Laserfiche WebLink
_ <br />i <br />FIBEREGLASS SHINLGE INSTALLED <br />AS PER MANUFACTURER <br />SPECIFICATIONS <br />12 <br />4.0-1 <br />12 <br />FIBEREGLASS SHINLGE INSTALLED 5.01 <br />AS PER MANUFACTURER <br />SPECIFICATIONS - - -- <br />4' OFF RIDGE <br />EXTERIOR <br />PLASTER ON <br />FRAME <br />CJ FLASHING <br />25-SH 25-SH 12 <br />- 14.0 <br />-------------------------------- --i — —--- — ---- <br />---- ------------- <br />—CJ/W—EEP--------- <br />35-SH <br />R... 1------------------------- <br />I' <br />6068 SGD <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON <br />CMU (TYP) <br />REAR ELEVATION — B <br />SCALE: 1/4" = 1'-0" <br />9'-0" RIDGE VENT <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON <br />CMU (TYP) <br />12 <br />14.0 <br />2ND <br />-�--------- <br />FIN FLR <br />LEFT ELEVATI <br />SCALE: 1 /4" = V-0" <br />N — B <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. (Refer to sheet SN1 for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4"A" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br />0 <br />N <br />ao � <br />� o <br />CL_ .o <br />Q d� <br />O <br />CV <br />C 16 d <br />N <br />Cc <br />N -O CV S <br />Q m CV fC <br />� <br />3 <br />� <br />�dCD <br />�. <br />as <br />� <br />9• GC • A <br />v1 CL Q <br />C <br />� O <br />G1. V <br />e� <br />OWN <br />:• V <br />— � Q `'p.&14P <br />'� '•. F LO ..• 40 <br />1l 111111 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />Wd. E0 co <br />QO U <br />N O <br />N �p <br />v+ <br />0 a00 G tGl i0 <br />d J <br />Lu <br />a <br />_J Lu <br />m c rn a <br />C1133 <br />L r0 <br />5 _ <br />�. <br />e4� <br />Win�OjO' m <br />Z 0. <br />,n N z ¢LL J <br />N <br />OU U <br />= <br />W [313 <br />M <br />Z RU) <br />z o <br />J — <br />d <br />N <br />M <br />:n Z c <br />U <br />� s <br />LL <br />4 Cn <br />CQ W <br />� a <br />m <br />U <br />0 W 8 <br />V) c "' <br />-3 <br />U <br />W J <br />E <br />_ g <br />min <br />i <br />! <br />z� <br />® Q 0 <br />sm <br />Z <br />M <br />z <br />o <br />4 <br />U_ <br />N <br />z o <br />N <br />4 0 <br />Q <br />a- o <br />E U <br />W z <br />Z <br />oa <br />F� r0 <br />�� <br />�� <br />��oa <br />�o <br />Z <br />o <br />wZ <br />C: <br />�_ <br />o�ZZ <br />m� <br />o� <br />Z <br />m <br />5 J <br />O <br />w <br />QW z <br />� <br />$ <br />F� <br />o� <br />go <br />oLL <br />-W <br />rk <br />ao <br />M <br />w <br />ww <br />�~ <br />LF <br />_�� <br />° <br />0 <br />c Q <br />Lo <br />J <br />m <br />m <br />co co <br />^. <br />C) <br />U) <br />I— <br />CoLO <br />C <br />0 - <br />CO <br />ca <br />'� co <br />0) <br />.� N O <br />LO <br />E <br />c M <br />z <br />l0 <br />N T <br />M <br />E v «3 <br />c <br />JOB <br />NO: 23-00503 <br />SCALE : AS NOTED <br />SHEET NO. <br />2.2 <br />