Laserfiche WebLink
i --I- 1 I i 1 I I 1 1 1 1 1 11 _ 1 I 1_ vi I, I_ q I I i <br />I ; I 1 1111,1 <br />N <br />(D <br />E- <br />O 0 <br />L • <br />r Q) <br />m <br />n <br />m U) <br />N j <br />N � <br />N Q <br />O N <br />N I <br />\ �p <br />O O <br />N <br />\ O <br />O / <br />6 <br />N <br />V) <br />W 0 <br />Q 3 <br />cn 0 <br />c- <br />0 <br />cf) I <br />Q „ <br />J 0 <br />N <br />a <br />N - <br />0 0 <br />6 0 <br />N + <br />O <br />C N <br />� N <br />m 0 <br />O <br />N <br />>- I <br />m Q- <br />�E <br />n <br />U) <br />N � <br />f co <br />N / <br />L <br />N pi <br />O c <br />N Q) <br />\ r7 <br />N to <br />07 <br />N <br />o / <br />w Ln <br />~ N <br />z/ <br />F <br />0 <br />COMPLIANCE NOTES <br />"PROPRIETARY SYSTEM" <br />1. THIS SYSTEM DESIGN IS BASED UPON COMPLIANCE WITH THE <br />NATIONAL, STATE AND LOCAL CODES. THE OCCUPANCY CLASS <br />IS MERCANTILE. THE FACILITY WILL BE PROTECTED THROUGHOUT <br />BY A FULLY SUPERVISED FIRE SPRINKLER SYSTEM PER NFPA 13 <br />AND NFPA 72. <br />2. ELECTRONIC SPRINKLER SUPERVISORY SERVICE IS PROVIDED <br />AND IS PROPRIETARY SYSTEM UNDER NFPA 72. <br />3. FLOW SWITCHES WILL BE PROVIDED ON ALL SPRINKLER <br />RISERS WITH ALARM ZONING COINCIDING WITH SPRINKLER <br />ZONING. <br />4. TAMPER SWITCHES WILL BE PROVIDED ON ALL VALVES, AND <br />WHERE APPLICABLE, ALL OTHER ELEMENTS ESSENTIAL TO THE <br />PROPER OPERATION OF THE SPRINKLER WILL ALSO BE <br />SUPERVISED. <br />5. REMOTE ANNUNCIATOR(S) WILL PROVIDE POINT <br />IDENTIFICATION ALL DEVICES/ZONES IN ALPHANUMERIC DISPLAY, <br />AND AT LEAST ONE WILL BE LOCATED AT A CONSTANTLY <br />ATTENDED LOCATION ON SITE. THE FACU CABINET HAS NO <br />ANNUNCIATOR OR USER INTERFACE CONTROLS, AND IS A <br />CABINET HOUSING (NON -ANALOG ADDRESSABLE) CIRCUITRY <br />ONLY. <br />6. AT LEAST ONE MANUAL STATION WILL BE INSTALLED AND <br />LOCATED WHERE REQUIRED BY THE AHJ, PER NFPA 72. UNLESS <br />OTHERWISE SPECIFIED BY THE AHJ, IT WILL BE LOCATED AT <br />THE CONTINUOUSLY ATTENDED LOCATION ON SITE, PER THE <br />DRAWINGS. <br />7. ONE SMOKE DETECTOR WILL BE INSTALLED ABOVE THE FACU <br />IN ACCORDANCE WITH NFPA 72 AND ANY REMOTE LOCATIONS <br />WHERE FIRE CONTROL EQUIPMENT IS INSTALLED. <br />8. AIR HANDLING UNITS IN EXCESS OF 2000 CFM WHICH <br />INCLUDE DUCT SMOKE DETECTORS SHALL SHUT DOWN THEIR <br />RESPECTIVE FANS AND CAUSE A "SUPERVISORY" SIGNAL ON <br />THE FACU PER NFPA 90A. SEE SCOPE OF MECHANICAL <br />CONTRACTOR SHOP DRAWINGS FOR DETAILS. <br />9. COOKING HOOD SUPPRESSION SYSTEM(S) (IF ANY) SHALL BE <br />CONNECTED TO THE SYSTEM TO CAUSE AN "ALARM" SIGNAL <br />UPON AGENT DISCHARGE, PER NFPA 17 AND NFPA 72. SEE <br />SUPPRESSION CONTRACTOR'S SHOP DRAWINGS FOR DETAILS. <br />(Ef <br />10. ALL NON -REQUIRED DEVICES INDICATED IN THE SUBMITTAL <br />(IF ANY), ARE VOLUNTARILY PROVIDED AND ARE DESIGNATED <br />AS "SUPPLEMENTARY" IN NATURE, AS DEFINED IN NFPA 72. <br />11. AUDIBLE AND VISUAL NOTIFICATION APPLIANCES ARE <br />PROVIDED AS INDICATED ON THE PLAN. <br />12. WALMART SECURITY TECHNOLOGY WILL INSTALL THE FIRE <br />ALARM WHERE LEGALLY ENTITLED BY LICENSING, PERMITTING, <br />CERTIFICATION OR EXEMPTION. LOCAL CONTRACTOR TO BE USED <br />ELSEWHERE. <br />13. OFF PREMISES, AUTOMATIC ALARM NOTIFICATION WALL BE <br />VIA TWO APPROVED MEANS OF COMMUNICATION TO WALMART'S <br />UL LISTED (UUFX) CENTER. SEE UL FILE #S3152-1 FOR <br />CERTIFICATE INFORMATION. <br />14. WIRING WILL BE INSTALLED PER (THE NEC) NFPA 70 AND <br />ALL OTHER APPLICABLE SECTIONS. ALL EQUIPMENT SHALL BE <br />PROPERLY LISTED PER NFPA 72. <br />15. THIS SYSTEM IS DESIGNATED AS A "PROPRIETARY <br />SUPERVISING STATION SYSTEM" IN ACCORDANCE WITH NFPA 72 <br />WITH 24 HOURS OF STAND-BY POWER THEN 5 MINUTES IN <br />"ALARM" PER NFPA 72. STORE MANAGEMENT PERSONNEL ARE <br />DESIGNATED FOR 1 HOUR RUNNER SERVICE. <br />16. THESE NOTES DO NOT SUPERSEDE REQUIREMENTS OF <br />OTHER TRADES, SPECIFICALLY INCLUDING MECHANICAL. <br />ELECTRONIC FIRE PROTECTION PLAN <br />DEMOLITION NOTES <br />1, ALARM INSTALLER TO MAINTAIN THE EXISTING FACU SYSTEM OPERATIONAL THROUGH THE REMODEL PROCESS AS REQUIRED BY <br />CODE. <br />2. CONTRACTOR MUST VISIT THE BUILDING TO DETERMINE THE FULL EXTENT OF THE EXISTING FIRE PROTECTION WORK AND EXISTING <br />CONDITIONS. BECOME TOTALLY FAMILIAR WITH THE DISCONNECTIONS, REMOVALS OF EXISTING FIRE ALARM EQUIPMENT, AND <br />CONDITIONS IN THE PROPOSAL FOR THIS PROJECT. NO EXTRA COMPENSATION WILL BE PAID FOR LACK OF SUCH DETERMINATION, <br />FAMILIARIZATION, AND/OR ALLOWANCE. <br />3. IN AREAS THAT DO NOT SHOW NOTIFICATION AND OR INITIATION DEVICES, EXISTING DEVICES SHALL REMAIN. <br />4. MAINTAIN A PRESENCE AT THE CONSTRUCTION MEETINGS AND KEEP UP WITH THE MOVES. IT IS RECOMMENDED THAT THE <br />CONTRACTOR REMOVE ANY AFFECTED DEVICES PRIOR TO DEMO EXCEPT FOR CRITICAL AREAS THAT WILL NEED TO BE COORDINATED <br />THE NIGHT OF THE MOVE. <br />5. QUANTITIES INCLUDES ASSOCIATED WIRING AND CONDUITS. NO ADDITIONAL COMPENSATION WILL BE GIVEN FOR WIRING AND <br />CONDUIT REMOVAL. <br />6. SPLICES ARE NOT ACCEPTABLE, RUN NEW WIRE TO NEW AND EXISTING DEVICES AFTER DEMO. <br />SCOPE OF WORK <br />1. AHU1; DISCONNECT EXISTING POPIT MODULE FROM EXISTING AHU1. CONNECT NEW POPIT MODULE TO NEW FACTORY INSTALLED DUCT DETECTORS. <br />INSTALL AND CONNECT REMOTE TEST SWITCH (RTS). <br />2. AHU2; DISCONNECT EXISTING POPIT MODULE FROM EXISTING AHU2. CONNECT NEW POPIT MODULE TO NEW FACTORY INSTALLED DUCT DETECTORS. <br />INSTALL AND CONNECT REMOTE TEST SWITCH (RTS). <br />3. AHU3; DISCONNECT EXISTING POPIT MODULE FROM EXISTING AHU3. CONNECT NEW POPIT MODULE TO NEW FACTORY INSTALLED DUCT DETECTORS. <br />INSTALL AND CONNECT REMOTE TEST SWITCH (RTS). <br />4. MAINTAIN COMPLETE FUNCTIONALITY OF FIRE ALARM SYSTEM THROUGHOUT DURATION OF REMODEL. <br />5. COMPLETE NFPA72 RECORD OF INSPECTION AND TESTING FORMS UPON COMPLETION, AND ALL APPLICABLE COMPLIANCE INSPECTIONS. <br />6. CONTRACTOR SHALL SUPPLY ALL BRIDLE RINGS AND ALL OTHER ASSOCIATED MATERIALS FOR WIRE MANAGEMENT. <br />7. REFERENCE DEMOLITION NOTES FOR SCOPE OF WORK. <br />ALARM SYMBOLS LEGEND <br />PLAN <br />SYMBOL <br />QTY <br />DEVICE DESCRIPTION <br />SYMBOL PLAN <br />QTY <br />DEVICE DESCRIPTION <br />FACU <br />1 <br />EXISTING FIRE ALARM CONTROL <br />NPS <br />2 <br />EXISTING NOTIFICATION POWER <br />SUPPLY ALTRONIX <br />PANEL BOSCH D9412GV4 <br />A = <br />L1002ULADA n UNIT NUMBER <br />FAC <br />2 <br />EXISTING CONTROL <br />NPS <br />1 <br />EXISTING NOTIFICATION POWER <br />SUPPLY ALTRONIX <br />ANNUNCIATOR BOSCH D1256RB <br />AL802ULADA n=UNIT NUMBER <br />FAA <br />1 <br />EXISTING SYSTEM ANNUNCIATOR <br />AND FIRE ALARM KEYPAD <br />O <br />EXISTING DETECTOR <br />SMOKE <br />SMOKE <br />BOSCH D1257RB <br />BOSCH D27 THE <br />6 <br />NEW AHU SMOKE DETECTOR <br />a <br />EXISTING MANUAL PULL STATION <br />BOSCH FMM-100 <br />(POINT OF CONNECTION ONLY) <br />T <br />}( <br />3 <br />NEW REMOTE TEST SWITCH <br />SYSTEM SENSOR RTS151 <br />AIM <br />3 <br />NEW/EXISTING POPIT <br />104 <br />MODULE BOSCH D9127U <br />PLAN ABBREVIATIONS <br />(E)-EXISTING TO REMAIN <br />(R)-RELOCATE <br />(N)-NEW <br />LOCATION: <br />WALMART STORE #0706 <br />7631 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33541 <br />Ln W <br />V N} <br />(3)c <br />�mm <br />J- J <br />N <br />CID <br />U <br />v z °° <br />Ln <br />m 1 <br />0 <br />o <br />o <br />Lu <br />� <br />u <br />ro <br />u) <br />(14 <br />Onoa <br />o <br />N Ix <br />�Ix <br />a <br />wZ"' <br />co <br />En <br />LZ �zz``'w owls <br />�o <br />o �(n z- <br />a2a*aZaowow <br />vi<W(o.) <br />aN> `cif tnm woOw <br />OM<0000�w W-jC.�NU- <br />a.�� <br />�nk'wox0-oo�-awL-w <br />Lj <br />O 3:( < Lf-"wWRQOF-z <br />om0000�z�zoa<6za <br />Q viVa-Qr-ai�W��Fa w*LLJ MQ <br />NwzF�dmONOOpNJ <br /><Zo �wWvOv)M WOFm Owxvn <br />ww <br />V) �odDzoawa(Aaw�aR <br />U) <br />H- <br />z <br />Q <br />H <br />J <br />V) <br />z <br />O <br />U <br />ISSUE BLOCK <br />CHECKED BY: <br />HOU <br />DRAWN BY: <br />BRY <br />POSSESSION DATE: <br />09/15/22 <br />DOCUMENT DATE: <br />10/26/22 <br />ELECTRONIC <br />FIRE <br />PROTECTION <br />PLAN <br />EFP1 <br />