Laserfiche WebLink
U) <br />D <br />o <br />N � <br />T <br />N -C <br />N Q- <br />O N <br />N <br />� O <br />� O <br />N <br />� O <br />O / <br />N <br />O � <br />W O <br />Q <br />Q 3 <br />O <br />U) <br />C I <br />J 0 <br />Q. <br />N <br />N - <br />�I <br />0 <br />c N <br />i N <br />m N <br />0 <br />N <br />� I <br />m0- <br />=� <br />n <br />rn a <br />N O <br />�W <br />N / <br />i <br />N pi <br />O Q <br />N N <br />CIA <br />r7 <br />N tC) <br />N <br />0 / <br />z / <br />a <br />EXISTING FIRE ALARM SYSTEM <br />INPUT/OUTPUT MATRIX <br />SYSTEM INPUTS <br />1 FIRE ALARM SYSTEM AC POWER FAILURE <br />2 FIRE ALARM SYSTEM LOW BATTERY <br />3 OPEN CIRCUIT <br />4 GROUND FAULT <br />5 NOTIFICATION APPLIANCE CIRCUIT SHORT <br />6 BUILDING MANUAL PULL STATIONS <br />7 AREA SMOKE DETECTORS <br />8 SPRINKLER WATERFLOW IN BUILDING <br />9 HVAC AIR DUCT SMOKE DETECTORS <br />10 HOOD FIRE SUPPRESSION SYSTEM ALARM <br />11 SPRINKLER TAMPER SWITCH <br />12 BACKFLOW VALVE TAMPER <br />13 FAILURE OF SIGNAL TRANSMISSION <br />14 DRY SYSTEM HIGH LOW PRESSURE <br />5 BDA SYSTEM TROUBLE <br />6 - <br />SYSTEM OUTPUTS <br />FACP ANNUNCIATION NOTIFICATION REQUIRED FIRE <br />SAFETY CONTROL <br />R <br />POD v�0�0.3 C - <br />\-S.Gj\�C�Pv <br />JP AZ � \��P \�� I,/ <br />PS�P�� `� \v��,�c• <br />AZN ��J <br />Q P P Q Q <br />SCOPE OF WORK C <br />Description <br />Device <br />Quantity <br />Sta ndby <br />Current <br />Total <br />Standby <br />Current <br />Alarm <br />Current <br />Total <br />Alarm <br />Current <br />ControlPanel <br />D9412GV4 <br />1 <br />0.2250 <br />0.2250 <br />0.3000 <br />0.3000 <br />Battery Lead Supervision Module <br />D113 <br />1 <br />0.0450 <br />0.0450 <br />0.0450 <br />0.0450 <br />SDI S litter <br />SDI-9114 <br />1 <br />0.0300 <br />0.0300 <br />0.0300 <br />0.0300 <br />Dual Class AB NAC Module <br />D192G <br />1 <br />0.0350 <br />0.0350 <br />0.1000 <br />0.1000 <br />Dual Phone Line DACT Module <br />D928 <br />1 <br />0.0200 <br />0.0200 <br />0.1000 <br />0.1000 <br />Annunciator / Keypad A <br />D1256 <br />1 <br />0.1040 <br />0.1040 <br />0.2060 <br />0.2060 <br />POPEX Module <br />D8125 <br />1 <br />0.0600 <br />0.0600 <br />0.0600 <br />0.0600 <br />POPITS <br />D9127 <br />107 <br />0.0005 <br />0.0535 <br />0.0008 <br />0.0856 <br />Auxilary Relay Module <br />D130 <br />2 <br />0.0600 <br />0.1200 <br />Dual from-C Relay (on Alann) <br />D8130 <br />1 <br />0.0070 <br />0.0070 <br />0.0600 <br />0.0600 <br />12v-4w Smoke Detector <br />D273THE <br />2 <br />0.0150 <br />0.0300 <br />0.0360 <br />0.0720 <br />TOTALS <br />TOTAL <br />STANDBY <br />0.610 <br />TOTAL <br />ALARM <br />1.179 <br />COMPUTATIONS <br />TOTAL AMPS USED INSTANDBY= 0.610 X 24 HOURS = 14L628 AH <br />TOTAL AMPS USED IN ALARM= 1.179 X 5 MIN = 0.098 AH <br />+20%CONTINGENCY 2.945 AH <br />TOTAL STANDBY BATTERY REQUIREMEVTS= 17.671 AH <br />TOTAL BACKUP BATTERYPROVIDTD= 36.000 AH <br />TOTAL BACKUP BATTERYREQUIREl)- 17.671 AH <br />TOTAL BACKUP BATTERY RESERVED= 18.329 AH <br />Existing (2)18 Ah batteries to provide 36 Ah at 12 volts <br />WIRE LEGEND <br />A <br />- - - - - --••-••-••-• - - - ---•-••- <br />FIRE ALARM SYSTEM 3pr #18 AWG FPL TWISTED <br />B <br />----------------------------- <br />NOTIFICATION CIRCUIT 1pr #12 AWG FPL ZIP <br />C <br />----------------------------- <br />EXISTING NOTIFICATION CIRCUIT 1pr #12 AWG <br />FPL ZIP <br />D <br />PLENUM RATED CABLE FPLP SHALL BE UTILIZED IN PLENUM RATED CEILING AREAS ONLY <br />WP = WEATHERPROOF CABLE SHALL BE PROVIDED AS REQUIRED <br />(+) POSITIVE CIRCUIT POLARITY (-) NEGATIVE CIRCUIT POLARITY <br />PLAN ABBREVIATIONS <br />(E)-EXISTING TO REMAIN <br />(R)-RELOCATE <br />(N)-NEW <br />ALARM SYMBOLS LEGEND <br />PLAN <br />SYMBOL <br />QTY <br />DEVICE DESCRIPTION <br />SYMBOL PLAN <br />QTY <br />DEVICE DESCRIPTION <br />FACU <br />1 <br />EXISTING FIRE ALARM CONTROL <br />NPS <br />2 <br />EXISTING NOTIFICATION POWER SUPPLY ALTRONIX <br />PANEL BOSCH D9412GV4 <br />AL1002ULADA n=UNIT NUMBER <br />FAC <br />2 <br />EXISTING CONTROL <br />NPS <br />1 <br />EXISTING NOTIFICATION POWER <br />SUPPLY ALTRONIX <br />ANNUNCIATOR BOSCH D1256RB <br />AL802ULADA n=UNIT NUMBER <br />FAA <br />1 <br />EXISTING SYSTEM ANNUNCIATOR <br />AND FIRE ALARM KEYPAD <br />0- <br />EXISTING SMOKE DETECTOR <br />BOSCH D1257RB <br />BOSCH D273THE <br />ns <br />6 <br />NEW AHU SMOKE DETECTOR <br />a <br />EXISTING MANUAL PULL STATION <br />BOSCH FMM-100 <br />(POINT OF CONNECTION ONLY) <br />RTS <br />}( <br />3 <br />NEW REMOTE TEST SWITCH <br />SYSTEM SENSOR RTS151 <br />AIM <br />%141MODULE <br />NEW/EXISTING POPIT <br />BOSCH D9127U <br />SCOPE OF WORK <br />CEN TR AL (E) (E)------N)-----------------N----------------- �N--------- <br />TO EXISTING <br />STATION_.._.._.._.._.._.. I M _.._.._.._.._.._.. I M _.._.. �.._.._.._.._.._.._.. I M_.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.. I M_.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.. I M _.._.._.._.._.._.._.._.._.. �._.._.. BURGLAR AND <br />I I I : FIRE ALARM <br />(WARM AR T I (N)_ _ (N) (N)- - (N) (N)- _ (N) i INITIATING DEVICES <br />FA C U (E) F _.._.._........ S S _.._.._.._.._.._.._.. S _.._.._.._.._.._.._. S <br />1 800 530 9924#1) , <br />EXISTING BOSCH CUSTOMER (N) (N) (N) <br />I SERVICE � <br />:*IRTS D9412GV4 � RTS I I� 1 IRTS � <br />AHU1 AHU2 AHU3 <br />12 VD C S (E) L------------------------------------------------------. J <br />-(� <br />P <br />ABOVE <br />FAC U <br />I <br />I <br />I <br />I <br />i <br />(� D A TA COURTESY DESK LIQUOR SALES VESTIBULE-GR <br />:1 2VDC------ <br />_.._.._.._.._.._.. <br />TOEXISTING L.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.. F A C ------ FA C _.._.._.._.._.._.. FA A <br />NOTIFICATION POWER D1256RB (E) E) E <br />SUPPLIES #1-#3 D1256RB ( D1257RB ( ) <br />ELECTRONIC FIRE <br />1 PROTECTION RISER DIAGRAM <br />NOT TO SCALE <br />LOCATION: <br />WALMART STORE #0706 <br />7631 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33541 <br />V 1 LLB <br />7 N } <br />�a <br />0 com <br />ID N <br />co <br />co <br />V <br />�z <br />m <br />oZ <br />c� <br />S <br />o <br />� <br />� <br />G <br />U <br />U') <br />O <br />n <br />0 t <br />6 <br />m <br />v o a <br />L• O <br />N N C6 <br />z <br />(� a <br />��w <br />0 <br />w v <br />O_ ~ ZWO Oza <br />Uj w <n <br />z- <br />of mmw*z9aeWUM01wo <br />0: aN>-c10 om%nwo3wm <br />� aQSct onUl wwwJ5Na} <br />OZ 3NQ0Ow86vLoo�o <br />Q Zc`-iaOma�OiwCk:L < 3 <br />J aWaWa�zFwwV)L))Qzw< <br />�(IIZON� www OWOw <br />F-- �ZONo ��o(ro :)F- <br />�Oe'DzonW<vWwwa:<� <br />N <br />z <br />Q <br />J <br />to <br />z <br />O <br />U <br />ISSUE BLOCK III <br />CHECKED BY: <br />HOU <br />DRAWN BY: <br />BRY <br />POSSESSION DATE: <br />09/15/22 <br />DOCUMENT DATE: <br />10/26/22 <br />ELECTRONIC <br />FIRE <br />PROTECTION <br />RISER AND <br />CALCULATIONS <br />