<br />EXISTING TO REMAIN
<br />LIGHTING�PLAND 2' 4' 8' 12'
<br />1
<br />LIGHTING FIXTURE SCHEDULE
<br />FIXTURE TYPE
<br />MANUFACTURER
<br />CATALOG NUMBER
<br />LAMPS
<br />DESCRIPTION
<br />Voltage
<br />F4A
<br />COOPER HALO
<br />L50516-20CMH-P-L111-LM5051
<br />(1) 20W CMH
<br />CANOPY MOUNTED CMH MR16 MONOPOINT ACCENT
<br />120 V
<br />STATIS
<br />6-L973-AH CANOPY
<br />LIGHT, LOCKING TILT AND ROTATION, ON -OFF SWITCH,
<br />ALUMINIM DIE-CAST HOUSING WITH VERTICAL
<br />ELECTRONIC BALLAST, SOFT FOCUS LENS AND HOLDER,
<br />SQUARE MONOPOINT CANOPY ACCESSORY, ALUMINUM
<br />HAZE FINISH.
<br />F12
<br />LITE ENERGY /
<br />LE/CS-44120-4XF25T8-120
<br />(4) F25/T8 SPX35/ECO
<br />48" DIAMETER LARGE SCALE SURFACE MOUNTED
<br />120 V
<br />LIGHTOLIER
<br />LUMINAIRE WITH WHITE ACRYLIC DIFFUSER, 20 GAUGE
<br />DIEFORMED STEEL HOUSING, ELECTRONIC BALLAST(S),
<br />POLYESTER POWDER COAT MATTE WHITE FINISH.
<br />F16
<br />COOPER
<br />METALUX
<br />(3) F32/T8 SPX35
<br />VX4' RECESSED FLUORESCENT DIRECT LIGHT, HIGH
<br />120 V
<br />GC332-UNV-EB81-U-1X4 MILK
<br />REFLECTANCE WHITE POWDER COAT PAINT FINISH,
<br />WHITE LEN FGW080
<br />TEXTURED FRONT GLAZE ACRYLIC LENS, STANDARD
<br />FLANGE DESIGN WORKS WITH MOST LAY -IN CEILINGS.
<br />F16E
<br />COOPER
<br />METALUX
<br />(3) F32/T8 SPX35
<br />SAME AS 'F16EXCEPT WITH EMERGENCY BATTERY
<br />120 V
<br />GC332-120-FB P24H-EB81-U-1 X
<br />PACK.
<br />4 MILK WHITE LENS FGW080
<br />J1
<br />LITHONIA
<br />2GT8232Al2MVOLTGEB-101S
<br />(2) F32/T8 SPX35
<br />2'X4' RECESSED/PRISMATIC 2 LAMP FLUORESCENT
<br />120 V
<br />FIXTURE.
<br />J1E
<br />LITHONIA
<br />2GT8232Al2MVOLTGEB-101S-
<br />(2) F32/T8 SPX35
<br />SAME AS TYPE'J1' EXCEPT WITH INTEGRAL 1400 LUMEN
<br />120 V
<br />EL1400
<br />EMERGENCY BATTERY PACK; PROVIDE REMOTE TEST
<br />SWITCH IF REQUIRED BY LOCAL CODE
<br />CONTRACTOR SHALL VERIFY
<br />EXISTING EMERGENCY
<br />LIGHT FIXTURES PROVIDE
<br />ADEQUATE LIGHT TO PUBLIC
<br />WAY PER NFPA 101
<br />EXISTING TO REMAIN
<br />FOR EXTERIOR
<br />SIGNAGE VIA SW "T
<br />LIGHT FIXTURE SCHEDULE NOTES:
<br />1. VERIFY AND COORDINATE WITH ARCHITECT AND LIGHTING DESIGNER ALL FIXTURE MOUNTING DETAILS AND SIZES BASED ON FIELD CONDITIONS.
<br />2. ALL FIXTURES SHALL BE UL OR ETL LISTED AND LABELED.
<br />3. VERIFY FINAL FIXTURE SELECTION AND FINISHES WITH OWNER AND ARCHITECT.
<br />4. ALL FIXTURES SHALL BE SUPPLIED WITH ALL NECESSARY FEEDS, CONNECTORS, ETC. FOR A COMPLETE INSTALLATION.
<br />5. FIXTURES SHALL BE MOUNTED WITH LAMPS AND/OR REFLECTORS ORIENTED AS INDICATED ON DRAWINGS.
<br />6. REFER TO ARCHITECTURAL DRAWINGS FOR ALL MOUNTING DIMENSIONS AND/OR DETAILS. ARCHITECTURAL DRAWINGS SUPERSEDE ALL OTHERS.
<br />7. SUBMITTALS: AS PART OF THIS WORK THE CONTRACTOR SHALL, WITHIN 14 DAYS AFTER AWARD OF THE CONTRACT, SUBMIT A COMPLETE
<br />MATERIAL LIST OF ALL LIGHTING FIXTURES, LAMPS, MISCELLANEOUS MATERIALS, AND CONTROLS PROPOSED TO BE FURNISHED AND/OR INSTALLED.
<br />THIS SUBMITTAL SHALL INCLUDE MANUFACTURER'S SPECIFICATIONS, CUT -SHEETS, AND OTHER DATA REQUIRED TO DEMONSTRATE COMPLIANCE
<br />WITH THE SPECIFIED REQUIREMENTS. FURNISH THREE (3) BOUND COPIES 8-1/2" X 11".
<br />8. NO SUBSTITUTIONS OF SPECIFIED FIXTURES, LAMP, OR CONTROL MANUFACTURER WILL BE ACCEPTABLE WITHOUT SPECIFIC PRIOR WRITTEN
<br />APPROVAL OF THE ARCHITECT AND LIGHTING DESIGNER. IF CONTRACTOR OR DISTRIBUTOR MAKES A SUBSTITUTION WITHOUT SAID PRIOR
<br />APPROVAL, CONTRACTOR OR DISTRIBUTOR SHALL REPLACE THE SUBSTITUTED ITEM WITH THE SPECIFIED ITEM AND SHALL BEAR ALL ASSOCIATED
<br />COSTS (INCLUDING BUT NOT LIMITED TO THE ARCHITECTS AND/OR LIGHTING DESIGNER'S LABOR COSTS INVOLVED IN RE -AIMING FIXTURES,
<br />TRAVELING TO THE SITE, ETC.) WITHOUT ANY ADDITIONAL CHARGE TO THE OWNER.
<br />9. FINAL AIMING SHALL BE PERFORMED BY THE CONTRACTOR UNDER DIRECTION OF THE OWNER AND LIGHTING DESIGNER.
<br />10. PROVIDE ALL EXIT SIGNS REQUIRED FOR THIS PROJECT. THIS SHALL INCLUDE ALL EXIT SIGNS SHOWN ON THE PLANS AND ANY ADDITIONAL EXIT
<br />SIGNS THAT MAY BE REQUIRED BY THE LOCAL JURISDICTION. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING WITH THE JURISDICTION
<br />THE REQUIRED LENS COLOR FOR EXIT SIGNS AND THE REQUIRED QUANTITY AND LOCATIONS FOR EXIT SIGNS.
<br />11. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LIGHTING LOCATIONS.
<br />12. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE INSTALLATION OF LIGHT FIXTURES, INCLUDING BUT NOT LIMITED TO PROVIDING ALL
<br />SUPPORTS, CLIPS, POWER CONNECTIONS, AND SEISMIC BRACING AS REQUIRED BY THE LOCAL JURISDICTION.
<br />13. REMOTE HEADS SHALL BE TIED TO SEPARATE HEADLESS BATTERY PACK.
<br />GENERAL LIGHTING NOTES:
<br />A. FIXTURES DESIGNATED WITH "E" -or- "EXISTING" ARE EXISTING TO
<br />REMAIN. FIXTURES DESIGNED WITH'R' ARE EXISTING FIXTURES
<br />TO BE RELOCATED WITHIN GRID. ALL EXISTING AND RELOCATED
<br />FIXTURES SHALL BE CLEANED, RELAMPED, AND INSPECTED FOR
<br />GOOD WORKING ORDER. ANY FIXTURES NOT IN GOOD CONDITION
<br />SHALL BE REPLACED WITH SIMILAR FIXTURE.
<br />B. ALL LAMPS SHALL BE FULL -LIGHT, HIGH -EFFICIENCY ENERGY -SAVING TYPE.
<br />C. PENDANT, RECESSED, AND SURFACE MOUNTED FIXTURES SHALL BE
<br />SUPPORTED FROM THE STRUCTURE, NOT FROM CEILING GRID.
<br />D. CONTACT GRAINGER FOR ALL LIGHT FIXTURE ORDERS, SEE BELOW FOR
<br />CONTACT INFORMATION: ANDREW DODSON GRAINGER (404) 806-8263
<br />E. REFER TO SHEET E300 FOR LIGHTING FIXTURE SCHEDULE.
<br />F. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT
<br />LIGHTING FIXTURE LOCATIONS.
<br />LIGHTING NOTES THIS SHEET:
<br />1. CIRCUIT EMERGENCY LIGHTING BATTERY PACKS AND EXIT SIGNS AHEAD OF
<br />LOCAL SWITCHING FOR CONTINUOUS OPERATION. PROVIDE SEPARATE
<br />UNSWITCHED CONDUCTOR. ALL EMERGENCY LIGHTS AND EXIT SIGNS SHALL BE
<br />CIRCUITED WITH LOCAL LIGHTING CIRCUITS IN SAME AREA PER NEC.
<br />2. NIGHT LIGHT. CIRCUIT FIXTURES SHOWN AHEAD OF LIGHTING CONTROLS FOR
<br />CONTINUOUS OPERATION.
<br />3. EXHAUST FANS SWITCHED WITH LIGHTS.
<br />4. MATCH EXISTING EXIT SIGN FOR BRAND, MODEL, VOLTAGE, COLOR OF FACES, ETC,
<br />5. LIGHTING SWITCH BANK. LOWERCASE SUBSCRIPT DENOTES SWITCH ZONE.
<br />www.brph.corn Copyright © 2014
<br />Architects, Engineers, Inc.
<br />2727 Paces Ferry Road I Bldg 1 1 Suite 1800
<br />Atlanta I Georgia 1 30339
<br />770-933-9242 1 770-933-9246 f
<br />Offices in Melbourne, Orlando, West Palm
<br />Beach, Atlanta, Charleston, Seattle
<br />These plans are protected by Federal Copyright
<br />protection. Unauthorized use may result in an
<br />infringement action.
<br />ISSUE FOR PERMIT AND CONSTRUCTION
<br />REVISION Z�,
<br />7
<br />J
<br />L
<br />0
<br />U)
<br />J
<br />J
<br />■■
<br />TF
<br />7
<br />ARCH/ENGR OF RECORD
<br />JOHN D. ADDISON
<br />FL PE #59239
<br />DESIGNED BY
<br />JAH
<br />DRAWN BY
<br />JAH
<br />CHECKED BY
<br />JDA
<br />PROJECT NUMBER
<br />C06898.057.01
<br />DATE
<br />08/13/14
<br />TITLE
<br />LIGHTING
<br />DRAWING NO.
<br />C�Ic�iI�7