Laserfiche WebLink
ABBREVIATIONS <br />PLUMBING SYMBOLS and LEGEND <br />GENERAL PLUMBING NOTES <br />C <br />❑C <br />fo <br />c <br />0 <br />ch <br />CIS <br />a) <br />NLO <br />LA0 <br />o� <br />�a. <br />0 <br />N <br />3 <br />'rn <br />0 <br />o <br />in <br />C\1 <br />� <br />i <br />N <br />U <br />—co <br />ABBR DESCRIPTION ABBR DESCRIPTION <br />AS <br />ABOVE SLAB <br />KW <br />KILOWATT <br />ADA <br />AMERICANS WITH DISABILITIES ACT <br />AFF <br />ABOVE FINISHED FLOOR <br />LAV <br />LAVATORY <br />AFG <br />ABOVE FINISHED GRADE <br />LF <br />LINEAR FEET <br />ANSI <br />AMERICAN NATIONAL STANDARDS INSTITUTE <br />AP <br />ACCESS PANEL <br />MAX <br />MAXIMUM <br />ASTM <br />AMERICAN STANDARDS TESTING MATERIALS <br />MIN <br />MINIMUM <br />AWWA <br />AMERICAN WATER WORKS ASSOCIATION <br />MNTG <br />MOUNTING <br />MS <br />MOP SINK <br />BFP <br />BACKFLOW PREVENTER <br />BS <br />BELOW SLAB <br />NA <br />NOT APPLICABLE <br />BFF <br />BELOW FINISH FLOOR <br />NC <br />NORMALLY CLOSED <br />NIC <br />NOT IN CONTRACT <br />CD <br />CONDENSATE <br />NO <br />NORMALLY OPEN <br />CO <br />CLEANOUT <br />NSF <br />NATIONAL SANITATION FOUNDATION <br />CONN <br />CONNECTION <br />NTS <br />NOT TO SCALE <br />CONT <br />CONTINUOUS <br />CP <br />CIRCULATING PUMP <br />OD <br />OUTSIDE DIAMETER <br />CV <br />CHECK VALVE <br />CW <br />COLD WATER <br />PDI <br />PLUMBING DRAINAGE INSTITUTE <br />PH <br />PHASE <br />DF <br />DRINKING FOUNTAIN <br />PPP <br />PRECISION PLUMBING PRODUCTS <br />DFU <br />DRAINAGE FIXTURE UNITS <br />PSI <br />POUNDS PER SQUARE INCH <br />DIA <br />DIAMETER <br />DN <br />DOWN <br />RPM <br />REVOLUTIONS PER MINUTE <br />DWG <br />DRAWING <br />RWL <br />RAIN WATER LEADER <br />ECO <br />EXTERIOR CLEANOUT <br />SAN <br />SANITARY <br />ELEV <br />ELEVATION <br />SAN U/G SANITARY UNDERGROUND <br />EQUIP <br />EQUIPMENT <br />SH <br />SHOWER <br />EWC <br />ELECTRIC WATER COOLER <br />SK <br />SINK <br />EWH <br />ELECTRIC WATER HEATER <br />SPEC <br />SPECIFICATION <br />EXIST <br />EXISTING <br />SQ <br />SQUARE <br />SS <br />STAINLESS STEEL <br />OF <br />DEGREES FAHRENHEIT <br />STD <br />STANDARD <br />FCO <br />FLOOR CLEANOUT <br />FD <br />FLOOR DRAIN <br />TDH <br />TOTAL DYNAMIC HEAD <br />FIN <br />FINISH <br />TEMP <br />TEMPERATURE <br />FL <br />FLOOR <br />TET <br />THERMAL EXPANSION TANK <br />FPS <br />FEET PER SECOND <br />TMV <br />THERMOSTATIC MIXING VALVE <br />FS <br />FLOOR SINK <br />TP <br />TRAP PRIMER <br />FT <br />FEET <br />TYP <br />TYPICAL <br />FU <br />FIXTURE UNITS <br />UL <br />UNDERWRITER'S LABORATORY <br />GAL <br />GALLON(S) <br />LINO <br />UNLESS NOTED OTHERWISE <br />GPM <br />GALLONS PER MINUTE <br />UR <br />URINAL <br />GW <br />GREASE WASTE <br />V <br />VOLTS <br />HB <br />HOSE BIBB <br />VTR <br />VENT THROUGH ROOF <br />HP <br />HORSEPOWER <br />VIV <br />VALVE IN VERTICAL <br />HR <br />HOUR <br />VLV <br />VALVE <br />HWR <br />HOT WATER RETURN <br />VOL <br />VOLUME <br />HZ <br />HERTZ <br />W <br />WATTS <br />IE <br />INVERT ELEVATION <br />W/ <br />WITH <br />ID <br />INTERNAL DIAMETER <br />WC <br />WATER CLOSET <br />IN <br />INCHES <br />WCO <br />WALL CLEANOUT <br />IPS <br />INTERNATIONAL PIPE STANDARD <br />WHA <br />WATER HAMMER ARRESTOR <br />IRR <br />IRRIGATION WATER <br />WHY <br />WALL HYDRANT <br />WFU <br />WATER SUPPLY FIXTURE UNITS <br />** NOT ALL ABBREVIATIONS ARE USED ** <br />CW <br />_ = HW <br />V <br />SAN <br />SAN <br />GR <br />W <br />KV=====___ <br />� FD <br />FCO <br />CO <br />GCO <br />low <br />** NOT ALL SYMBOLS ARE USED ** <br />DOMESTIC COLD WATER <br />HOT WATER TEMPERED (110F) <br />EXISTING PIPING <br />PIPING TO BE DEMOLISHED <br />VENT <br />SANITARY PIPE BELOW SLAB <br />SANITARY PIPE ABOVE SLAB <br />GREASE WASTE PIPE BELOW SLAB <br />WASTE PIPE BELOW SLAB <br />KITCHEN VENT <br />PIPE TURNING DOWN <br />PIPE TURNING UP <br />GATE or BALL VALVE <br />CHECK VALVE <br />HOSE BIBB <br />FLOOR DRAIN W/ TRAP PRIMER <br />FLOOR CLEANOUT <br />WALL CLEANOUT <br />GRADE CLEANOUT <br />SHOCK ABSORBER <br />DIRECTION OF FLOW (WATER) <br />DIRECTION OF SLOPE (SEWER) <br />PLUMBING FIXTURE NUMBER <br />HOT WATER MIXING VALVE <br />PRESSURE REDUCING VALVE (PRV) <br />BACKFLOW PREVENTER (BFP) <br />NON -FREEZE WALL HYDRANT (W.H.) <br />ROOF HYDRANT <br />1. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH 2O10 FLORIDA BUILDING CODE - PLUMBING. <br />2. ANCHOR EXPOSED VERTICAL WATER PIPES TO WALLS WITH HOT -DIPPED GALVANIZED UNI-STRUT CHANNELS AND CUSHIONED/SHOULDER BOLT CLAMP. <br />3. INSTALL HORIZONTAL EXPOSED PIPES AS CLOSE TO THE CEILING AS POSSIBLE. <br />4. CONTRACTOR SHALL COORDINATE ACTUAL LOCATIONS OF MECHANICAL FLOOR DRAINS AND CONDENSATE DRAINS WITH HVAC FINAL EQUIPMENT LOCATIONS ON SHOP DRAWING <br />5. PROVIDE AND INSTALL WATER HAMMER ARRESTORS IN ALL HW AND CW SUPPLY PIPING IN ACCORDANCE WITH PDI-WH2O1 STANDARDS. SEE SCHEDULE FOR <br />SIZES. AIR CHAMBERS ARE NOT ACCEPTABLE SUBSTITUTIONS. COORDINATE ACCESS PANEL OR PROVIDE SIOUX CHIEF MODEL WHICH DOES NOT REQUIRED <br />ACCESS PANELS. <br />6 THE DRAWINGS ARE GENERALLY INDICATIVE OF THE WORK TO BE INSTALLED AND DO NOT INDICATE ALL OFFSETS, FITTINGS AND SIMILAR DETAILS WHICH MAY <br />BE REQUIRED. THE CONTRACTOR SHALL CAREFULLY INVESTIGATE THE STRUCTURAL AND FINISH CONDITIONS AFFECTING ALL WORK AND ARRANGE <br />ACCORDINGLY, FINISHING SUCH OFFSETS, FITTINGS, VALVES AND OTHER SIMILAR DETAILS AS MAY BE REQUIRED TO MEET SUCH OFFSETS. <br />7. CONTRACTOR SHALL BE RESPONSIBLE UNDER THIS SPECIFICATION FOR THE PROPER COORDINATION OF ALL WORK WITH THE RELATED WORK OF OTHER TRADES, CRAFTS, <br />CONTRACTORS, SUBCONTRACTORS, ETC. EMPLOYED ON THE PROJECT, TO INSURE A COMPLETE NEAT AND WORKMANLIKE INSTALLATION. <br />8. THOROUGHLY READ SPECIFICATIONS BEFORE STARTING WORK OR ORDERING MATERIALS. <br />9. DO NOT INSTALL PIPING ABOVE ELECTRICAL PANELS, SWITCHGEAR THROUGH ELECTRICAL AND DATA ROOMS. <br />10. ALL SANITARY PIPING 2-1/2" OR LESS SHALL BE SLOPED AT 1/4" PER FOOT. ALL SANITARY PIPING 3" & LARGER SHALL BE SLOPED AT 1/8" PER FT. MINIMUM. <br />11. VERIFY LOCATIONS & SIZES OF EXISTING SITE UTILITIES BEFORE COMMENCING WORK. <br />12. PLUMBING SYSTEM VENTS THROUGH ROOF TO BE TEN FEET (MINIMUM) FROM HVAC FRESH AIR INTAKES (OR ROOF TOP UNITS) AND WINDOW OPENINGS. <br />13. PAINT EXPOSED PIPING TO MATCH SURROUNDINGS. COORDINATE EXACT REQUIREMENTS WITH SPECIFICATION AND/OR ARCHITECT. <br />14. MANUFACTURER'S AND MODELS NUMBERS FOR PLUMBING EQUIPMENT ARE BASIS OF DESIGN. APPROVED EQUIVALENTS ARE PERMITTED. <br />15. COORDINATE ALL CEILING PIPING ELEVATIONS IN SHOP DRAWINGS WITH HVAC, FIRE PROTECTION AND ELECTRICAL TRADES TO ENSURE CLEARANCES AND PENETRATIONS, <br />PRIOR TO INSTALLATION. <br />16. ALL VALVES SHALL BE LOCATED IN ACCESSIBLE AREAS AS DEFINED BY THE FLORIDA PLUMBING CODE. CONTRACTOR SHALL PROVIDE ACCESS DOORS WHERE <br />NECESSARY. (12"X12" MIN.) <br />17. COORDINATE ALL PLUMBING EQUIPMENT/FIXTURE REQUIREMENTS WITH THE CASEWORK DRAWINGS. <br />18• VALVES AND FITTINGS SHALL BE THE SAME SIZE AS THE PIPING WHERE THEY ARE LOCATED UNLESS NOTED OTHERWISE. <br />19. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY SUPPORTING DEVICES FOR ALL FIXTURES INCLUDED IN THIS CONTRACT OR SPECIFIED HEREIN. <br />PLUMBING FIXTURE SCHEDULE <br />MARK <br />DESCRIPTION <br />WASTE <br />VENT <br />CW <br />HW <br />FLOW <br />ELECTRICAL <br />MANUFACTURER <br />MODEL <br />REMARKS <br />TWO PIECE FLOOR MOUNTED, ELONGATED, ADA COMPLIANT. PROVIDE WITH OLSONITE 10CT TOILET SEAT. <br />P-1 <br />WATER CLOSET <br />4" <br />2" <br />3/4" <br />--- <br />1.6 GALLONS/FLUSH <br />------- <br />SLOAN <br />WETS 9023-1.6 <br />_______ <br />WALL HUNG LAVATORY, ADA COMPLIANT 4" CENTER. <br />P-2 <br />LAVATORY <br />1-1/4" <br />2" <br />1/2" <br />1/2" <br />0.5 GPM <br />SLOAN <br />SS-3003-4" <br />FAUCET: CHICAGO MODEL 420-E2805ABCP <br />------- <br />HIGH IMPACT POLYSTYRENE, 2 SUPPORT BRACKETS, SNAP -ON FACEPLATE FRAME W ZURN Z1024 FIXED AIR GAP, <br />P-3 <br />CONDENSATE <br />1-1/4" <br />2" <br />----- <br />----- <br />----- <br />OATEY <br />38751 <br />DURA COATED CAST IRON BODY WITH SLIP JOINT INLET AND NPT OUTLET <br />WALL BOX <br />1 <br />�j <br />ELECTRIC WATER HEATER SCHEDULE <br />STORAGE <br />MANUFACTURER <br />INLET SIZE <br />OUTLET <br />ELECTRICAL <br />ROOM <br />TAG <br />(GALS) <br />& MODEL # <br />(IN.) <br />S SIZE <br />(IN) <br />NUMBER <br />V <br />PH <br />HZ <br />AMPS <br />KW <br />EWH-1 <br />NA <br />EEMAX <br />SP3208 <br />1/2" <br />112" <br />208 <br />1 <br />60 <br />15 <br />3 <br />RESTROOM 102 <br />3 <br />WATER HAMMER SCHEDULE <br />ARRESTOR SIZE (WHA) <br />WATER SUPPLY FIXTURE <br />UNITS <br />PDI STD WH 201 <br />1/2" <br />1-11 <br />PDI-A <br />3/4" <br />12-32 <br />PDI-B <br />ill <br />33-60 <br />PDI-C <br />1-1/4" <br />61-133 <br />PDI-D <br />1-1/2" <br />114-154 <br />PDI-E <br />2" <br />155-330 <br />PDI-F <br />NOTE: <br />ALL ARRESTORS SHALL BE INSTALLED PER PDI (PLUMBING AND DRAINAGE INSTITUTE) STANDARD PDI- <br />WH2O1 (2006) FOR SIZING AND PLACEMENT. <br />PLUMBING SPECIFICATIONS <br />GENERAL <br />THE GENERAL MECHANICAL SPECIFICATIONS APPLY TO THE WORK SPECIFIED IN THIS <br />SECTION. <br />SCOPE OF WORK <br />PROVIDE A COMPLETE PLUMBING SYSTEM AS INDICATED ON THE DESIGN DRAWINGS AND <br />AS OUTLINED WITHIN THESE SPECIFICATIONS. WORK SHALL INCLUDE BUT NOT BE <br />LIMITED TO SELECTIVE DEMOLITION, THE FABRICATION AND/OR INSTALLATION OF THE <br />SCHEDULED PLUMBING FIXTURES AND RELATED PIPING. THE COMPLETED PLUMBING <br />SYSTEM SHALL MEET ALL APPLICABLE CODES AND STANDARDS. <br />WATER SUPPLY SYSTEM: <br />PROVIDE SHOCK ABSORBERS AND VACUUM BREAKERS WHERE REQUIRED. <br />PIPE AND FITTINGS ABOVE SLAB - TYPE L HARD COPPER, ASTM B88 AND WROUGHT <br />COPPER SOLDER -JOINT FITTINGS AND BRAZED JOINTS. (USE ONLY "LEAD FREE" SOLDER).. <br />PIPE AND FITTINGS BELOW SLAB - TYPE "K" SOFT COPPER. ASTM B88 AND WROUGHT <br />COPPER, SOLDER JOINT FITTINGS AND BRAZED JOINTS. PROVIDE POLYBUTYLENE WRAPPING. <br />VALVES (2-1/2 INCH AND SMALLER) TWO PIECE 400 PSI WSP FULL PORT BRONZE <br />BODY BALL VALVE WITH THREADED ENDS, LOCKABLE LEVER HANDLE AND REPLACEABLE <br />TEFLON OR TFE SEATS <br />CHLORINATION - BEFORE BEING PLACED IN SERVICE ALL WATER DISTRIBUTION SYSTEMS <br />SHALL BE STERILIZED WITH CHLORINE IN ACCORDANCE WITH PLUMBING CODE AND AWWA <br />C-651 OR C-652 STANDARD PROCEDURE FOR DISINFECTING WATER MAINS. <br />SHOCK ARRESTOR: MIFAB, SIOUX CHIEF OR EQUAL <br />DRAINAGE SYSTEM: <br />EXTEND PIPING FROM NEW FIXTURES AND EQUIPMENT AND CONNECT TO SYSTEMS AS <br />INDICATED ON THE DRAWINGS. <br />PIPE SLOPE: <br />2-1/2 INCH DIAMETER AND LESS SHALL BE INSTALLED WITH A FALL OF NOT LESS THAN 1/4 INCH PER <br />FOOT. <br />3 INCH DIAMETER OR LARGER SHALL BE INSTALLED WITH A FALL NOT LESS THAN 1/8 <br />INCH PER FOOT. <br />PROVIDE CLEANOUTS EVERY 75 FEET, AT CHANGES IN DIRECTION, AT BASE OF <br />DOWNSPOUTS AND AT BASE OF SOIL AND WASTE STACKS. <br />WALL CLEANOUT: MIFAB, ZURN, JONESPEC, JOSAM OR EQUAL. <br />FLOOR CLEANOUT: MIFAB, ZURN, JONESPEC, JOSAM OR EQUAL. <br />VENTS SHALL BE EXTENDED TO EXTERIOR OF BUILDING. AIR ADMITTANCE VALVES ARE <br />NOT ACCEPTABLE. <br />PIPE AND FITTINGS ABOVE SLAB -HUBLESS CAST IRON SOIL PIPE AND CISPI HUBLESS <br />PIPING COUPLINGS AND COUPLED JOINTS. <br />PIPE AND FITTINGS BELOW SLAB - SERVICE CLASS - CAST IRON SOIL PIPING AND <br />GASKETED JOINTS. <br />5 I 6 <br />www.brph.com Copyright © 2014 <br />Architects, Engineers <br />2727 Paces Ferry Road I Bldg 1 I Suite 1800 <br />Atlanta I Georgia 1 30339 <br />770-933-9242 1 770-933-9246 f <br />Offices in Melbourne, Orlando, West Palm <br />Beach, Atlanta, Charleston, Seattle <br />These plans are protected by Federal Copyright <br />protection. Unauthorized use may result in an <br />infringement action. <br />ISSUE FOR PERMIT AND CONSTRUCTION <br />REVISION L <br />1♦ <br />M� <br />W <br />5O <br />G <br />W <br />Z <br />O <br />V <br />w <br />0. <br />W <br />U) <br />w % 11111,,, <br />�,�C•,�Sf•F7F.� <br />No. 37376 1 <br />PROFESSIONAL <br />ARCH/ENGR OF RECORD <br />BENJAMIN E. TRAWICK, JR. <br />FL PE 37376 <br />DESIGNED BY <br />BDS <br />DRAWN BY <br />BIDS <br />CHECKED BY <br />BET <br />PROJECT NUMBER <br />C06898.057.01 <br />DATE <br />08/12/14 <br />TITLE <br />PLUMBING <br />LEGENDS AND <br />SCHEDULES <br />DRAWING NO. <br />Pool <br />