Laserfiche WebLink
E <br />C <br />f� <br />LO <br />A <br />o <br />rn <br />co <br />co <br />a) <br />E <br />U <br />0 <br />o <br />0o rL <br />co <br />(D <br />c C0 <br />a) d <br />c <br />w <br />a)0 <br />M) m <br />EXISTING TO REMAIN <br />LIGHTING�PLAND 2' 4' 8' 12' <br />1 <br />LIGHTING FIXTURE SCHEDULE <br />FIXTURE TYPE <br />MANUFACTURER <br />CATALOG NUMBER <br />LAMPS <br />DESCRIPTION <br />Voltage <br />F4A <br />COOPER HALO <br />L50516-20CMH-P-L111-LM5051 <br />(1) 20W CMH <br />CANOPY MOUNTED CMH MR16 MONOPOINT ACCENT <br />120 V <br />STATIS <br />6-L973-AH CANOPY <br />LIGHT, LOCKING TILT AND ROTATION, ON -OFF SWITCH, <br />ALUMINIM DIE-CAST HOUSING WITH VERTICAL <br />ELECTRONIC BALLAST, SOFT FOCUS LENS AND HOLDER, <br />SQUARE MONOPOINT CANOPY ACCESSORY, ALUMINUM <br />HAZE FINISH. <br />F12 <br />LITE ENERGY / <br />LE/CS-44120-4XF25T8-120 <br />(4) F25/T8 SPX35/ECO <br />48" DIAMETER LARGE SCALE SURFACE MOUNTED <br />120 V <br />LIGHTOLIER <br />LUMINAIRE WITH WHITE ACRYLIC DIFFUSER, 20 GAUGE <br />DIEFORMED STEEL HOUSING, ELECTRONIC BALLAST(S), <br />POLYESTER POWDER COAT MATTE WHITE FINISH. <br />F16 <br />COOPER <br />METALUX <br />(3) F32/T8 SPX35 <br />VX4' RECESSED FLUORESCENT DIRECT LIGHT, HIGH <br />120 V <br />GC332-UNV-EB81-U-1X4 MILK <br />REFLECTANCE WHITE POWDER COAT PAINT FINISH, <br />WHITE LEN FGW080 <br />TEXTURED FRONT GLAZE ACRYLIC LENS, STANDARD <br />FLANGE DESIGN WORKS WITH MOST LAY -IN CEILINGS. <br />F16E <br />COOPER <br />METALUX <br />(3) F32/T8 SPX35 <br />SAME AS 'F16EXCEPT WITH EMERGENCY BATTERY <br />120 V <br />GC332-120-FB P24H-EB81-U-1 X <br />PACK. <br />4 MILK WHITE LENS FGW080 <br />J1 <br />LITHONIA <br />2GT8232Al2MVOLTGEB-101S <br />(2) F32/T8 SPX35 <br />2'X4' RECESSED/PRISMATIC 2 LAMP FLUORESCENT <br />120 V <br />FIXTURE. <br />J1E <br />LITHONIA <br />2GT8232Al2MVOLTGEB-101S- <br />(2) F32/T8 SPX35 <br />SAME AS TYPE'J1' EXCEPT WITH INTEGRAL 1400 LUMEN <br />120 V <br />EL1400 <br />EMERGENCY BATTERY PACK; PROVIDE REMOTE TEST <br />SWITCH IF REQUIRED BY LOCAL CODE <br />CONTRACTOR SHALL VERIFY <br />EXISTING EMERGENCY <br />LIGHT FIXTURES PROVIDE <br />ADEQUATE LIGHT TO PUBLIC <br />WAY PER NFPA 101 <br />EXISTING TO REMAIN <br />FOR EXTERIOR <br />SIGNAGE VIA SW "T <br />LIGHT FIXTURE SCHEDULE NOTES: <br />1. VERIFY AND COORDINATE WITH ARCHITECT AND LIGHTING DESIGNER ALL FIXTURE MOUNTING DETAILS AND SIZES BASED ON FIELD CONDITIONS. <br />2. ALL FIXTURES SHALL BE UL OR ETL LISTED AND LABELED. <br />3. VERIFY FINAL FIXTURE SELECTION AND FINISHES WITH OWNER AND ARCHITECT. <br />4. ALL FIXTURES SHALL BE SUPPLIED WITH ALL NECESSARY FEEDS, CONNECTORS, ETC. FOR A COMPLETE INSTALLATION. <br />5. FIXTURES SHALL BE MOUNTED WITH LAMPS AND/OR REFLECTORS ORIENTED AS INDICATED ON DRAWINGS. <br />6. REFER TO ARCHITECTURAL DRAWINGS FOR ALL MOUNTING DIMENSIONS AND/OR DETAILS. ARCHITECTURAL DRAWINGS SUPERSEDE ALL OTHERS. <br />7. SUBMITTALS: AS PART OF THIS WORK THE CONTRACTOR SHALL, WITHIN 14 DAYS AFTER AWARD OF THE CONTRACT, SUBMIT A COMPLETE <br />MATERIAL LIST OF ALL LIGHTING FIXTURES, LAMPS, MISCELLANEOUS MATERIALS, AND CONTROLS PROPOSED TO BE FURNISHED AND/OR INSTALLED. <br />THIS SUBMITTAL SHALL INCLUDE MANUFACTURER'S SPECIFICATIONS, CUT -SHEETS, AND OTHER DATA REQUIRED TO DEMONSTRATE COMPLIANCE <br />WITH THE SPECIFIED REQUIREMENTS. FURNISH THREE (3) BOUND COPIES 8-1/2" X 11". <br />8. NO SUBSTITUTIONS OF SPECIFIED FIXTURES, LAMP, OR CONTROL MANUFACTURER WILL BE ACCEPTABLE WITHOUT SPECIFIC PRIOR WRITTEN <br />APPROVAL OF THE ARCHITECT AND LIGHTING DESIGNER. IF CONTRACTOR OR DISTRIBUTOR MAKES A SUBSTITUTION WITHOUT SAID PRIOR <br />APPROVAL, CONTRACTOR OR DISTRIBUTOR SHALL REPLACE THE SUBSTITUTED ITEM WITH THE SPECIFIED ITEM AND SHALL BEAR ALL ASSOCIATED <br />COSTS (INCLUDING BUT NOT LIMITED TO THE ARCHITECTS AND/OR LIGHTING DESIGNER'S LABOR COSTS INVOLVED IN RE -AIMING FIXTURES, <br />TRAVELING TO THE SITE, ETC.) WITHOUT ANY ADDITIONAL CHARGE TO THE OWNER. <br />9. FINAL AIMING SHALL BE PERFORMED BY THE CONTRACTOR UNDER DIRECTION OF THE OWNER AND LIGHTING DESIGNER. <br />10. PROVIDE ALL EXIT SIGNS REQUIRED FOR THIS PROJECT. THIS SHALL INCLUDE ALL EXIT SIGNS SHOWN ON THE PLANS AND ANY ADDITIONAL EXIT <br />SIGNS THAT MAY BE REQUIRED BY THE LOCAL JURISDICTION. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING WITH THE JURISDICTION <br />THE REQUIRED LENS COLOR FOR EXIT SIGNS AND THE REQUIRED QUANTITY AND LOCATIONS FOR EXIT SIGNS. <br />11. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LIGHTING LOCATIONS. <br />12. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE INSTALLATION OF LIGHT FIXTURES, INCLUDING BUT NOT LIMITED TO PROVIDING ALL <br />SUPPORTS, CLIPS, POWER CONNECTIONS, AND SEISMIC BRACING AS REQUIRED BY THE LOCAL JURISDICTION. <br />13. REMOTE HEADS SHALL BE TIED TO SEPARATE HEADLESS BATTERY PACK. <br />GENERAL LIGHTING NOTES: <br />A. FIXTURES DESIGNATED WITH "E" -or- "EXISTING" ARE EXISTING TO <br />REMAIN. FIXTURES DESIGNED WITH'R' ARE EXISTING FIXTURES <br />TO BE RELOCATED WITHIN GRID. ALL EXISTING AND RELOCATED <br />FIXTURES SHALL BE CLEANED, RELAMPED, AND INSPECTED FOR <br />GOOD WORKING ORDER. ANY FIXTURES NOT IN GOOD CONDITION <br />SHALL BE REPLACED WITH SIMILAR FIXTURE. <br />B. ALL LAMPS SHALL BE FULL -LIGHT, HIGH -EFFICIENCY ENERGY -SAVING TYPE. <br />C. PENDANT, RECESSED, AND SURFACE MOUNTED FIXTURES SHALL BE <br />SUPPORTED FROM THE STRUCTURE, NOT FROM CEILING GRID. <br />D. CONTACT GRAINGER FOR ALL LIGHT FIXTURE ORDERS, SEE BELOW FOR <br />CONTACT INFORMATION: ANDREW DODSON GRAINGER (404) 806-8263 <br />E. REFER TO SHEET E300 FOR LIGHTING FIXTURE SCHEDULE. <br />F. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT <br />LIGHTING FIXTURE LOCATIONS. <br />LIGHTING NOTES THIS SHEET: <br />1. CIRCUIT EMERGENCY LIGHTING BATTERY PACKS AND EXIT SIGNS AHEAD OF <br />LOCAL SWITCHING FOR CONTINUOUS OPERATION. PROVIDE SEPARATE <br />UNSWITCHED CONDUCTOR. ALL EMERGENCY LIGHTS AND EXIT SIGNS SHALL BE <br />CIRCUITED WITH LOCAL LIGHTING CIRCUITS IN SAME AREA PER NEC. <br />2. NIGHT LIGHT. CIRCUIT FIXTURES SHOWN AHEAD OF LIGHTING CONTROLS FOR <br />CONTINUOUS OPERATION. <br />3. EXHAUST FANS SWITCHED WITH LIGHTS. <br />4. MATCH EXISTING EXIT SIGN FOR BRAND, MODEL, VOLTAGE, COLOR OF FACES, ETC, <br />5. LIGHTING SWITCH BANK. LOWERCASE SUBSCRIPT DENOTES SWITCH ZONE. <br />www.brph.corn Copyright © 2014 <br />Architects, Engineers, Inc. <br />2727 Paces Ferry Road I Bldg 1 1 Suite 1800 <br />Atlanta I Georgia 1 30339 <br />770-933-9242 1 770-933-9246 f <br />Offices in Melbourne, Orlando, West Palm <br />Beach, Atlanta, Charleston, Seattle <br />These plans are protected by Federal Copyright <br />protection. Unauthorized use may result in an <br />infringement action. <br />ISSUE FOR PERMIT AND CONSTRUCTION <br />REVISION Z�, <br />7 <br />J <br />L <br />0 <br />U) <br />J <br />J <br />■■ <br />TF <br />7 <br />ARCH/ENGR OF RECORD <br />JOHN D. ADDISON <br />FL PE #59239 <br />DESIGNED BY <br />JAH <br />DRAWN BY <br />JAH <br />CHECKED BY <br />JDA <br />PROJECT NUMBER <br />C06898.057.01 <br />DATE <br />08/13/14 <br />TITLE <br />LIGHTING <br />DRAWING NO. <br />C�Ic�iI�7 <br />Z <br />O <br />V <br />W <br />ry <br />w <br />U) <br />PLAN <br />6 U 00 <br />1 <br />N <br />3 <br />4 I 5 <br />Cl <br />