My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38022-38040 Fallstone Way
Zephyrhills
>
Building Department
>
Building Plans
>
38022-38040 Fallstone Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 1:07:03 PM
Creation date
2/27/2025 11:18:16 AM
Metadata
Fields
Template:
Building Plans
Street #
38022-38040
Location
Fallstone Way
Contractor
Lennar Homes
Building Plans - Permit #
6192-6199
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan Is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11.In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles In laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range Is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FE76. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />4W <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />& . <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />0 <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />1,,nl <br />CHIMES (OPTIONAL) <br />P� <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F9 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />-a <br />ELECTRIC PANEL <br />_i <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ROUGH-IN FOR <br />G J <br />OPT. CEILING FAN <br />89 <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />JL <br />I <br />I <br />I <br />I <br />j — I HANSON <br />BOX <br />I I <br />LAV 'I�_ _ I <br />el- <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />OPT. <br />LAV <br />�2^d F <br />LOAD CALCULATIONS <br />UNIT-C 1624 (1624) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1625 S.F. <br />4875 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10875 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33935 <br />_70m— <br />1st 10 KW at <br />BALANCE OF WATTS AT 0% <br />9574 <br />AIR CONDITIONER WATTS AT 00% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />1 5200 <br />TOTAL: 31878 <br />LOAD WATTS -- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />0 <br />DISCONNECT <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT <br />ROUGH -IN <br />FOR OPT. / l�/r�� <br />FAN/LIGHT i WP <br />.n. <br />DINING <br />KITCHEN <br />GFI ( <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br /><%\ /,,>ROUGH -IN\ <br />J" f FOR OPT. <br />FAN/LIGHT 1 <br />/ I <br />I <br />1 / <br />DB <br />NTRY WP0 <br />IGHT AS 0 GFI <br />ER SPECS <br />DB & GFI TO <br />BE ALIGNED I <br />VERTICALLY <br />rl <br />f/ <br />Optional Overhead Service 200A / <br />Same As Underground Indoor Panel If <br />150 Or 200 Amp Service Center 2 <br />NEMA 1 � <br />20o AMP ZZ <br />�w <br />TER MA N ` U <br />1 0-200 A P Serial Cable ,lye 0 <br />NEMA ? �� <br />3R <br />Power Co. Feed —� �r #4 Solid COPPER Ground <br />II <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least V apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />I <br />I <br />I <br />I <br />I <br />I <br />C.M <br />j UPSTAIRS F <br />G <br />44" <br />` \ <br />LW.H� <br />A.F.F. <br />1 <br />\ p <br />I <br />1 <br />I <br />I GARAG E <br />1 <br />GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />DOOR <br />GFI <br />--------------- <br />I <br />I <br />J <br />I <br />I <br />I0 Z <br />I <br />IQ <br />1 <br />10 Q <br />I <br />ILL• U <br />I <br />I la: w <br />I <br />h ,J <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />1ST ELECTRICAL -UNIT-C 1624 <br />SCALE: Y"=1'-0" <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />F- - _ _ ___ __ _.__ _.- - _.._. <br />2ND ELECTRICAL -UNIT-C 1624 <br />SCALE: Y"=1'-0" <br />M <br />CV <br />0 <br />c-s <br />C" <br />N <br />yo w <br />C� <br />N <br />"a M X <br />C L.6 Cl <br />N <br />V v = C <br />C <br />-Cc N <br />3 d <br />M .= fU <br />C <br />s 3 � <br />16 N N .L7 <br />v ti -G <br />c 1= <br />d U <br />0 <br />N <br />LO <br />N <br />a <br />.�,15 t t it l `_ 4�• �LJ JJ <br />�• STACF <br />a. <br />IAL��� <br />JJiJ?frs,;211j%%% <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />O <br />N <br />c n <br />040 <br />o <br />dJ <br />rn N o <br />C <br />J LL <br />J LL LL GW <br />Lu <br />= <br />Ot <br />m c °f n <br />tpC'co a <br />W <br />W <br />� °' m <br />00 0 <br />`r' c� Z d <br />N O U U <br />W <br />U <br />❑❑ <br />CD�V <br />0 <br />Z N Q <br />U) <br />V) <br />l7 <br />z <br />NC!) <br />.O <br />o <br />a, <br />J <br />I <br />v <br />0 <br />see <br />r•- <br />W <br />M <br />9 <br />L.L. <br />`S- E <br />o <br />�Q <br />E O <br />k <br />Da <br />H <br />E <br />Id <br />�g <br />u7 <br />O U <br />a= <br />1Z <br />Z <br />t <br />a <br />�o <br />ro <br />06 <br />m� <br />Z <br />M J <br />2 <br />� <br /><? <br />fN <br />WT <br />N_W <br />m <br />H <br />N <br />O <br />WO <br />Z� <br />T <br />o� <br />C� <br />N <br />CC> <br />T <br />O <br />co <br />G'V <br />00 <br />o <br />C m <br />O <br />E <br />Ll_ <br />o <br />N <br />:3 <br />F=-- <br />00 O <br />o <br />Or <br />a to <br />00 <br />00 <br />CO <br />00 N <br />r <br />S <br />O <br />M <br />o <br />z <br />E <br />M <br />a. <br />v � <br />¢ o <br />JOB <br />NO: 23-00590-00583 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />11.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.