<br />ELECTRICAL LEGEND
<br />LIGHTING
<br />O
<br />DOWNLIGHT
<br />0-
<br />WALL MOUNTED FLUORESCENT OR
<br />INCANDESCENT LUMINAIRE, AS NOTED
<br />--�
<br />CEILING OR WALL MOUNTED HID LUMINAIRE
<br />@K
<br />PORCELAIN KEYLESS
<br />®
<br />SURFACE MOUNTED FLUORESCENT LUMINAIRE
<br />0
<br />RECESS MOUNTED FLUORESCENT LUMINAIRE
<br />RECESS MOUNTED FLUORESCENT LUMINAIRE (EMERGENCY)
<br />�-a-�
<br />FLUORESCENT STRIP LUMINAIRE
<br />Q__=
<br />TRACK LIGHT, AS NOTED OR SCHEDULED
<br />p
<br />DIRECTIONAL ACCENT OR WALL -WASH LUMINAIRE
<br />❑_0_❑
<br />EXTERIOR POLE MOUNTED LUMINAIRE, AS SCHEDULED
<br />❑
<br />BOLLARD
<br />®
<br />CEILING OR WALL MOUNTED EXIT SIGN, INSTALL
<br />FACES AS INDICATED BY SHADING
<br />EMERGENCY LIGHT AS NOTED
<br />SWITCHING
<br />$
<br />WALL MOUNTED SWITCH
<br />SUBSCRIPTS:
<br />2 = DOUBLE POLE
<br />3 = 3-WAY
<br />4 = 4-WAY
<br />D = DIMMER
<br />K = KEY -OPERATED
<br />0 = SWITCH MOUNTED OCCUPANCY SENSOR
<br />P = PILOT LIGHT
<br />T= THERMAL OVERLOAD
<br />LV = LOW VOLTAGE
<br />DS = DOOR SWITCH
<br />M = MOTOR RATED SWITCH
<br />OS
<br />CEILING MOUNTED OCCUPANCY SENSOR
<br />POWER
<br />STRAIGHT BLADE DUPLEX RECEPTACLE
<br />SUBSCRIPTS:
<br />HG = HOSPITAL GRADE
<br />HGT = HOSPITAL GRADE TAMPER RESISTANT
<br />GFI = GROUND FAULT INTERRUPTER
<br />SS = SURGE SUPRRESSION
<br />AC = 6" ABOVE COUNTER
<br />STRAIGHT BLADE DOUBLE DUPLEX RECEPT. (FOURPLEX)
<br />e-
<br />STRAIGHT BLADE SINGLE RECEPTACLE
<br />STRAIGHT BLADE DUPLEX RECEPT. HALF -SWITCHED
<br />STRAIGHT BLADE DUPLEX RECEPT. ON EMERGENCY CIRCUIT
<br />®
<br />OUTLET WITH SPECIAL DEVICE, AS NOTED
<br />WALL MOUNTED OUTLET WITH SPECIAL DEVICE, AS
<br />NOTED
<br />®
<br />FLOOR MOUNTED QUAD RECEPTACLE, AS NOTED
<br />®
<br />FLOOR MOUNTED DUPLEX RECEPTACLE, AS NOTED
<br />PEI
<br />FLOOR MOUNTED COMBINATION OUTLET BOX, AS
<br />NOTED
<br />®
<br />STRAIGHT BLADE DUPLEX RECEPTACLE, CEILING
<br />OO
<br />POKE THROUGH, AS NOTED
<br />O
<br />PEDESTAL OUTLET, AS NOTED
<br />❑J
<br />JUNCTION BOX AS NOTED
<br />(
<br />OUTLET BOX
<br />( H
<br />WALL MOUNTED OUTLET BOX
<br />�D
<br />ABOVE CEILING POWER DISTRIBUTION BOX
<br />SURFACE RACEWAY, AS NOTED
<br />TELE-POWER POLE
<br />PB
<br />PULL BOX
<br />OM
<br />CONNECTION TO MOTOR
<br />®
<br />MAGNETIC MOTOR STARTER
<br />SUBSCRIPTS:
<br />MS = MULTISPEED
<br />SSRV = SOLID-STATE, REDUCED VOLTAGE
<br />VF = VARIABLE FREQUENCY
<br />OT
<br />WALL MOUNTED OUTLET BOX FOR THERMOSTAT
<br />NOTE: ALL SYMBOLS SHOWN ON LEGEND
<br />ARE NOT NECESSARILY USED.
<br />LS
<br />SAFETY DISCONNECT SWITCH (NON -FUSED)
<br />FIRE ALARM SYSTEM
<br />FUSED DISCONNECT SWITCH, 30/3/l/NF INDICATES
<br />FACP
<br />FIRE ALARM CONTROL PANEL
<br />30AMP FRAME, 3-POLE, NEMA 1, NON -FUSED
<br />FAGP
<br />N
<br />COMBINATION DISCONNECT AND STARTER
<br />0
<br />FIRE ALARM GRAPHIC PANEL
<br />ENCLOSED CIRCUIT BREAKER, MOLDED -CASE,
<br />FAAP
<br />FIRE ALARM ANNUNCIATOR PANEL
<br />THERMAL -MAGNETIC
<br />Q
<br />MANUAL PULL STATION
<br />SUBSCRIPTS:
<br />FIRE ALARM STROBE
<br />AT = ADJUSTABLE TRIP
<br />��
<br />ED<
<br />GENERAL ALARM COMBINATION HORN/STROBE
<br />EAT = ELECTRONIC ADJUSTABLE TRIP
<br />l<
<br />FIRE ALARM HORN
<br />CL = CURRENT LIMITING
<br />CEILING OR WALL MOUNTED DETECTOR
<br />IF = INTEGRALLY FUSED
<br />SUBSCRIPTS:
<br />GFCI = GROUND FAULT CIRCUIT INTERRUPTER
<br />I = IONIZATION
<br />ST = SHUNT TRIP
<br />T = THERMAL, FIXED AND RATE -OF -RISE
<br />KI = KEY INTERLOCK
<br />TF = THERMAL, FIXED
<br />ZSI = ZONE -SELECTIVE INTERLOCKING
<br />T165° =165`F THERMAL, FIXED AND RATE -OF -RISE
<br />CONNECTION TO PRE -WIRED EQUIPMENT
<br />TF165° =165°F THERMAL, FIXED
<br />0
<br />BREAKER PANEL
<br />P = PHOTOELECTRIC
<br />MCC
<br />MOTOR CONTROL CENTER
<br />PT = COMBINATION PHOTOELECTRIC AND THERMAL
<br />FSS_1
<br />TRANSIENT VOLTAGE SURGE SUPPRESSOR
<br />S = SMOKE
<br />IDTRANSFORMER
<br />OD
<br />SMOKE DETECTOR IN VENTILATING DUCT
<br />Rd
<br />ENGINE GENERATOR
<br />A
<br />FAN SHUT -DOWN CONNECTION
<br />Q
<br />MAG. DOOR HOLDER
<br />TC
<br />TIME CLOCK
<br />(Z>
<br />SPRINKLER SYSTEM FLOW SWITCH
<br />C1
<br />LIGHTING CONTACTOR; NUMERAL INDICATES CONTACTOR NUMBER.
<br />SPRINKLER SYSTEM TAMPER SWITCH
<br />OFIREFIGHTERS
<br />TELEPHONE JACK
<br />CIRCUITING
<br />© F
<br />LIFE SAFETY SPEAKER
<br />CONDUIT RUN
<br />ED<
<br />LIFE SAFETY SPEAKER WITH STROBE
<br />CIRCUIT HOMERUN TO PANEL OR CABINET, NO.
<br />p O-I
<br />REMOTE PILOT LIGHT
<br />OF ARROWS INDICATE NO. OF CIRCUITS.
<br />WHERE SHOWN, HASH MARKS DENOTE THE
<br />P�O-I
<br />REMOTE PILOT LIGHT WITH TEST SWITCH
<br />FOLLOWING: '%" = HOT; 'r" = NEUTRAL;
<br />GROUND
<br />MONITOR MODULE
<br />--0
<br />CIRCUIT TURNED UP
<br />�
<br />CONTROL MODULE
<br />CIRCUIT TURNED DOWN
<br />®
<br />DAMPER CONNECTION
<br />— 3
<br />CONDUIT STUB -OUT - CAP & MARK
<br />CIRCUIT IN FLEXIBLE CONDUIT
<br />COMMUNICATION SYSTEM
<br />SEALOFF
<br />In
<br />FLOOR MOUNTED TELEPHONE AND/OR DATA
<br />- _ _ _ _ _ -
<br />CONDUIT BELOW FLOOR
<br />OUTLET BOX, AS NOTED
<br />-
<br />SWITCHED POWER CIRCUIT. SEE
<br />WALL MOUNTED TELEPHONE OUTLET
<br />NOTE 14 ON SHEET E200.
<br />0
<br />WALL MOUNTED DATA OUTLET
<br />0
<br />WALL MOUNTED COMBINATION
<br />SCHEMATIC WIRING GRAPHICS
<br />TELEPHONE/DATA OUTLET BOX
<br />METER
<br />W
<br />WALL MOUNTED AT 48" WITH MOUNTING BRACKET
<br />GROUND CONNECTION AS NOTED
<br />—�
<br />FUSED DISCONNECT SWITCH
<br />Q QS -I CEILING OR WALL MOUNTED SPEAKER
<br />-1 lvr
<br />FUSES
<br />a
<br />VOLUME CONTROL
<br />d �
<br />MAGNETIC MOTOR STARTER
<br />O V
<br />FLOOR OR WALL MOUNTED MICROPHONE OUTLET
<br />SUBSCRIPTS:
<br />C
<br />CALL -IN SWITCH
<br />MS = MULTISPEED
<br />S J
<br />TIME -TONE UNIT
<br />SSRV = SOLID-STATE, REDUCED VOLTAGE
<br />JQ CEILING OR WALL MOUNTED CLOCK
<br />VF = VARIABLE FREQUENCY
<br />©-I
<br />DOOR BELUCHIME
<br />ENCLOSED CIRCUIT BREAKER, MOLDED -CASE,
<br />©
<br />BUZZER
<br />THERMAL -MAGNETIC
<br />O
<br />HOUSE PHONE/INTERCOM
<br />SUBSCRIPTS:
<br />OI
<br />MASTER INTERCOM STATION
<br />AT = ADJUSTABLE TRIP
<br />TV
<br />TELEVISION ANTENNA OUTLET
<br />EAT = ELECTRONIC ADJUSTABLE TRIP
<br />CC
<br />CLOSED CIRCUIT TV OUTLET
<br />CL =CURRENT LIMITING
<br />Cad
<br />COAX OUTLET
<br />IF = INTEGRALLY FUSED
<br />AMPLIFIER
<br />GFCI = GROUND FAULT CIRCUIT INTERRUPTER
<br />V
<br />ST = SHUNT TRIP
<br />a
<br />TEMPERATURE SENSOR
<br />KI = KEY INTERLOCK
<br />ZSI = ZONE -SELECTIVE INTERLOCKING
<br />POWER TRANSFORMER
<br />NOTATIONS
<br />-
<br />CURRENT TRANSFORMER
<br />1-
<br />UPPER CASE LETTER AT LUMINAIRES (F1,11, ETC.)
<br />Q
<br />AMMETER
<br />INDICATES LUMINAIRE TYPE. LUMINAIRES IN AREA
<br />OV
<br />INDICATED. WHERE NOTED, NUMBER ADJACENT TO
<br />VOLT METER
<br />LUMINAIRE TYPE INDICATES CIRCUIT NUMBER FOR
<br />THAT LUMINAIRE (E.G., F1/27)
<br />TRANSFER SWITCH.
<br />GF
<br />2-
<br />LOWER CASE LETTER AT LUMINAIRES AND SWITCHES
<br />GROUND FAULT PROTECTION
<br />(a, b, ETC.) INDICATE ASSOCIATED UNITS FOR
<br />G
<br />GENERATOR
<br />3-
<br />SWITCHING.
<br />DIAGONAL WITHIN LUMINAIRE DENOTES UNIT ON
<br />EMERGENCY (EM) CIRCUIT WITH BATTERY.
<br />3
<br />MOTOR, NUMBER INDICATES HORSEPOWER
<br />4-
<br />"NL" WITHIN LUMINAIRES DENOTES UNIT ON NIGHT
<br />LIGHT CIRCUIT.
<br />PP
<br />LIGHTING CONTROL POWER PACK
<br />5-
<br />PLUS (+) SIGN WITH DIMENSION AT OUTLET
<br />-I
<br />CONTACTOR
<br />INDICATES HEIGHT ABOVE FINISHED FLOOR OR
<br />GRADE TO CENTERLINE OF OUTLET.
<br />ABBREVIATIONS
<br />NOTE: ALL ABBREVIATIONS SHOWN ON
<br />LEGEND ARE NOT NECESSARILY USED.
<br />AC
<br />- ABOVE COUNTER
<br />AFC
<br />- ABOVE FINISHED CEILING
<br />AFF
<br />-ABOVE FINISHED FLOOR
<br />AFG
<br />-ABOVE FINISHED GRADE
<br />AIC
<br />-AMPS INTERRUPTING CURRENT
<br />AL
<br />-ALUMINUM
<br />BFG
<br />- BELOW FINISHED GRADE
<br />CB
<br />- CIRCUIT BREAKER
<br />CR
<br />- CORROSION RESISTANT
<br />CT
<br />- CURRENT TRANSFORMER
<br />CU
<br />-COPPER
<br />DISC
<br />- DISCONNECT
<br />EM
<br />-EMERGENCY
<br />ES
<br />- EMERGENCY STOP
<br />EWC
<br />- ELECTRIC WATER COOLER
<br />EX
<br />- EXISTING
<br />FLA
<br />- FULL LOAD AMPS
<br />FVNR
<br />- FULL VOLTAGE, NON -REVERSING
<br />FVR
<br />- FULL VOLTAGE, REVERSING
<br />FWE
<br />- FURNISHED WITH EQUIPMENT
<br />GFI
<br />- GROUND FAULT INTERRUPTER
<br />GRC
<br />- GALVANIZED RIGID CONDUIT
<br />HOA
<br />- HAND -OFF -AUTOMATIC
<br />HP
<br />-HORSEPOWER
<br />IG
<br />-ISOLATED GROUND
<br />LC
<br />- LIGHTING CONTACTOR
<br />MCA
<br />- MINIMUM CIRCUIT AMPS
<br />MCB
<br />- MAIN CIRCUIT BREAKER
<br />MCC
<br />- MOTOR CONTROL CENTER
<br />MCP
<br />- MOTOR CIRCUIT PROTECTION
<br />MLO
<br />- MAIN LUGS ONLY
<br />NC
<br />- NORMALLY CLOSED
<br />NIC
<br />- NOT IN CONTRACT
<br />NL
<br />- NIGHT LIGHT
<br />NO
<br />- NORMALLY OPEN
<br />NTS
<br />- NOT TO SCALE
<br />OC
<br />- OVER CURRENT
<br />OL
<br />-OVERLOAD
<br />PART
<br />- PARTIAL CIRCUIT
<br />POS
<br />- POINT OF SALES
<br />TTB
<br />- TELEPHONE TERMINAL BOARD
<br />UG
<br />-UNDERGROUND
<br />WG
<br />- WIREGUARD
<br />WP
<br />-WEATHERPROOF
<br />WSHP
<br />- WATER SOURCE HEAT PUMP
<br />XFMR
<br />-TRANSFORMER
<br />THESE DRAWINGS ARE DIAGRAMMATIC -
<br />REFER TO ARCHITECTURAL DRAWINGS FOR
<br />EXACT DIMENSIONS. BRANCH CIRCUITING
<br />CONVENTION - #12 AWG PER PHASE AND
<br />NEUTRAL (WHERE REQUIRED) AND 20 AMPERE
<br />CIRCUIT BREAKER, UNLESS OTHERWISE
<br />NOTED. PROVIDE QUANTITY AND SIZE
<br />SWITCH CONDUCTORS AS REQUIRED TO MAKE
<br />SYSTEM OPERATIONAL.
<br />GENERAL NOTES (FOR ALL ELECTRICAL SHEETS)
<br />1. COORDINATE LOCATION OF LUMINAIRES WITH ARCHITECTURAL REFLECTED CEILING
<br />PLANS.
<br />2. 3 AND 4 LAMP FIXTURES SHOWN WITH DIAGONAL SHALL HAVE INBOARD LAMP
<br />CONNECTED TO EMERGENCY BATTERY PACK. SEE SPECIFICATIONS.
<br />3. PROVIDE (1) 3/4"C. (MIN) WITH PULL WIRE FROM EACH TELEPHONE, DATA OR
<br />COMMUNICATION OUTLET SHOWN, TO ABOVE ACCESSIBLE CEILING, AND CAP.
<br />4. COORDINATE EXACT EQUIPMENT LOCATIONS WITH OWNER PRIOR TO ROUGH -INS.
<br />5. COORDINATE LOCATION OF ALL OUTLETS WITH ARCHITECTURAL ELEVATIONS,
<br />CASEWORK SHOP DRAWINGS AND EQUIPMENT INSTALLATION DRAWINGS.
<br />6. COORDINATE LOCATION OF MECHANICAL EQUIPMENT WITH MECHANICAL PLANS
<br />AND MECHANICAL CONTRACTOR PRIOR TO ROUGH -IN.
<br />7. ANY ITEMS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE
<br />CONTRACTOR.
<br />8. ALL 120V BRANCH CIRCUITS SHALL BE 3-WIRE (PHASE, NEUTRAL, GROUND).
<br />9. CONTRACTOR SHALL NOT ROUTE ANY CONDUIT WITHIN STRUCTURAL OR TOPPING
<br />SLABS OF FLOORS UNLESS NOTED TO DO SO.
<br />10. REFER TO ARCHITECTURAL PLANS, ELEVATIONS AND DIAGRAMS FOR LOCATIONS
<br />OF FLOOR DEVICES AND WALL DEVICES. LOCATION WILL INDICATE VERTICAL AND/
<br />OR HORIZONTAL MOUNTING. IF DEVICES ARE NOT NOTED OTHERWISE THEY SHALL
<br />BE MOUNTED LONG AXIS VERTICAL AT +16" TO CENTER.
<br />11. INFORMATION ON THE DRAWINGS HAS BEEN ASCERTAINED FROM INFORMATION
<br />PROVIDED BY OTHERS. THIS INFORMATION IS AS ACCURATE AS
<br />CONDITIONS WOULD ALLOW. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
<br />VISIT THE SITE, PRIOR TO BID, AND FAMILIARIZE HIMSELF WITH THE EXTENT OF
<br />REMODEL WORK REQUIRED. NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF
<br />A FORESEEABLE NATURE REQUIRED TO ACHIEVE THE END RESULT AS INDICATED
<br />BY CONTRACT DOCUMENTS.
<br />12. ALL NEW WIRING REQUIRED BY TENANT BUILDOUT SHALL BE FISHED THROUGH
<br />EXISTING WALLS OR CONCEALED IN NEW WALLS OR ABOVE CEILINGS. SURFACE
<br />MOUNTED CONDUIT SHALL NOT BE USED IN ANY FINISHED AREAS.
<br />13. MAINTAIN CIRCUIT CONTINUITY FOR ALL EXISTING ITEMS THAT ARE REMAINING OR
<br />BEING RELOCATED.
<br />14. PROVIDE UPDATED PANEL DIRECTORIES FOR ALL EXISTING PANELS BEING
<br />AFFECTED BY REMODEL WORK CIRCUIT NUMBERS SHOWN MAY NOT REFLECT
<br />ACTUAL FIELD CONDITIONS. PROVIDE NEW CIRCUIT BREAKER NUMBER
<br />IDENTIFICATION AS REQUIRED.
<br />15. ALL ITEMS SHOWN TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY
<br />INCLUDING ALL ASSOCIATED CONDUIT AND WIRE BACK TO POINT OF ORIGIN OR
<br />NEAREST EXISTING ITEM THAT IS REMAINING, UNLESS OTHERWISE NOTED.
<br />16. WHERE EXISTING DEVICES, SWITCHES, MOTOR CONNECTIONS, ETC. ARE TO BE
<br />REMOVED FROM WALLS WHICH ARE REMAINING, WALLS SHALL BE PATCHED TO
<br />MATCH ORIGINAL FINISH, AFTER CONDUCTORS HAVE BEEN REMOVED. BLANK
<br />COVERPLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE.
<br />17. IF EXISTING CONDUITS ARE ROUTED IN CONCRETE FLOOR SLABS, CONCRETE
<br />WALLS OR CONCRETE CEILINGS, THEY SHALL BE CUT BACK TO WITHIN CONCRETE
<br />AND FILLED WITH GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH FLUSH WITH
<br />CONCRETE SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED.
<br />www.brph.com Copyright © 2014
<br />Architects, Engineers, Inc.
<br />2727 Paces Ferry Road I Bldg 1 I Suite 1800
<br />Atlanta I Georgia 1 30339
<br />770-933-9242 1 770-933-9246 f
<br />Offices in Melbourne, Orlando, West Palm
<br />Beach, Atlanta, Charleston, Seattle
<br />These plans are protected by Federal Copyright
<br />protection. Unauthorized use may result in an
<br />infringement action.
<br />ISSUE FOR PERMIT AND CONSTRUCTION
<br />REVISION
<br />r
<br />In
<br />J
<br />M
<br />J
<br />LL.
<br />—
<br />W
<br />J
<br />J
<br />Z
<br />—
<br />O
<br />M
<br />W
<br />J
<br />=
<br />�—
<br />V
<br />Qom,
<br />w
<br />1
<br />�
<br />�w^
<br />�
<br />J
<br />W
<br />Q
<br />N011.
<br />t�
<br />r
<br />ARCH/ENGR OF RECORD
<br />JOHN D. ADDISON
<br />FL PE #59239
<br />DESIGNED BY
<br />JAH
<br />DRAWN BY
<br />JAH
<br />CHECKED BY
<br />JDA
<br />PROJECT NUMBER
<br />C06898.057.01
<br />DATE
<br />08/13/14
<br />TITLE
<br />ELECTRICAL
<br />LEGEND
<br />DRAWING NO.
<br />1
<br />3 4
<br />5