My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38022-38040 Fallstone Way
Zephyrhills
>
Building Department
>
Building Plans
>
38022-38040 Fallstone Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 1:07:03 PM
Creation date
2/27/2025 11:18:16 AM
Metadata
Fields
Template:
Building Plans
Street #
38022-38040
Location
Fallstone Way
Contractor
Lennar Homes
Building Plans - Permit #
6192-6199
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits In all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7, Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11.In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />PTF <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />fLph <br />� SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />�4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />IO EXHAUST FAN <br />; WIN � EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />P� PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />©2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />D9 ELECTRIC METER <br />Ja ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />C\�� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />GD (1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I <br />rI HE <br />I <br />BC <br />I I <br />LAV T� <br />I` <br />TUB/ ` <br />W/C SHOWER <br />LAV <br />3" VTR <br />JL <br />I <br />I <br />I <br />I <br />I <br />I OPT. <br />LAV LAV <br />I <br />I <br />cU U W/C <br />SHOWER <br />—3" <br />STUDOR <br />VENTq I ' DBL SINK <br />L l� W/ DISP. <br />W/C <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />UNIT -A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />OTHER WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />st 10 KW at100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />1 5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />NEMA t <br />200 AMP <br />� CTCr7 AAA dl <br />1 0-200 A P Serial Cable <br />NEMA <br />3R _j <br />C.O. <br />Power Co. Feed #4 Solid COPPER Ground <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 -17, LOCAL CODES AND THE LOCAL POWER CO. <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT <br />ROUGH -IN <br />FOR OPT. `��fi�� <br />FAN/LIGHT i WP <br />GFI <br />I% <br />� GFI <br />/ I <br />� E <br />DINING �� I <br />KITCHEN 1 <br />FIWW <br />I O <br />--- <br />---_ --- GFI � --- <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br />/�>ROUGH-IN\ <br />_ �� FOR OPT. <br /><,'UN FAN/LIGHT' <br />r� I <br />- I <br />1 / <br />FOYER "�,_ <br />r <br />I I <br />I <br />I DB <br />ENtRY o- <br />LIGHT AS 0 GFI@ <br />PEAR SPECS <br />DB&GFI TO <br />BE ALIGNED <br />VERTICALLY <br />I <br />I <br />I <br />r-CIEL — _j <br />C.M <br />1 UPSTAIRS t <br />GFI <br />@ 44" <br />\ <br />W.H. <br />A.F.F. <br />' <br />\ 0 <br />/ <br />1 <br />I GARAGE <br />\ <br />GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />O <br />DOOR <br />GFI <br />r-----------------� <br />I <br />I <br />I <br />I � <br />bZ <br />I <br />I <br />Fa <br />I <br />I <br />Q <br />I <br />I <br />I <br />W <br />I <br />>W <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL -UNIT-A 1532 <br />SCALE: Y"=1'-0" <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />_ .---—-----—— — — — -- I <br />OWNER'S <br />BEDROOM <br />/-\ROUGH-IN <br />FOR OPT. <br />FAN/LIGHT <br />I <br />S.D <br />0. BATH <br />'+f <br />Al <br />I <br />• �� LOFT <br />`BATH 2 <br />S.D � <br />GFI <br />I WIC <br />I <br />L------ /,>ROUGH -IN <br />---- FOR OPT. <br />FAN/LIGHT <br />BEDROOM 2 <br />2ND ELECTRICAL -UNIT-A 1532 <br />SCALE: X"=V-0" <br />s•a <br />c*•i <br />0 <br />C%8 <br />C" <br />cV ... <br />Q 'a <br />y W <br />O <br />ra A <br />m <br />u. <br />c E <br />tG p <br />R. U <br />Ci <br />N <br />N <br />O <br />��11191Jizl.•� <br />r� <br />P�. <br />Sir"t'FE OF � Z <br />err u U r . • Cis• �y'• <br />•,,�� � �� Pia A � E <br />�+iisrlua►a��, `r�� <br />To the best of the Engineers knowledge, information end belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature end seal. <br />j <br />N OI <br />Co N <br />0 � G N co <br />r0 LL <br />N <br />i) y rj v J , <br />a C <br />lu L u d <br />Z CO a iY� <br />SO <br />L � 2 <br />W �.- o <br />m 9 <br />W rR�°�. . <br />In wZ a 0 <br />a <br />* OU <br />W 0 a <br />04 Q <br />z � <br />z � <br />Q � <br />M <br />U) <br />fa w <br />0 w g <br />Ln <br />U <br />w J <br />U � <br />c <br />Q 0 <br />• <br />� 0 <br />N �, <br />sm <br />o <br />Wo <br />QE <br />o <br />=® <br />F— <br />o0 <br />00 <br />g E <br />�0x <br />Z <br />CO rp <br />M <br />°fi <br /><� <br />wx <br />J <br />N. C <br />4 <br />y <br />m� <br />too`6 <br />LL <br />m a� <br />J <br />�a <br />2 <br />tiw <br />15 <br />T� <br />a ° <br />w <br />2 7 <br />p <br />az <br />W° <br />Lop <br />W <br />�? <br />> cj- <br />N <br />UW <br />CO <br />9. <br />T— <br />m <br />�' <br />E 'S <br />_ <br />O <br />T <br />_ <br />c0 <br />O <br />M <br />00 <br />r <br />CoC <br />CD <br />LL <br />o <br />600 <br />E N ch <br />N <br />~ <br />r M N <br />c <br />O LO <br />O <br />O <br />LO <br />\V <br />M <br />T <br />E <br />CO <br />o <br />Z <br />W <br />Z <br />O rn <br />E O ai <br />`W <br />U <br />c <br />a <br />Q 0 <br />JOB <br />NO: 23-00590-00583 <br />SCALE : AS NOTED <br />SHEET NO. <br />Is <br />
The URL can be used to link to this page
Your browser does not support the video tag.