ELECTRICAL SYMBOL LEGEND <br />20A, 120V, SINGLE POLE LIGHT SWITCH. MOUNT CENTER AT 48" AFF. <br />$3 20A, 120V, THREE—WAY SWITCH. MOUNT CENTER AT 48" AFF. <br />$4 20A, 120V, FOUR—WAY SWITCH. MOUNT CENTER AT 48" AFF <br />SINGLE POLE MOTOR RATED SWITCH. MOUNT ADJACENT TO EQUIPMENT TO BE <br />CONTROLLED. VERIFY AMPACITY WITH EQUIPMENT NAMEPLATE. <br />20A, 120V, SINGLE DEDICATED RECEPTACLE. MOUNT AT 18" AFF. <br />6 20A, 120V, DUPLEX RECEPTACLE. WALL MOUNT CENTER AT 18" AFF. <br />20A, 120V, DUPLEX RECEPTACLE. WALL MOUNT CENTER AT 4" ABOVE <br />COUNTER, COORDINATE WITH MILLWORK. <br />20A, 120V, GFI, DUPLEX RECEPTACLE. WALL MOUNT CENTER AT 18" AFF. <br />4 20A, 120V, GFI, DUPLEX RECEPTACLE. WALL MOUNT CENTER AT 4" ABOVE <br />COUNTER BACKSPLASH, COORDINATE WITH MILLWORK. <br />6 20A ,120V, HALF SWITCH DUPLEX RECEPTACLE. WALL MOUNT CENTER AT <br />18" AFF. <br />6 20A, 120V, DUPLEX RECEPTACLE FOR MICROWAVE. MOUNT CENTER AT 72" AFF. <br />20A, 120V, DUPLEX RECEPTACLE. RECESS FLOOR MOUNTED. PROVIDE BRASS <br />COVER PLATE AND CARPET FLANGE. <br />O 20A, 120V, DUPLEX RECEPTACLE. CEILING MOUNTED. <br />I& 20A, 120V, QUADDRUPLEX RECEPTACLE. MOUNT CENTER AT 18" AFF. <br />Fol 20A, 120V, QUADDRUPLEX RECEPTACLE. RECESS FLOOR MOUNTED. PROVIDE <br />BRASS COVER PLATE AND CARPET FLANGE. <br />® SPECIAL PUPOSE RECEPTACLE. VERIFY EXACT TYPE WITH CONTRACTOR/ <br />EQUIPMENT NAMEPLATE. <br />JB JUNCTION BOX <br />0 TELEPHONE OUTLET. WALL MOUNT AT 18" AFF. PROVIDE 3/4" CONDUIT WITH <br />PULLSTRING TO 6" ABOVE CEILING. USE 1" CONDUIT FOR THOSE DENOTED <br />WITH A "2". <br />$ TELEPHONE OUTLET. WALL MOUNT CENTER AT 4" ABOVE COUNTER, COORDINATE <br />WITH MILLWORK. PROVIDE 3/4" CONDUIT WITH PROVIDE 3/4" CONDUIT WITH <br />PULLSTRING TO 6" ABOVE CEILING. USE 1" CONDUIT FOR THOSE DENOTED <br />WITH A "2". <br />♦ DATA OUTLET. WALL MOUNT AT 18" AFF. PROVIDE 3/4" CONDUIT WITH <br />PULLSTRING TO 6" ABOVE CEILING. USE 1" CONDUIT FOR THOSE DENOTED <br />WITH A "2". <br />v TELEPHONE/bATA OUTLET. WALL MOUNT AT 18" AFF. PROVIDE 3/4" CONDUIT <br />WITH PULLSTRING TO 6" ABOVE CEILING. USE 1" CONDUIT FOR THOSE DENOTED <br />WITH A "2". <br />FV TELEPHONE OUTLET. RECESS FLOOR MOUNTED. PROVIDE 3/4" CONDUIT WITH <br />PULLSTRING TO NEAREST WALL AND THEN 6" ABOVE CEILING. USE 1" CONDUIT <br />FOR THOSE DENOTED WITH A "2". <br />Flyfl TELEPHONE/DATA OUTLET. RECESS FLOOR MOUNTED. PROVIDE 3/4" CONDUIT <br />WITH PULLSTRING TO NEAREST WALL AND THEN 6" ABOVE CEILING. USE 1" <br />CONDUIT FOR THOSE DENOTED WITH A "20 <br />. <br />0 DATA OUTLET. RECESS FLOOR MOUNTED. PROVIDE 3/4" CONDUIT WITH <br />PULLSTRING TO NEAREST WALL AND THEN 6" ABOVE CEILING. USE 1" CONDUIT <br />FOR THOSE DENOTED WITH A "2". <br />0 TELEVISION OUTLET. <br />o ELECTRICAL PANEL <br />® TRANFORMER <br />-19L 3PE:? DISCONNECT SAFETY SWITCH (3) POLES, 30A FRAME "**" DENOTES CONTRACTOR <br />TO PROVIDE FUSES PER MANUFACTURER'S NAMEPLATE, UNLESS NOTED <br />OTHERWISE. "NF" DENOTES NOT FUSED. <br />® FACTORY MOUNTED DISCONNECT. <br />C I CLOCK/INTERCOM SYSTEM <br />0 EPO EMERGENCY POWER OFF SWITCH <br />WP WEATHER PROOF <br />GFI GROUND FAULT CIRCUIT INTERRUPTER <br />AFF ABOVE FINISHED FLOOR <br />AFG ABOVE FINISHED GRADE <br />® ONE WAY EXIT SIGN BATTERY BACKUP — WIRE AHEAD OF LIGHTS <br />0 KNOX BOX. <br />02 . SMOKE DETECTOR. <br />HEAT DETECTOR. <br />BATTERY BACKUP EMERGENCY LIGHT — WIRE AHEAD OF LIGHTS <br />I os': <br />WEIGHTS <br />000 <br />105 <br />F4 I Bt <br />C2 I W1 <br />a <br />W <br />a <br />Z <br />a <br />R <br />ELECTRICAL NOTE: <br />REPLACE BALLAST ON EXISTING FIXTURES AS NEEDED. <br />ANYTHING NOT LABLED IS CONSIDERED PROPOSED <br />I (RELOCATED nFI'.� <br />UtU s UtUIL A I tU W I Lt I <br />I'- <br />z <br />THIS IS A 24 HOUR FACILITY THEREFORE; <br />< <br />OCCUPANCY SENSORS ARE NOT REQUIRED <br />zLLI <br />IN THE MAIN EXERCISE AREA. OCC <br />SENSORS ARE REQUIRED IN THE ADJACENT <br />ROOMS AS INDICATED <br />z <br />NOTE: NO EMERGENCY BALLUSTERS <br />W <br />PROPOSED <br />pi <br />Q <br />I <br />it i ii l 1 i <br />H <br />ELECTRICAL PLAN <br />LIGHT <br />NORTH — PARKIN <br />PANEL B <br />RAINING <br />TO ALIGHTS MAIN AREA <br />MBER <br />DOOR STRIKE <br />Y <br />ABOVE <br />L o <br />ABOVE <br />FUNCTIONAL TRAINING <br />106 <br />11'-4" <br />F16 B1 <br />C2 W1 <br />1. SECURITY SYSTEM <br />2. SERVER <br />3. DOOR STRIKE <br />MANAGER <br />113 <br />11'-4" <br />F1 81 <br />C2 W1 <br />I GUEST LOB <br />�:1 <br />ENGINEER OF RECORD: <br />COOL AND COBB <br />ENGINEERING CO. <br />CERT OF AUTHIZATION #29713 <br />FL LICENS #16921 <br />203 WEST MAI ST. <br />AVON PARK, FL 33825 <br />PH. 863.657.2323 <br />DRAFTING SERVICES BY: <br />MICHAEL GARRISON <br />224 DATURA ST. #401 <br />WEST PALM BEACH, FL 33401 <br />561.835.9744 <br />ENT: <br />ORANGEWOOD <br />BUILDERS <br />1105 WEST CIRCLE ST <br />AVON PARK, FL 33825 <br />863.452.6400 <br />N <br />0 <br />J <br />a <br />D <br />z <br />< Ek <br />H c� G <br />z d W <br />W <br />0 �m� w <br />Q C <br />I QL Jc�� <br />H Z NMI Q <br />r` <br />w <br />Q � <br />W <br />IiJ <br />W <br />z <br />c� <br />N <br />G <br />RE VI SI ON S/SU BM I TTALS: <br />ID DESC DATE <br />PERMIT SUBMITTAL 112.19.11 <br />I AS BUILTS 5.11.121 <br />AWN BY: MSG <br />ECKED BY: COOL&COB <br />OJECT #: <br />TE: 5.11.12 <br />El <br />SCALE: 1 /4" = 1'-O" <br />