E <br />J <br />Ifl <br />ROOF TO P U NIT SCH EDU LE EXISTING) <br />Tag <br />MANUFACTURER <br />MODEL <br />SERVICE AREA <br />NOMINAL <br />TONNAGE <br />SUPPLY FAN (HP) <br />_.:. _... <br />HP ESP' <br />SUPPLY <br />AIRFLOW <br />OUTDOOR <br />AIR <br />COOLING CAPACITY <br />ELECTRICAL <br />VPN <br />NOTES <br />Total <br />Sensible <br />CFM <br />CFM <br />MBH <br />MBH <br />RTU (EXISTINGI <br />TRANS <br />TSC072 <br />SALES <br />6.0 <br />__ <br />__ <br />2120 <br />310 <br />-- <br />-- <br />209/3 <br />1-4 <br />1. COORDINATE ELECTRICAL RECLUIREMENTSWITH ELECTRICAL DRAWINGS. <br />. VERIFY! AND SECURE EQUIPMENT MOUNTING ON ROOF AS NECESSARY. <br />3. MANUFACTURER PROVIDED 7-DAY PROGRAMMABLE THERMOSTAT. <br />. MANUFACTJRER PROVIDED DISCONNECT. <br />GRILLES, REGISTERS & DIFFUSERS <br />TAG <br />MANUFACTURER <br />MCIDEL <br />DESCRIPTION <br />SIZE <br />NECKSI7E DAMPER. <br />NOTES <br />SIB-1 TITUS TDCA•AA <br />LOUVERED FACE -AD1 24X24 AS NOTED NONE 1-4 <br />G-1 TITUS PAR -AA <br />PERF FACE 24X24 AS NOTED NONE 1-4 <br />NOTES: <br />L COORDINATE BORDER FRAME MOUNTING REQUIREMENTS WITH CEILING APPLICATION TYPE.. <br />2. MATERIAL SHALL BE ALUMINUM. <br />3. BALANCING DAMPER SHALL BE PROVIDED <br />AT GRILLES AND DIFFUSERS WHERE BRANCH DUCT CONNECTION IS NOT ACCESSIBLE. <br />4. COLOR AS SPECIFIED BY ARCHITECT. <br />BRANCH DUCT SIZING SCHEDULE <br />SUPPLY AIRFLOW <br />NECK .SIZE <br />RETURN AIRFLOW (CFM) <br />(CFM) <br />4"0 <br />0-50 <br />0-5 <br />51' <br />51-120 <br />51-100 <br />"� + <br />121- 210 <br />101- 175 <br />1000211- <br />321] .... <br />171 - 275 <br />"._.270- <br />1211 <br />_ <br />321.- 470 <br />400 <br />14" _ <br />471- 6 <br />401- 535 <br />16H p <br />1- 700 <br />536 - 700 <br />1. NECK 512E AS INDICATED IN TABLE ABOVE OR SHOWN ON PLANS. <br />DWAUST FAN SCHEDULE <br />MOTOR <br />TAG MANUFACTURER MODEL SERVICE TYPE CF ISP (in g SIP or RPM DRIVE INTERLOCK. 'BOLT, PH NOTES <br />EF-1 PENN BARRY ZEPHYR 7T PROPOSED RESTROOM-102 CEILING 75 0.375 48 W 1290 DIRECT LIGHT SWITCH 11554 1- <br />1. COORDINATE ELECTRICAL REQUIREMENTS WITH ELECTRICAL O, <br />2. MANUFACTURER PROVIDED O <br />3. MANUFACTURER PROVIDED BACKDRAFT <br />4 MANUFACTURER PROVIDED ELECTRONIC SPEED CONTROLLER. <br />5. MANUFACTURER PROVIDED TIME -DELAY SWITCH FOR, INTERLOCK WITH LIGHT. <br />6. MANUFACTURER PROVIDED: WALL CAP;. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN. <br />DUCTLESS SPLIT -SYSTEM SCHEDULES <br />TOTAL <br />MODEL (INDOOR/OUTDOOR) <br />M'Ca'04 ING mmmm <br />NOTES: <br />1. COOLING CAPACITYBASED O °F db 67 "F Wb INDOOR ENTERING AIR CONDITIONS. <br />. COOLING ONLY UNIT WITH LOW AMBIENT OPERATION. <br />. PROVIDE LITTLE GIANT CONDENSATE PUMP R APPROVED EQUAL). ROUTE CONDENSATE TO ADJACENT T ''ALL BOA. <br />4. MA UFA TURE:ER PROVIDED FILTER.. <br />5. STANDARD COOLINGONLY THERMOSTAT. <br />AT. <br />. PROVIDE LONG LI ". ESET KIT AS NEEDED PER MANUFACTURERS INSTALLATION INSTRUCTIONS. <br />7. AIRFLOW SCHEDULED, IS FOR, MEDIUM FAN SPEED. <br />www.brph.com Copyright © 2014 <br />Architects, Engineers <br />2727 Paces Ferry Road I Bldg 1 1 Suite 1800 <br />Atlanta I Georgia 1 30339 <br />770-933-9242 1 770-933-9246 f <br />Offices in Melbourne, Orlando, West Palm <br />Beach, Atlanta, Charleston, Seattle <br />These plans are protected by Federal Copyright <br />protection. Unauthorized use may result in an <br />infringement action. <br />ISSUE FOR PERMIT AND CONSTRUCTION <br />REVISION <br />0 <br />In <br />M <br />M <br />J <br />J <br />LL <br />— <br />J <br />_ <br />� <br />J <br />_ <br />z <br />Q <br />O <br />G <br />Q <br />J <br />= <br />W <br />N <br />_ <br />W <br />N <br />w <br />mi <br />M <br />W <br />J <br />J <br />W <br />W <br />V, <br />0 <br />r <br />o� <br />No. 37376 1 * _ <br />PROFFFSSIONAL Z: <br />ARCH/ENGR OF RECORD <br />BEN TRANWICK <br />FL PE 37376 <br />DESIGNED BY <br />CEJ <br />DRAWN BY <br />CEJ <br />CHECKED BY <br />JST <br />PROJECT NUMBER <br />C06898.057.00 <br />DATE <br />05/22/14 <br />TITLE <br />MECHANICAL <br />SCHEDULES <br />DRAWING NO. <br />M601 <br />1 <br />2 <br />K <br />`l <br />J <br />