Laserfiche WebLink
T <br />00 <br />12 <br />5.0[ <br />FIBEREGLASS SHINLGE INSTALLED <br />AS PER MANUFACTURER <br />SPECIFICATIONS <br />FRAME <br />2ND FIN <br />T.O.M. <br />fV� <br />25-SH <br />--------------- <br />---- K1,11A <br />- — — — L—--------------------------------C— — — — <br />TEXTURED El�o�aElo� 00 <br />CEMENTITIOUS 1:1 El El D El El <br />FINISH ON 00 <br />CMU (TYP) '_ r iv <br />El E:1 El El El E:1 E:1 E�] <br />v <br />(V <br />FIN FLR <br />3068 <br />FRONT ELEVATION — B. <br />SCALE: 1/4" = 1'-0" <br />FIBEREGLASS SHINLGE INSTALLED 9'-0" RIDGE VENT <br />AS PER MANUFACTURER 12 <br />SPECIFICATIONS 5.01 - - _ -- — <br />EXTERIOR <br />PLASTER ON <br />FRAME <br />i <br />RAISED BANDS OR FOAM <br />PER COMMUNITY <br />SPECIFICATIONS <br />SCORED <br />STUCCO TYP. <br />12 CJ 25-SH CJ <br />4.0F ---------------------------- <br />--------- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />-- —------------------------------------- CXWEEP <br />co <br />r <br />v <br />R--------- <br />---------� <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON <br />CMU (TYP) <br />12 <br />— 14.0 <br />RIGHT ELEVATION — B <br />SCALE: 1/4" = 1'-0" <br />51' <br />U, <br />11) DETAIL <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. (Refer to sheet SN1 for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4"A" crown) staples @ <br />6" O.C. vertical ly/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br />eh <br />N <br />0 <br />N <br />ao 0 <br />d� <br />� W <br />a� o <br />a aR o <br />w oa o ec <br />3 = O7 <br />N CD <br />L <br />3 •0 �^ <br />G� <br />N <br />G >_ <br />�o <br />C3-OWN <br />0 <br />,e <br />s E <br />Cl <br />U1 <br />0�_x <br />_< <br />0 <br />F 1,..0 <br />0FES510 <br />��•`` <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />gM <br />C�8 0 <br />le 00 <br />0 °° <br />FA <br />0v N -"Z. <br />M # LL <br />LL <br />u. LL <br />a <br />Z r� c � a �4n <br />03 � o <br />1% S m <br />04 <br />rOIL r- <br />Z N N Z Q J <br />I� N <br />Z OU L) rb <br />W 013 <br />N <br />Z N m <br />Z � <br />da <br />¢ <br />U N <br />M <br />N z <br />v <br />a—+ <br />e <br />fa w Fe <br />C� <br />U <br />Ow <br />V) <br />c <br />U � <br />LL <br />J <br />� E <br />t 8 <br />® <br />"lam <br />U <br />O <br />M <br />Z Z <br />o <br />a <br />f0 E <br />w� <br />gOCL <br />s <br />N <br />E OU <br />H ro <br />g @ <br />o <br />ao <br />00 <br />aW <br />ruZ <br />0 <br />ru <br />� c <br />6 ❑ <br />m i <br />Z� <br />Z <br />m� <br />J <br />W�<w <br />S <br />8 <br />¢ ° <br />o <br />0 <br />Z <br />5 ° <br />aZ <br />W <br />T 3 <br />a� <br />�w <br />J <br />o <br />J= <br />W;o <br />M <br />v <br />Z* <br />a r <br />oo3 <br />L O <br />J <br />>LO <br />m <br />0 <br />0 _ <br />Cc <br />0 <br />r ^ 6 <br />v! C <br />04 <br />m <br />LO <br />`i <br />4-0 <br />r1'_- <br />0 <br />(D N <br />0) <br />N O <br />LO <br />r <br />t:M N <br />02^ <br />m <br />cM T <br />o <br />Z <br />Z <br />V y <br />E (y <br />E <br />JOB <br />NO: 23-00503 <br />SCALE : AS NOTED <br />SHEET NO. <br />2.1 <br />