ELECTRICAL PLAN NOTES THIS SHEET: <br />E y <br />y <br />I�r <br />a) <br />C <br />t <br />1 <br />v <br />0 <br />NI <br />0 <br />am <br />w <br />JI <br />LL <br />I <br />CL <br />Na) <br />I <br />O <br />LO <br />A <br />0 <br />co <br />E <br />0 <br />0 <br />o 2 <br />C <br />0 a. <br />iu <br />c co <br />a) <br />L <br />7 <br />V) <br />Q, cm <br />Z) co <br />TELCO BACKBOARD NOTES: <br />O <br />® 0 <br />GC TO INSTALL 2' LONG SHELF <br />NEAR TOP OF PLYWOOD <br />BACKBOARD FOR AT&T WI-FI AND <br />NeN• N.Ns ...N. N.N. <br />MUSIC EQUIPMENT; 1 DATA JACK TO <br />TERMINATE AT MUSIC EQUIPMENT. <br />NEW QUAD ELECTRICAL OUTLET, <br />WITH DEDICATED 20 AMP CIRCUIT <br />JUST BELOW OR NEXT TO TELCO <br />BOARD. <br />O3 3O <br />4'x4'x3/4" PLYWOOD TELCO <br />BACKBOARD, LOCATED AT TELCO <br />DEMARCATION POINT WITHIN SPACE. <br />® <br />ALL CABLING TO TERMINATE WITH <br />THE 48 PORT PATCH PANEL, TO BE <br />LOCATED WITH TELCO BOARD. <br />O5 <br />TELEPHONE SERVICE ENTRANCE <br />05 <br />CONDUIT AND CABLES ROUTE FROM <br />ABOVE OR BELOW AS REQUIRED BY <br />THE PARTICULAR INSTALLATION. <br />O <br />FINISH FLOOR <br />TELCO BACKBOARD <br />NTS <br />PROVIDE 240V, 200A, 3 <br />POLE HEAVY DUTY <br />FUSED DISCONNECT TO 4 #3/0 (CU), #6G (CU), 21/2"C <br />MATCH EXISTING <br />BUILDING EXTERIOR <br />TYPICAL OUTLET CONFIGURATION DETAILS <br />AATV (TV WALL): PROVIDE CONDUIT FROM <br />ACCESSIBLE CEILING TO COAX <br />TERMINATIONS. ROUTE COAX <br />CABLING TO MDF ROOM. <br />[� I= NIGHT LIGHT <br />o <br />(1) COAX AND (2) DATA / DUPLEX RECEPTACLE + <br />NIGHT LIGHT DUPLEX RECEPTACLE <br />BCW (BACKWRAP) AND PTR (PRINTER): <br />0 0 <br />O O O O <br />(1) SWITCHED <br />DUPLEX (1) DUPLEX RECEPTACLE FOR <br />RECEPTACLE PRINTER <br />FOR INTEGRATED (1) QUAD RECEPTACLE / (4) DATA / <br />LIGHTING (1) TELEPHONE FOR PRINTER AND <br />ADDITIONAL IT EQUIPMENT <br />1. WIRELESS ACCESS POINT. PROVIDE DATA FROM MDF BOARD WITH <br />25'-0" SERVICE LOOP FOR FINAL CONNECTION TO BE DETERMINED BY IT <br />SURVEY <br />2. REFER TO ELECTRICAL SLAB PLAN, SHEET E500, FOR CONDUIT AND <br />FLOOR BOXES SHOWN HERE IN SLAB. <br />3. SHOPPERTRAK SYSTEM. EXTEND TO MDF BACKBOARD. IN SALES AREA, <br />COORDINATE EXACT LOCATION AND CABLING REQUIREMENTS WITH <br />SHOPPERTRAK VENDOR PRIOR TO ROUGH -IN. <br />4. SHOWROOM RECEPTACLE SHALL BE FLUSH MOUNTED IN CEILING WITHIN 18" <br />OF WINDOW PER NEC 210.62. <br />5. PROVIDE LIGHTING CONTROLS IN THIS ROOM. REFER TO LIGHTING CONTROL <br />DETAIL ON SHEET E300. <br />6. NIGHT LIGHT. CONNECT NOTED DUPLEX OR NON -SWITCHED HALF OF <br />QUADRUPLEX TO UNSWITCHED CONTINUOUSLY HOT CONDUCTOR OF CIRCUIT <br />INDICATED FOR 24-HOUR OPERATION. <br />7. REFER TO OUTLET DETAILS THIS SHEET FOR AATV WALL DEVICE <br />INFORMATION. REFER TO ARCHITECTURAL ELEVATIONS FOR DEVICE <br />MOUNTING HEIGHTS AND LOCATIONS. <br />8. COORDINATE DEVICE MOUNTING LOCATIONS WITHIN CASEWORK WITH <br />ARCHITECTURAL DETAILS, AT&T, AND CASEWORK INSTALLER. <br />9. DEVICES BEHIND WALL UNITS SHALL BE LOCATED PER ARCHITECTURAL. <br />COORDINATE WITH ARCHITECTURAL PLANS PRIOR TO ROUGH -IN. <br />10. NOT USED. <br />11. UTILIZE EXISTING CONDUIT WITH PULLSTRING FROM BUILDING TELCO DEMARC <br />POINT TO AT&T TENANT SPACE; EXTEND CONDUIT AS REQUIRED TO STUB <br />OUT AT MDF BOARD. FIELD VERIFY EXACT LOCATION AND SIZE OF EXISTING <br />CONDUIT AND COORDINATE REQUIREMENTS WITH AT&T AND LOCAL PHONE <br />COMPANY. <br />12. NOT USED <br />13. EXTEND EXISTING CONDUIT FROM ROOF FOR FUTURE ROOF INSTALLED DEVICES <br />(SATELLITE DISH, MUZAK, ETC.) AS REQUIRED TO STUB OUT AT MDF BOARD. <br />FIELD VERIFY EXISTING CONDUIT LOCATION, AND COORDINATE EXACT <br />REQUIREMENTS WITH OWNER. <br />14. SWITCHED RECEPTACLE FOR DISPLAY LIGHTS. FOR QUADRUPLEX <br />RECEPTACLES, PROVIDE DUAL BRANCH CIRCUIT IN BOX WITH ONE CIRCUIT <br />PER DUPLEX RECEPTACLE SWITCHED AS NOTED VIA SWITCHBANK AND ONE <br />DUPLEX RECEPTACLE ALWAYS HOT AS INDICATED ON PLAN. DASH -DOT <br />LINETYPE DENOTES SWITCHED CIRCUIT. PROVIDE BLACK ADHESIVE LABEL <br />WITH 1/4" LETTERING NOTING "SWITCHED FOR LIGHTING" ON SWITCHED <br />DUPLEX. <br />15. MOUNT WEATHERPROOF RECEPTACLES ON ROOFTOP UNITS. <br />16. PROVIDE 20Al2P MOTOR RATED SWITCH FOR CONNECTION TO ELECTRIC WATER <br />HEATER. MOUNT SWITCH WITHIN SIGHT OF UNIT. <br />17. LIGHTING SWITCH BANK. LOWERCASE SUBSCRIPTS DENOTES SWITCH ZONE. <br />18. POWER FOR CONNECTION TO HAND DRYER. COORDINATE MOUNTING <br />LOCATION WITH ARCHITECTURAL AND OWNER PRIOR TO ROUGH -IN. <br />19. INDOOR UNIT AC-1 IS POWERED FROM ROOFTOP UNIT CU-1. PROVIDE WIRING AND <br />CONDUIT FROM ROOFTOP UNIT TO INDOOR UNIT AS REQUIRED. FIELD COORDINATE <br />WITH MECHANICAL CONTRACTOR. <br />20. APPROXIMATE LOCATION OF EXISTING POWER AND TELCO EMPTY CONDUIT <br />STUB -UPS. EXTEND NEW 2" CONDUIT TO PANEL A AND 1" TO BACKBOARD <br />LOCATION. <br />POWER SHEET NOTES: <br />A. PROVIDE PULL STRING IN ALL EMPTY CONDUIT. <br />B. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF ALL POWER <br />AND DATA OUTLETS. <br />C. REFER TO AT&T STANDARDS FOR FLOORBOX SPECIFICATION. <br />D. EXISTING METERING AND FEEDERS TO TENANT SPACE PANELBOARD <br />ARE INTENDED TO REMAIN AS INSTALLED. CONTRACTOR SHALL FIELD <br />VERIFY THAT EXISTING FEEDERS AND METERING IS IN GOOD WORKING <br />CONDITION. IF NOT, REPLACE WITH EQUIVALENT NEW PRODUCT. <br />E. PROVIDE ALL WIRING IN FULL COMPLIANCE WITH MOST CURRENT AT&T <br />STANDARDS AS ALLOWED BY LOCAL CODES AND ORDINANCES. <br />F. EXHAUST FAN EF-1 SHALL BE SWITCHED WITH LOCAL LIGHTING. <br />NEW PANEL W. <br />4 #3/0 (CU), #6G (CU), 21/2"C <br />TIE INTO EXISTING (TYPICAL). <br />TENANT SPACE <br />EXISTING (2) 21/2" EMPTY CONDUIT <br />EXTEND ONE TO NEW DISCONNECT <br />AND PANEL AS REQUIRED. <br />1 <br />O <br />o <br />0 <br />0 <br />(2) DATA FOR DIGITAL <br />LIFE & EVERY OTHER <br />MWU <br />NON - <br />SWITCHED <br />IP (I -PHONE): <br />o .o <br />O <br />DUPLEX RECEPTACLE / (2) DATA <br />SWITCHED FOR I <br />DISPLAY LIGHTING <br />www.brph.com Copyright © 2014 <br />Architects, Engineers, Inc. <br />2727 Paces Ferry Road I Bldg 1 1 Suite 1800 <br />Atlanta I Georgia 1 30339 <br />770-933-9242 1 770-933-9246 f <br />Offices in Melbourne, Orlando, West Palm <br />Beach, Atlanta, Charleston, Seattle <br />These plans are protected by Federal Copyright <br />protection. Unauthorized use may result in an <br />infringement action. <br />ISSUE FOR PERMIT AND CONSTRUCTION <br />REVISION 0 <br />r <br />IV <br />In <br />M <br />J <br />ch <br />— <br />J <br />Q <br />LL. <br />J <br />W <br />� <br />J <br />Z <br />J <br />ONN. <br />N! <br />N <br />G <br />Z <br />o <br />W <br />06 <br />>_ <br />J <br />U) <br />L.L. <br />J <br />W <br />Q <br />N <br />c� <br />0 <br />ARCH/ENGR OF RECORD <br />JOHN D. ADDISON <br />FL PE #59239 <br />DESIGNED BY <br />JAH <br />DRAWN BY <br />JAH <br />CHECKED BY <br />JDA <br />PROJECT NUMBER <br />C06898.057.01 <br />DATE <br />08/13/14 <br />TITLE <br />DRAV41NG NO. <br />E200 <br />U 06 <br />1 <br />2 <br />3 <br />rd <br />w <br />ill <br />