CONTRACTOR NOTES:
<br />39. ALL WOOD IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED MOISTURE RESISTANT.
<br />1. ALL WORK SHALL BE DONE IN A SAFE WORKMANLIKE MANNER AND IN STRICT ACCORDANCE WITH THE LOCAL AND/ OR
<br />STATE (IF APPLICABLE) BUILDING CODES. NATIONAL ELECTRIC CODE (NEC), ADA-ADAAGS (ADOPTED HANDICAPP 40. REPAIR ROOF AT ALL ROOF PENETRATIONS AS REQUIRED TO MAINTAIN A WATERTIGHT I PRE- PENETRATED ROOF
<br />ACCESSIBILTY REQUIRMENTS), OSHA AND ALL APPLICABLE CODES, REGULATIONS, ORDINANCES AND AUTHORITITES SYSTEM.
<br />HAVEING JURISDICTION.
<br />41. RE -KEY ALL EXISTING LOCKSETS.
<br />2. TO THE EXTENT REQUIRED BY LAW ALL WORK SHALL BE PERFORMED BY INDIVIDUALS DULY LICENSED AND AUTHORIZED
<br />BY LAW TO PERFORM SAID WORK. 42. PROVIDE SIGN ON EXTEROR DOORS STATING "DOOR TO REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED",1" HIGH
<br />LETTERS.
<br />3. CONTRACTOR MAY AT ITS DISCRETION ENGAGE SUBCONTRACTORS TO PERFORM WORK HEREUNDER, PROVIDED
<br />CONTRACTOR SHALL FULLY PAY SAID SUBCONTRACTOR AND IN ALL INSTANCES REMAIN RESPONSIBLE FOR THE PROPER 43, PROVIDE PANIC HARDWARE ON EXIT DOORS. FIELD VERIFY IF EXISTING.
<br />COMPLETION OF THIS CONTRACT.
<br />44.
<br />ALL DOOR HARDWARE TO MEET ADA GUIDELINES.
<br />4. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS
<br />IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELVES WITH THIS KNOWLEDGE DOES NOT RELIEVE THEM OF
<br />45.
<br />PROVIDE SIGN STATING MAXIMUM OCCUPANT LOAD WHERE REQUIRED BY AUTHORITY HAVING JURISDICTION.
<br />ANY RESPONSIBLITY FOR PERFORMING THEIR WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED
<br />BECASUE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE.
<br />46.
<br />PROVIDE FIRESTOPPING MATERIAL AT ALL PENETRATIONS OF ANY FIRE WALL.
<br />5. THE CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE EXISTING BUILDING SECURITY AT ALL TIMES. THIS INCLUDES
<br />47.
<br />IF MODIFICATION TO FIRE ALARM SYSTEM (WHEN PRESENT) IS REQUIRED, GENERAL CONTRACTOR SHALL HIRE A
<br />KEEPING THE BUILDING SECURE FROM PERSONS, ENVIRONMENTAL ELEMENTS OR HAZARDS. THE CONTRACTOR SHALL
<br />LICENSED FIRE ALARM CONTRACTOR. FIRE ALARM CONTRACTOR TO SUBMIT SIGNED AND SEALED FIRE ALARM DRAWINGS
<br />BE RESPONSIBLE TO MAINTAIN THE INTEGRITY OF ALL EXISTING SECURITY SYSTEMS.
<br />TO THE ARCHITECT FOR APPROVAL PRIOR TO ANY ALTERATION OF THE FIRE ALARM SYSTEM. WORK TO BE DONE UNDER
<br />SEPARATE PERMIT.
<br />6. CONTRACTOR SHALL FURNISH OWNER APPROPRIATE RELEASES OR WAIVERS OF LIEN FOR ALL WORK PERFORMED OR
<br />MATERIALS PROVIDED AT THE TIME THE NEXT PERIODIC PAYMENT SHALL BE DUE.
<br />ACCESSABILITY NOTES:
<br />7. ALL CHANGE ORDERS SHALL BE IN WRITING AND SIGNED BY BOTH OWNER AND CONTRACTOR.
<br />1.
<br />H.C. ACCESS TO THESE FACILITIES SHALL BE PROVIDED AT PRIMARY ENTRANCE
<br />8. CONTRACTOR WARRANTS IT IS ADEQUATELY INSURED FOR INJURY TO ITS EMPLOYEES AND OTHERS INCURRING LOSS OR
<br />2.
<br />THE SLOPE OF PUBLIC WALKS SHALL NOT EXCEED MAX CROSS SLOPE 2% WALKING SURFACE SLOPING GREATER THEN
<br />INJURY AS A RESULT OF THE ACTS OF CONTRACTOR OR ITS EMPLOYEES AND SUBCONTRACTORS.
<br />2% SHALL BE SLIP RESISTANT
<br />9. CONTRACTOR SHALL AT ITS OWN EXPENSE OBTAIN ALL PERMITS NECESSARY FOR THE WORK TO BE PERFORMED,
<br />3.
<br />EVERY REQUIRED EXIT DOORWAY SHALL BE SIZED FOR A DOOR NOT LESS THEN 3'-0" WIDE BY NOT LESS THEN 6-8" HIGH
<br />CAPABLE OF OPENING 900 DEGREES AND MOUNTED TO THAT THE CLEAR WIDTH OF EXIT WAY IS 32" MIN.
<br />10. CONTRACTOR AGREES TO REMOVE ALL DEBRIS AND LEAVE THE PREMISES IN BROOM CLEAN CONDITION.
<br />4.
<br />THRESHOLD TO BE MAX 114" ABOVE ADJACENT FINISH FLOOR
<br />11. IN THE EVENT OWNER SHALL FAIL TO PAY ANY PERIODIC OR INSTALLMENT PAYMENT DUE HEREUNDER, CONTRACTOR
<br />MAY CEASE WORK WITHOUT BREACH PENDING PAYMENT OR RESOLUTION OF ANY DISPUTE.
<br />5.
<br />MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS.
<br />12. ALL DISPUTES HEREUNDER SHALL BE RESOLVED BY BINDING ARBITRATION IN ACCORDANCE WITH THE RULES OF THE
<br />6.
<br />THE BOTTOM 10" OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE.
<br />AMERICAN ARBITRATION ASSOCIATION.
<br />7.
<br />PROVIDE LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO
<br />13. CONTRACTOR SHALL NOT BE LIABLE FOR ANY DELAY DUE TO CIRCUMSTANCES BEYOND ITS CONTROL INCLUDING
<br />PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE (30" TO 44" AFF.)
<br />STRIKES, CASUALTY OR GENERAL UNAVAILABILITY OF MATERIALS.
<br />8.
<br />ALL DOORWAYS LEADING TO SANITARY FACILITIES SHALL HAVE 36" CLEAR UNOBSTRUCTED OPENINGS.
<br />14. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE OSHA RULES AND REGULATIONS.
<br />9.
<br />LOCATE W.C. IN A 60" X 48" MIN. AREA (ADA),18" FROM WALL TO CENTER LINE OF W.C.
<br />15. ALL CONSTRUCTION CONDITIONS TO BE VERIFIED IN THE FIELD, ANY DISCREPANCIES, OMISSIONS AND ERRORS
<br />DISCOVERED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION AT ONCE. THIS INCLUDES
<br />10.
<br />PROVIDE 1112" 0 GRAB BARS AT 33" AFF. AT REAR AND SIDE OF W.C. GRAB BAR AT SIDE TO BE 42" LONG AND EXTEND 54"
<br />EXISTING AND NEW CONDITIONS AND DIMENSIONS. THE CONTRACTOR IS NOT TO PROCEED WITH OUT CONTACTING THE
<br />FROM BACK WALL OF TOILET. GRAB BAR TO BE 36" LONG AT BACK WITH 1112" CLEAR FROM WALL. BAR FASTENERS AND
<br />ARCHITECT.
<br />MOUNTING SUPPORTS TO WITHSTAND A MIN. 25 LBS. PER FT. IN BENDING, SHEAR STRESS AND SHEAR FORCE.
<br />16, THE CONTRACT DOCUMENTS ARE A GRAPHIC REPRESENTATION OF THE CONDITIONS AND THE WORK TO BE DONE. THESE
<br />11.
<br />WATER CLOSETS SHALL HAVE A SEAT HEIGHT OF 17" TO 19" AFF., FLUSH VALVE TO HAVE MAX 5 LBS OPERATING FORCE.
<br />DOCUMENTS SHOULD NOT BE SCALED. THE WRITTEN DIMENSIONS SHALL TAKE PRECEDENT OVER ANY AND ALL
<br />SCALED DIMENSIONS. THE MANUFACTURERS SPECIFICATIONS SUPERSEDE THE CONTRACT DOCUMENTS AS APPLICABLE.
<br />12,
<br />PROVIDE 30" X 48" CLEAR SPACE IN FRONT OF LAVATORY AND 29" CLEAR FROM FLOOR TO BOTTOM OF APRON KNEE
<br />SPACE.
<br />17. ANY DEVIATION FROM THE CONTRACT DOCUMENTS MUST BE APPROVED BY THE ARCHITECT PRIOR TO CONSTRUCTION.
<br />ANY CHANGES THAT ARE NOT APPROVED SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR
<br />13.
<br />LOCATE TOILET PAPER DISPENSERS ON THE WALL WITHIN 12" OF THE FRONT EDGE OF THE TOILET SEAT AND 19" AFF.
<br />18. ALL MATERIALS, SYSTEMS, AND COMPONENTS SHALL BE AS SPECIFIED AND INSTALLED IN ACCORDANCE WITH THE
<br />MANUFACTURER'S INSTRUCTIONS AND SPECIFICATIONS. THE CONTRACTOR COORDINATES THE WORK OF ALL TRADES, IN NOTICE REQUIRED FOR STRUCTURES WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION
<br />ORDER TO ASSURE PROPER COORDINATION.
<br />1. PURPOSE: THE PURPOSE OF THIS RULE IS TO REQUIRE THE PLACEMENT OF AN IDENTIFYING SYMBOL ON STRUCTURES
<br />19. THE CONTRACTOR IS RESPONSIBLE FOR THE STORAGE AND SECURITY OF ALL BUILDING MATERIALS. THEY SHALL KEEP CONSTRUCTED WITH A LIGHT -FRAME TRUSS COMPONENT IN A MANNER SUFFICIENT TO WARN PERSONS CONDUCTING
<br />THE PREMISES AND WORK AREA IN A REASONABLY NEAT AND ORDERLY CONDITION. THE CLEANING OF THE AREAS ON A FIRE CONTROL AND OTHER EMERGENCY OPERATIONS OF THE EXISTENCE OF LIGHT -FRAME TRUSS -TYPE CONSTRUCTION
<br />TIMELY BASIS IS NOT TO INTERFERE WITH ANY CONSTRUCTION CURRENTLY UNDER WAY. IN THE STRUCTURE.
<br />20, THE CONTRACTOR SHALL KEEP WORK AREA CLEAN AND FREE OF DEBRIS AND IS TO REMOVE ALL TRASH AND DEBRIS
<br />FROM THE CONSTRUCTION AREA DAILY. NO FLAMMABLE MATERIALS OR LIQUIDS MAY BE STORED IN THE EXISTING
<br />BUILDING OR ANY NEW ADDITION.
<br />21. REMOVE ANY EXISTING ITEMS, SERVICES, FINISHES OR SURFACES AS REQUIRED FOR THE INSTALLATION OF NEW
<br />CONSTRUCTION. PROVIDE FURRING FOR CONDUITS AND PIPING, SHOWN OR NOT, AND FINISH OUT FURRING TO MATCH
<br />ADJACENT EXISTING FINISHES.
<br />2. DEFINITIONS.
<br />(a) "LIGHT -FRAME TRUSS -TYPE CONSTRUCTION" MEANS A TYPE OF CONSTRUCTION WHOSE PRIMARY STRUCTURAL ELEMENTS
<br />ARE FORMED BY A SYSTEM OF REPETITIVE WOOD OR LIGHT GAUGE STEEL FRAMING MEMBERS.
<br />(b) "APPROVED SYMBOL" MEANS A MALTESE CROSS MEASURING 8 INCHES HORIZONTALLY AND 8 INCHES VERTICALLY, OF A
<br />BRIGHT RED REFLECTIVE COLOR, DESIGNED IN ACCORDANCE WITH FIGURE 1.
<br />3. ANY COMMERCIAL, INDUSTRIAL, OR MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE, WHICH USES
<br />HORIZONTAL OR VERTICAL LIGHT -FRAME TRUSS -TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED WITH AN
<br />22.
<br />REPAIR, RE-ROUTE, AND EXTEND ALL SERVICES, PIPING, CONDUIT OF EXISTING ITEMS AND EQUIPMENT AS REQUIRED
<br />APPROVED SYMBOL. TOWNHOUSES ARE NOT MULTIUNIT RESIDENTIAL STRUCTURES AND THEREFORE NOT SUBJECT TO
<br />DURING THE CONSTRUCTION PROCESS FOR THE COMPLETE INSTALLATION AND OPERATIONS OF NEW EQUIPMENT, THIS
<br />THIS RULE. EACH APPROVED SYMBOL SHALL INCLUDE WITHIN THE CENTER CIRCLE ONE OF THE FOLLOWING
<br />INCLUDES ALL ITEMS SHOWN OR NOT SHOWN ON THE DRAWINGS. RESET EXISTING EQUIPMENT OR RELATED ITEMS AS
<br />DESIGNATIONS:
<br />REQUIRED FOR PROPER OPERATION.
<br />(a)
<br />STRUCTURES WITH LIGHT -FRAME TRUSS ROOFS SHALL BE MARKED WITH THE LETTER "R".
<br />(b)
<br />STRUCTURES WITH LIGHT -FRAME TRUSS FLOOR SYSTEMS SHALL BE MARKED WITH THE LETTER "F".
<br />23.
<br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE TIMELY ORDERING OF MATERIALS TO PROHIBIT DELAYS OF THE
<br />(c)
<br />STRUCTURES WITH LIGHT -FRAME TRUSS FLOOR AND ROOF SYSTEMS SHALL BE MARKED WITH THE LETTERS "RF."
<br />CONSTRUCTION SCHEDULE OF THIS PROJECT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE
<br />DELIVERY OF MATERIALS IN A TIMELY MANNER.
<br />4.
<br />THE APPROVED SYMBOL SHALL BE PLACED WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY DOOR AND:
<br />(a)
<br />BE PERMANENTLY ATTACHED TO THE FACE OF THE STRUCTURE ON A CONTRASTING BACKGROUND, OR
<br />24.
<br />THE GENERAL CONTRACTOR SHALL RESPOND TO ALL REQUIREMENTS OF THE ENGINEER/ARCHITECT FOR
<br />(b)
<br />BE MOUNTED ON A CONTRASTING BASE MATERIAL WHICH IS THEN PERMANENTLY ATTACHED TO THE FACE OF THE
<br />VERIFICATIONS, RESPONSES AND SUBMISSIONS.
<br />STRUCTURE.
<br />25.
<br />DURING ENTIRE CONSTRUCTION PERIOD, PROVIDE ONE U.L. LISTED 2A:20BC DRY CHEMICAL FIRE EXTINGUISHER, OR ONE
<br />5.
<br />THE DISTANCE ABOVE THE GRADE, WALKING SURFACE OR THE FINISHED FLOOR TO THE BOTTOM OF THE SYMBOL SHALL
<br />STANDARD U.L. LISTED 2-112 GALLON WATER (E-10) AND ONE U.L. LISTED 1013C CARBON DIOXIDE FIRE EXTINGUISHER
<br />BE NOT LESS THAN 4 FEET (48 IN.).
<br />MOUNTED TOGETHER IN EACH 3000 SQ. FT. OF WORK AREA OR FRACTION THEREOF (MINIMUM OF TWO AVAILABLE IN ALL
<br />CONSTRUCTION AREAS AT ALL TIMES.)
<br />6.
<br />THE DISTANCE ABOVE THE GRADE, WALKING SURFACE OR THE FINISHED FLOOR TO THE TOP OF THE SYMBOL SHALL BE
<br />NOT MORE THAN 6 FEET (72 IN.).
<br />26.
<br />IF MODIFICATION TO SPRINKLER SYSTEM (WHEN SPRINKLED) IS REQUIRED, GENERAL CONTRACTOR SHALL HIRE A
<br />LICENSED SPRINKLER CONTRACTOR. SPRINKLER CONTRACTOR TO SUBMIT SIGNED AND SEALED SPRINKLER DRAWINGS
<br />7.
<br />IN SINGLE TENANT STRUCTURES WITH MULTIPLE MAIN ENTRY DOORS, SUCH AS BIG BOX COMMERCIAL STORES,
<br />TO THE ARCHITECT FOR APPROVAL PRIOR TO ANY ALTERATION OF THE AUTOMATIC SPRINKLER SYSTEM. WORK TO BE
<br />DEPARTMENT STORES AND GROCERY STORES, THE AUTHORITY HAVING JURISDICTION IS AUTHORIZED TO REQUIRE THAT
<br />DONE UNDER SEPARATE PERMIT.
<br />OTHER MAIN ENTRY DOORS OF THE STRUCTURE BE MARKED WITH AN APPROVED SYMBOL TO CARRY OUT THE PURPOSE
<br />27. CONTRACTOR IS RESPONSIBLE FOR PROTECTING ADJACENT PREMISES FROM MOISTURE, CONSTRUCTION NOISE, DUST
<br />AND DEBRIS.
<br />28. ANY DAMAGE CAUSED BY THE CONTRACTOR TO EXISTING FACILITY TO REMAIN SHALL BE REPAIRED TO BEFORE DAMAGE
<br />CONDITIONS AT THE CONTRACTOR'S SOLE EXPENSE.
<br />29. COORDINATE ALL WORK TO BE DONE WITH ALL THE CONTRACTORS INVOLVED PRIOR TO INSTALLATION.
<br />30. FIELD VERIFY LOCATIONS OF PIPING, EQUIPMENT, STRUCTURAL COMPONENTS, ETC. PRIOR TO COMMENCING ANY WORK.
<br />31. PROVIDE ADA COMPLIANT PRO WRAP DRAIN AND STOP INSULATION SYSTEM OR DRAINSHEILD ON ALL LAVATORIES.
<br />32. ALL SPECIFIED ELECTRICAL NOTES ARE REQUIRED, ALL EQUIPMENT AND OUTLETS ARE TO BE PLACED BY GENERAL
<br />CONTRACTOR.
<br />IN SUBSECTION (1) ABOVE.
<br />8. IN MULTIPLE TENANT STRUCTURES AND COVERED MALL STRUCTURES WITH MULTIPLE MAIN ENTRY DOORS, THE
<br />AUTHORITY HAVING JURISDICTION IS AUTHORIZED TO REQUIRE THAT OTHER MAIN ENTRY DOORS OF THE STRUCTURE BE
<br />MARKED WITH AN APPROVED SYMBOL TO CARRY OUT THE PURPOSE IN SUBSECTION (1) ABOVE.
<br />9. IN MULTIPLE TENANT STRUCTURES AND COVERED MALLS WITH MULTIPLE MAIN ENTRY DOORS, THE AUTHORITY HAVING
<br />JURISDICTION IS AUTHORIZED TO REQUIRE THAT OTHER MAIN ENTRY DOORS BE MARKED WITH AN APPROVED SYMBOL
<br />TO CARRY OUT THE PURPOSE IN SUBSECTION (1) ABOVE. IN SUCH STRUCTURES, APPROVED SYMBOLS SHALL BE MARKED
<br />ON ONE SIDE OF THE STRUCTURE ONLY AND SPACED NOT CLOSER THAN 100 FEET OR AT EACH END OF THE STRUCTURE
<br />WHEN SUCH STRUCTURE IS LESS THAN 100 FEET IN LENGTH.
<br />10. THE OWNER OF EACH NEW STRUCTURE REQUIRED TO COMPLY WITH THIS SECTION SHALL MARK THE STRUCTURE WITH
<br />THE APPROVED SYMBOL PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY.
<br />33. EMERGENCY LIGHTS INSTALLED BY GENERAL CONTRACTOR PER LOCAL CODE.18. EXIT LIGHTS INSTALLED BY GENERAL 11. THE OWNER OF EACH EXISTING STRUCTURE REQUIRED TO COMPLY WITH THIS SECTION SHALL MARK THE STRUCTURE
<br />CONTRACTOR PER LOCAL CODE. WITH THE APPROVED SYMBOL WITHIN 90 DAYS OF THE EFFECTIVE DATE OF THIS RULE.
<br />34. FIRE EXTINGUISHERS, SMOKE AND FIRE DETECTION SYSTEMS INSTALLED BY GENERAL CONTRACTOR PER LOCAL CODE. 12. WHERE THE OWNER OF THE STRUCTURE AND THE AUTHORITY HAVING JURISDICTION DISAGREE AS TO THE USE OF
<br />LIGHT -FRAME TRUSS -TYPE CONSTRUCTION WITHIN THE STRUCTURE, THE OWNER SHALL BE GRANTED NOT MORE THAN
<br />35. ALL DIMENSIONS TO BE VERIFIED BY GENERAL CONTRACTOR ON SITE. 45 DAYS TO PROVIDE WRITTEN VERIFICATION FROM A LICENSED ENGINEER OR LICENSED ARCHITECT; OTHERWISE, THE
<br />OWNER SHALL COMPLY WITH THE RULE.
<br />36. GENERAL CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO ALL OWNER FURNISHED ITEMS.
<br />FIGURE 1:
<br />37. GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE DELIVERY, RECEIVE, UNLOAD, STORE, PROTECT AND HANDLE
<br />ALL FURNITURE, FIXTURES AND EQUIPMENT FROM THE DELIVERY TRUCK INTO THE STORE AND THROUGH THE COMPLETE
<br />INSTALLATION PROCESS, ANY ITEMS DAMAGED AFTER RECEIVING SHALL BE REPLACED AS DETERMINED BY THE OWNER,
<br />AT THE CONTRACTOR'S SOLE EXPENSE.
<br />38. MECHANICAL, PLUMBING, AND ELECTRICAL SHALL BE DONE ON A DESIGN BUILD BASIS BETWEEN THE OWNER AND THE
<br />CONTRACTOR.
<br />LIGHT -FRAME "ROOF" ONLY
<br />LIGHT -FRAME "FLOOR" ONLY
<br />LIGHT -FRAME "FLOOR & ROOF"
<br />Robert E. Gregg FL #9927
<br />KY #3396
<br />CT #5153
<br />SC #4334
<br />NJ #15414
<br />MS #2335
<br />VA #6737
<br />OP, 1#5596
<br />TN #4334
<br />Copy of this plan is not valid unless
<br />signed, sealed and dated by the
<br />architect of record
<br />Copywrite:
<br />This drawing is the property of
<br />R.E. Gregg Architects and under no
<br />circumstances may this drawing be
<br />reproduced, published, altered or used
<br />in any way without written authorization
<br />from R.E. Gregg Architects.
<br />Contractor shall check and
<br />verify all dimensions and
<br />coordinate all field conditions.
<br />All discrepancies and conflicts
<br />shall be reported to the architect
<br />in writing prior to proceeding or
<br />continuing with construction.
<br />Unreported discrepances and
<br />conflicts shall remain the
<br />responsibility of the contractor.
<br />pJ
<br />w0
<br />LL
<br />ED
<br />Cl.)
<br />C15
<br />�
<br />�
<br />J
<br />z
<br />Q
<br />=
<br />=
<br />N
<br />r-
<br />N
<br />00
<br />I,, -
<br />DRAWN BY: KG
<br />CHECKED BY: REG
<br />ISSUE DATE:
<br />ISIONS:
<br />GENERAL NOTES
<br />1-12-2022
<br />G003
<br />
|