Z <br />$ wo <br />N <� <br />@ 16" O.C. gy zx <br />K.O. BLOCK COURSE H H H Z <br />O o <br />_ oo w/ 2 -#5 TOP ( MIN SOLID 3 O $ a= <br />O <br />4 GROUT) O MIN. MIN. MIN. I W cifIr <br />to <br />r (2) #5 REBAR @ BOTTOM A C> _ � o <br />OF LINTEL CAVITY <br />UNIT s �I <br />1500 UNIT 1397 UNIT 1397 N <br />4: <br />SYMMETRICAL <br />PRECAST LINTEL UNIT U-) <br />co <br />BY MANUF. <br />o j � <br />0 <br />(M <br />T <br />� T- r <br />S25 LINTEL W/ SHEAR REINF. M Q <br />Ob <br />Cr <br />N.T.S. REV 05.02.22 CAB � <br />oo <br />LINTEL PLANca <br />SCALE: 3/16"=1'-O" H o <br />C CV) <br />CD <br />�( <br />c� � <br />E c Z <br />m � T iii <br />Z E y <br />d U 0 Q p � <br />JOB NO: 22-05620-05615 <br />SCALE : AS NOTED <br />SHEET NO. <br />L 1 <br />