Laserfiche WebLink
I <br />IC <br />C <br />R <br />C <br />O <br />a) <br />C <br />a) <br />0 <br />NI <br />U <br />a) <br />LU i <br />D_ <br />D� <br />L <br />C <br />C- <br />m <br />N <br />0 <br />~A <br />LO <br />0 <br />co <br />m <br />00 <br />(0 <br />U) <br />C <br />U <br />O <br />o 2 <br />C (_ <br />O <br />a) <br />C C9 <br />a)NT <br />d <br />r <br />`) o <br />Z) M <br />ELECTRICAL LEGEND <br />LIGHTING <br />O <br />DOWNLIGHT <br />0- <br />WALL MOUNTED FLUORESCENT OR <br />INCANDESCENT LUMINAIRE, AS NOTED <br />--� <br />CEILING OR WALL MOUNTED HID LUMINAIRE <br />@K <br />PORCELAIN KEYLESS <br />® <br />SURFACE MOUNTED FLUORESCENT LUMINAIRE <br />0 <br />RECESS MOUNTED FLUORESCENT LUMINAIRE <br />RECESS MOUNTED FLUORESCENT LUMINAIRE (EMERGENCY) <br />�-a-� <br />FLUORESCENT STRIP LUMINAIRE <br />Q__= <br />TRACK LIGHT, AS NOTED OR SCHEDULED <br />p <br />DIRECTIONAL ACCENT OR WALL -WASH LUMINAIRE <br />❑_0_❑ <br />EXTERIOR POLE MOUNTED LUMINAIRE, AS SCHEDULED <br />❑ <br />BOLLARD <br />® <br />CEILING OR WALL MOUNTED EXIT SIGN, INSTALL <br />FACES AS INDICATED BY SHADING <br />EMERGENCY LIGHT AS NOTED <br />SWITCHING <br />$ <br />WALL MOUNTED SWITCH <br />SUBSCRIPTS: <br />2 = DOUBLE POLE <br />3 = 3-WAY <br />4 = 4-WAY <br />D = DIMMER <br />K = KEY -OPERATED <br />0 = SWITCH MOUNTED OCCUPANCY SENSOR <br />P = PILOT LIGHT <br />T= THERMAL OVERLOAD <br />LV = LOW VOLTAGE <br />DS = DOOR SWITCH <br />M = MOTOR RATED SWITCH <br />OS <br />CEILING MOUNTED OCCUPANCY SENSOR <br />POWER <br />STRAIGHT BLADE DUPLEX RECEPTACLE <br />SUBSCRIPTS: <br />HG = HOSPITAL GRADE <br />HGT = HOSPITAL GRADE TAMPER RESISTANT <br />GFI = GROUND FAULT INTERRUPTER <br />SS = SURGE SUPRRESSION <br />AC = 6" ABOVE COUNTER <br />STRAIGHT BLADE DOUBLE DUPLEX RECEPT. (FOURPLEX) <br />e- <br />STRAIGHT BLADE SINGLE RECEPTACLE <br />STRAIGHT BLADE DUPLEX RECEPT. HALF -SWITCHED <br />STRAIGHT BLADE DUPLEX RECEPT. ON EMERGENCY CIRCUIT <br />® <br />OUTLET WITH SPECIAL DEVICE, AS NOTED <br />WALL MOUNTED OUTLET WITH SPECIAL DEVICE, AS <br />NOTED <br />® <br />FLOOR MOUNTED QUAD RECEPTACLE, AS NOTED <br />® <br />FLOOR MOUNTED DUPLEX RECEPTACLE, AS NOTED <br />PEI <br />FLOOR MOUNTED COMBINATION OUTLET BOX, AS <br />NOTED <br />® <br />STRAIGHT BLADE DUPLEX RECEPTACLE, CEILING <br />OO <br />POKE THROUGH, AS NOTED <br />O <br />PEDESTAL OUTLET, AS NOTED <br />❑J <br />JUNCTION BOX AS NOTED <br />( <br />OUTLET BOX <br />( H <br />WALL MOUNTED OUTLET BOX <br />�D <br />ABOVE CEILING POWER DISTRIBUTION BOX <br />SURFACE RACEWAY, AS NOTED <br />TELE-POWER POLE <br />PB <br />PULL BOX <br />OM <br />CONNECTION TO MOTOR <br />® <br />MAGNETIC MOTOR STARTER <br />SUBSCRIPTS: <br />MS = MULTISPEED <br />SSRV = SOLID-STATE, REDUCED VOLTAGE <br />VF = VARIABLE FREQUENCY <br />OT <br />WALL MOUNTED OUTLET BOX FOR THERMOSTAT <br />NOTE: ALL SYMBOLS SHOWN ON LEGEND <br />ARE NOT NECESSARILY USED. <br />LS <br />SAFETY DISCONNECT SWITCH (NON -FUSED) <br />FIRE ALARM SYSTEM <br />FUSED DISCONNECT SWITCH, 30/3/l/NF INDICATES <br />FACP <br />FIRE ALARM CONTROL PANEL <br />30AMP FRAME, 3-POLE, NEMA 1, NON -FUSED <br />FAGP <br />N <br />COMBINATION DISCONNECT AND STARTER <br />0 <br />FIRE ALARM GRAPHIC PANEL <br />ENCLOSED CIRCUIT BREAKER, MOLDED -CASE, <br />FAAP <br />FIRE ALARM ANNUNCIATOR PANEL <br />THERMAL -MAGNETIC <br />Q <br />MANUAL PULL STATION <br />SUBSCRIPTS: <br />FIRE ALARM STROBE <br />AT = ADJUSTABLE TRIP <br />�� <br />ED< <br />GENERAL ALARM COMBINATION HORN/STROBE <br />EAT = ELECTRONIC ADJUSTABLE TRIP <br />l< <br />FIRE ALARM HORN <br />CL = CURRENT LIMITING <br />CEILING OR WALL MOUNTED DETECTOR <br />IF = INTEGRALLY FUSED <br />SUBSCRIPTS: <br />GFCI = GROUND FAULT CIRCUIT INTERRUPTER <br />I = IONIZATION <br />ST = SHUNT TRIP <br />T = THERMAL, FIXED AND RATE -OF -RISE <br />KI = KEY INTERLOCK <br />TF = THERMAL, FIXED <br />ZSI = ZONE -SELECTIVE INTERLOCKING <br />T165° =165`F THERMAL, FIXED AND RATE -OF -RISE <br />CONNECTION TO PRE -WIRED EQUIPMENT <br />TF165° =165°F THERMAL, FIXED <br />0 <br />BREAKER PANEL <br />P = PHOTOELECTRIC <br />MCC <br />MOTOR CONTROL CENTER <br />PT = COMBINATION PHOTOELECTRIC AND THERMAL <br />F­SS_1 <br />TRANSIENT VOLTAGE SURGE SUPPRESSOR <br />S = SMOKE <br />IDTRANSFORMER <br />OD <br />SMOKE DETECTOR IN VENTILATING DUCT <br />Rd <br />ENGINE GENERATOR <br />A <br />FAN SHUT -DOWN CONNECTION <br />Q <br />MAG. DOOR HOLDER <br />TC <br />TIME CLOCK <br />(Z> <br />SPRINKLER SYSTEM FLOW SWITCH <br />C1 <br />LIGHTING CONTACTOR; NUMERAL INDICATES CONTACTOR NUMBER. <br />SPRINKLER SYSTEM TAMPER SWITCH <br />OFIREFIGHTERS <br />TELEPHONE JACK <br />CIRCUITING <br />© F <br />LIFE SAFETY SPEAKER <br />CONDUIT RUN <br />ED< <br />LIFE SAFETY SPEAKER WITH STROBE <br />CIRCUIT HOMERUN TO PANEL OR CABINET, NO. <br />p O-I <br />REMOTE PILOT LIGHT <br />OF ARROWS INDICATE NO. OF CIRCUITS. <br />WHERE SHOWN, HASH MARKS DENOTE THE <br />P�O-I <br />REMOTE PILOT LIGHT WITH TEST SWITCH <br />FOLLOWING: '%" = HOT; 'r" = NEUTRAL; <br />GROUND <br />MONITOR MODULE <br />--0 <br />CIRCUIT TURNED UP <br />� <br />CONTROL MODULE <br />CIRCUIT TURNED DOWN <br />® <br />DAMPER CONNECTION <br />— 3 <br />CONDUIT STUB -OUT - CAP & MARK <br />CIRCUIT IN FLEXIBLE CONDUIT <br />COMMUNICATION SYSTEM <br />SEALOFF <br />In <br />FLOOR MOUNTED TELEPHONE AND/OR DATA <br />- _ _ _ _ _ - <br />CONDUIT BELOW FLOOR <br />OUTLET BOX, AS NOTED <br />- <br />SWITCHED POWER CIRCUIT. SEE <br />WALL MOUNTED TELEPHONE OUTLET <br />NOTE 14 ON SHEET E200. <br />0 <br />WALL MOUNTED DATA OUTLET <br />0 <br />WALL MOUNTED COMBINATION <br />SCHEMATIC WIRING GRAPHICS <br />TELEPHONE/DATA OUTLET BOX <br />METER <br />W <br />WALL MOUNTED AT 48" WITH MOUNTING BRACKET <br />GROUND CONNECTION AS NOTED <br />—� <br />FUSED DISCONNECT SWITCH <br />Q QS -I CEILING OR WALL MOUNTED SPEAKER <br />-1 lvr <br />FUSES <br />a <br />VOLUME CONTROL <br />d � <br />MAGNETIC MOTOR STARTER <br />O V <br />FLOOR OR WALL MOUNTED MICROPHONE OUTLET <br />SUBSCRIPTS: <br />C <br />CALL -IN SWITCH <br />MS = MULTISPEED <br />S J <br />TIME -TONE UNIT <br />SSRV = SOLID-STATE, REDUCED VOLTAGE <br />JQ CEILING OR WALL MOUNTED CLOCK <br />VF = VARIABLE FREQUENCY <br />©-I <br />DOOR BELUCHIME <br />ENCLOSED CIRCUIT BREAKER, MOLDED -CASE, <br />© <br />BUZZER <br />THERMAL -MAGNETIC <br />O <br />HOUSE PHONE/INTERCOM <br />SUBSCRIPTS: <br />OI <br />MASTER INTERCOM STATION <br />AT = ADJUSTABLE TRIP <br />TV <br />TELEVISION ANTENNA OUTLET <br />EAT = ELECTRONIC ADJUSTABLE TRIP <br />CC <br />CLOSED CIRCUIT TV OUTLET <br />CL =CURRENT LIMITING <br />Cad <br />COAX OUTLET <br />IF = INTEGRALLY FUSED <br />AMPLIFIER <br />GFCI = GROUND FAULT CIRCUIT INTERRUPTER <br />V <br />ST = SHUNT TRIP <br />a <br />TEMPERATURE SENSOR <br />KI = KEY INTERLOCK <br />ZSI = ZONE -SELECTIVE INTERLOCKING <br />POWER TRANSFORMER <br />NOTATIONS <br />- <br />CURRENT TRANSFORMER <br />1- <br />UPPER CASE LETTER AT LUMINAIRES (F1,11, ETC.) <br />Q <br />AMMETER <br />INDICATES LUMINAIRE TYPE. LUMINAIRES IN AREA <br />OV <br />INDICATED. WHERE NOTED, NUMBER ADJACENT TO <br />VOLT METER <br />LUMINAIRE TYPE INDICATES CIRCUIT NUMBER FOR <br />THAT LUMINAIRE (E.G., F1/27) <br />TRANSFER SWITCH. <br />GF <br />2- <br />LOWER CASE LETTER AT LUMINAIRES AND SWITCHES <br />GROUND FAULT PROTECTION <br />(a, b, ETC.) INDICATE ASSOCIATED UNITS FOR <br />G <br />GENERATOR <br />3- <br />SWITCHING. <br />DIAGONAL WITHIN LUMINAIRE DENOTES UNIT ON <br />EMERGENCY (EM) CIRCUIT WITH BATTERY. <br />3 <br />MOTOR, NUMBER INDICATES HORSEPOWER <br />4- <br />"NL" WITHIN LUMINAIRES DENOTES UNIT ON NIGHT <br />LIGHT CIRCUIT. <br />PP <br />LIGHTING CONTROL POWER PACK <br />5- <br />PLUS (+) SIGN WITH DIMENSION AT OUTLET <br />-I <br />CONTACTOR <br />INDICATES HEIGHT ABOVE FINISHED FLOOR OR <br />GRADE TO CENTERLINE OF OUTLET. <br />ABBREVIATIONS <br />NOTE: ALL ABBREVIATIONS SHOWN ON <br />LEGEND ARE NOT NECESSARILY USED. <br />AC <br />- ABOVE COUNTER <br />AFC <br />- ABOVE FINISHED CEILING <br />AFF <br />-ABOVE FINISHED FLOOR <br />AFG <br />-ABOVE FINISHED GRADE <br />AIC <br />-AMPS INTERRUPTING CURRENT <br />AL <br />-ALUMINUM <br />BFG <br />- BELOW FINISHED GRADE <br />CB <br />- CIRCUIT BREAKER <br />CR <br />- CORROSION RESISTANT <br />CT <br />- CURRENT TRANSFORMER <br />CU <br />-COPPER <br />DISC <br />- DISCONNECT <br />EM <br />-EMERGENCY <br />ES <br />- EMERGENCY STOP <br />EWC <br />- ELECTRIC WATER COOLER <br />EX <br />- EXISTING <br />FLA <br />- FULL LOAD AMPS <br />FVNR <br />- FULL VOLTAGE, NON -REVERSING <br />FVR <br />- FULL VOLTAGE, REVERSING <br />FWE <br />- FURNISHED WITH EQUIPMENT <br />GFI <br />- GROUND FAULT INTERRUPTER <br />GRC <br />- GALVANIZED RIGID CONDUIT <br />HOA <br />- HAND -OFF -AUTOMATIC <br />HP <br />-HORSEPOWER <br />IG <br />-ISOLATED GROUND <br />LC <br />- LIGHTING CONTACTOR <br />MCA <br />- MINIMUM CIRCUIT AMPS <br />MCB <br />- MAIN CIRCUIT BREAKER <br />MCC <br />- MOTOR CONTROL CENTER <br />MCP <br />- MOTOR CIRCUIT PROTECTION <br />MLO <br />- MAIN LUGS ONLY <br />NC <br />- NORMALLY CLOSED <br />NIC <br />- NOT IN CONTRACT <br />NL <br />- NIGHT LIGHT <br />NO <br />- NORMALLY OPEN <br />NTS <br />- NOT TO SCALE <br />OC <br />- OVER CURRENT <br />OL <br />-OVERLOAD <br />PART <br />- PARTIAL CIRCUIT <br />POS <br />- POINT OF SALES <br />TTB <br />- TELEPHONE TERMINAL BOARD <br />UG <br />-UNDERGROUND <br />WG <br />- WIREGUARD <br />WP <br />-WEATHERPROOF <br />WSHP <br />- WATER SOURCE HEAT PUMP <br />XFMR <br />-TRANSFORMER <br />THESE DRAWINGS ARE DIAGRAMMATIC - <br />REFER TO ARCHITECTURAL DRAWINGS FOR <br />EXACT DIMENSIONS. BRANCH CIRCUITING <br />CONVENTION - #12 AWG PER PHASE AND <br />NEUTRAL (WHERE REQUIRED) AND 20 AMPERE <br />CIRCUIT BREAKER, UNLESS OTHERWISE <br />NOTED. PROVIDE QUANTITY AND SIZE <br />SWITCH CONDUCTORS AS REQUIRED TO MAKE <br />SYSTEM OPERATIONAL. <br />GENERAL NOTES (FOR ALL ELECTRICAL SHEETS) <br />1. COORDINATE LOCATION OF LUMINAIRES WITH ARCHITECTURAL REFLECTED CEILING <br />PLANS. <br />2. 3 AND 4 LAMP FIXTURES SHOWN WITH DIAGONAL SHALL HAVE INBOARD LAMP <br />CONNECTED TO EMERGENCY BATTERY PACK. SEE SPECIFICATIONS. <br />3. PROVIDE (1) 3/4"C. (MIN) WITH PULL WIRE FROM EACH TELEPHONE, DATA OR <br />COMMUNICATION OUTLET SHOWN, TO ABOVE ACCESSIBLE CEILING, AND CAP. <br />4. COORDINATE EXACT EQUIPMENT LOCATIONS WITH OWNER PRIOR TO ROUGH -INS. <br />5. COORDINATE LOCATION OF ALL OUTLETS WITH ARCHITECTURAL ELEVATIONS, <br />CASEWORK SHOP DRAWINGS AND EQUIPMENT INSTALLATION DRAWINGS. <br />6. COORDINATE LOCATION OF MECHANICAL EQUIPMENT WITH MECHANICAL PLANS <br />AND MECHANICAL CONTRACTOR PRIOR TO ROUGH -IN. <br />7. ANY ITEMS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE <br />CONTRACTOR. <br />8. ALL 120V BRANCH CIRCUITS SHALL BE 3-WIRE (PHASE, NEUTRAL, GROUND). <br />9. CONTRACTOR SHALL NOT ROUTE ANY CONDUIT WITHIN STRUCTURAL OR TOPPING <br />SLABS OF FLOORS UNLESS NOTED TO DO SO. <br />10. REFER TO ARCHITECTURAL PLANS, ELEVATIONS AND DIAGRAMS FOR LOCATIONS <br />OF FLOOR DEVICES AND WALL DEVICES. LOCATION WILL INDICATE VERTICAL AND/ <br />OR HORIZONTAL MOUNTING. IF DEVICES ARE NOT NOTED OTHERWISE THEY SHALL <br />BE MOUNTED LONG AXIS VERTICAL AT +16" TO CENTER. <br />11. INFORMATION ON THE DRAWINGS HAS BEEN ASCERTAINED FROM INFORMATION <br />PROVIDED BY OTHERS. THIS INFORMATION IS AS ACCURATE AS <br />CONDITIONS WOULD ALLOW. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO <br />VISIT THE SITE, PRIOR TO BID, AND FAMILIARIZE HIMSELF WITH THE EXTENT OF <br />REMODEL WORK REQUIRED. NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF <br />A FORESEEABLE NATURE REQUIRED TO ACHIEVE THE END RESULT AS INDICATED <br />BY CONTRACT DOCUMENTS. <br />12. ALL NEW WIRING REQUIRED BY TENANT BUILDOUT SHALL BE FISHED THROUGH <br />EXISTING WALLS OR CONCEALED IN NEW WALLS OR ABOVE CEILINGS. SURFACE <br />MOUNTED CONDUIT SHALL NOT BE USED IN ANY FINISHED AREAS. <br />13. MAINTAIN CIRCUIT CONTINUITY FOR ALL EXISTING ITEMS THAT ARE REMAINING OR <br />BEING RELOCATED. <br />14. PROVIDE UPDATED PANEL DIRECTORIES FOR ALL EXISTING PANELS BEING <br />AFFECTED BY REMODEL WORK CIRCUIT NUMBERS SHOWN MAY NOT REFLECT <br />ACTUAL FIELD CONDITIONS. PROVIDE NEW CIRCUIT BREAKER NUMBER <br />IDENTIFICATION AS REQUIRED. <br />15. ALL ITEMS SHOWN TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY <br />INCLUDING ALL ASSOCIATED CONDUIT AND WIRE BACK TO POINT OF ORIGIN OR <br />NEAREST EXISTING ITEM THAT IS REMAINING, UNLESS OTHERWISE NOTED. <br />16. WHERE EXISTING DEVICES, SWITCHES, MOTOR CONNECTIONS, ETC. ARE TO BE <br />REMOVED FROM WALLS WHICH ARE REMAINING, WALLS SHALL BE PATCHED TO <br />MATCH ORIGINAL FINISH, AFTER CONDUCTORS HAVE BEEN REMOVED. BLANK <br />COVERPLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE. <br />17. IF EXISTING CONDUITS ARE ROUTED IN CONCRETE FLOOR SLABS, CONCRETE <br />WALLS OR CONCRETE CEILINGS, THEY SHALL BE CUT BACK TO WITHIN CONCRETE <br />AND FILLED WITH GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH FLUSH WITH <br />CONCRETE SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED. <br />www.brph.com Copyright © 2014 <br />Architects, Engineers, Inc. <br />2727 Paces Ferry Road I Bldg 1 I Suite 1800 <br />Atlanta I Georgia 1 30339 <br />770-933-9242 1 770-933-9246 f <br />Offices in Melbourne, Orlando, West Palm <br />Beach, Atlanta, Charleston, Seattle <br />These plans are protected by Federal Copyright <br />protection. Unauthorized use may result in an <br />infringement action. <br />ISSUE FOR PERMIT AND CONSTRUCTION <br />REVISION <br />r <br />In <br />J <br />M <br />J <br />LL. <br />— <br />W <br />J <br />J <br />Z <br />— <br />O <br />M <br />W <br />J <br />= <br />�— <br />V <br />Qom, <br />w <br />1 <br />� <br />�w^ <br />� <br />J <br />W <br />Q <br />N011. <br />t� <br />r <br />ARCH/ENGR OF RECORD <br />JOHN D. ADDISON <br />FL PE #59239 <br />DESIGNED BY <br />JAH <br />DRAWN BY <br />JAH <br />CHECKED BY <br />JDA <br />PROJECT NUMBER <br />C06898.057.01 <br />DATE <br />08/13/14 <br />TITLE <br />ELECTRICAL <br />LEGEND <br />DRAWING NO. <br />1 <br />3 4 <br />5 <br />P <br />