Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />c <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />P4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />;Q� <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />Owl <br />ELECTRIC PANEL <br />_mot <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W! ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />6� <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />jJHANSONBOX <br />I <br />LAV <br />OPT <br />LAV LAV <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />Unit -A- (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />1 5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />)ptional Overhead Service <br />lame As Underground <br />50 Or 200 Amp Service <br />Power Co. Feed <br />Intersystem Bonding <br />Termination Per <br />200A <br />Indoor Panel <br />Center <br />Cable <br />#4 Solid COPPER Ground <br />NEC 08, 250.94 <br />Rods at least V apart <br />typical 150-200 Amp Electrical Riser Diagram <br />TOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />'HE NFPA 70 -17, LOCAL CODES AND THE LOCAL POWER CO. <br />of <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT <br />ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />`� �' W <br />in% <br />Q) (U)GFI <br />k� <br />DINING <br />KITCHEN I <br />I <br />FI 0 <br />__j_- <br />--- --- GFI (-- <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br />�At ��>ROUGH-IN\ <br />FOR OPT. <br />FAN/LIGHT <br />/ y <br />I <br />l <br />I � f <br />I <br />DB <br />EN <br />tRY WP0 <br />LIGHT AS 0 GFI® <br />PER SPECS <br />DB & GFI TO <br />BE ALIGNED _ <br />VERTICALLY <br />\ H� <br />WZ <br />Lno Q <br />L <br />cr U =� <br />>_jm <br />C.M <br />1 UPSTAIRS t <br />GFI <br />@ 44" <br />` \ <br />A.F.F. <br />t ` 0 <br />I GARAGE <br />GARAGE <br />LIGHT AS <br />NPER SPECS <br />GARAGE <br />DOOR <br />GFI <br />r-----------------t <br />I I <br />I <br />I <br />J <br />I <br />I <br />Ip Z <br />I <br />1� a <br />IQ <br />I <br />I <br />J <br />I� Q <br />I <br />` D U <br />i <br />0 <br />ILL <br />U <br />I <br />1 <br />ILU J <br />I <br />h t�l <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL -UNIT-A 1532 <br />SCALE: y4'=V-0" <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I — <br />2ND ELECTRICAL - UNIT -A 1532 <br />SCALE: y4'=V-0" <br />N <br />�a <br />CV. <br />d` <br />_. <br />C3 <br />1 <br />N <br />_N <br />N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 Florida Building Code <br />- <br />Residential <br />7th Edition. Engineer's <br />signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />and seal. <br />�' I- u)I <br />tsiggnature <br />F1@ <br />EE <br />I <br />N 8 <br />I� <br />O <br />0 <br />CO <br />N 0 <br />J <br />Q <br />�g5g5 <br />C J 2 LL <br />ul <br />LL u- S a <br />,^ <br />V <br />z <br />J _ W <br />vs <br />��� <br />Z <br />Co N <br />CO J <br />Z <br />� <br />LO M C <br />of <br />of 0 <br />Z <br />W <br />❑❑ <br />�J1{ <br />✓ M L�2 <br />0 <br />¢N <br />Z o <br />� <br />n� <br />N <br />M <br />Z a <br />VJ <br />V{ L <br />o <br />C6 <br />W <br />O <br />�y N <br />tJ <br />Q <br />CD <br />co <br />w <br />CM <br />M <br />¢ <br />p <br />Z <br />o <br />a o <br />E: <br />w� <br />Z® <br />z <br />O <br />SQ <br />N @ <br />a� <br />a z <br />O <br />ww <br />L <br />W <br />¢ o <br />W <br />M <br />V Y <br />01 <br />U, <br />m <br />aw <br />� Z <br />v <br />o <br />° g <br />CL <br />w� <br />�F <br />C) <br />az <br />2� <br />o <br />w� <br />L <br />>° <br />NJ <br />cozl< <br />w <br />a� <br />3 <br />o T. <br />a; <br />� <br />N <br />Uro <br />O <br />c-- <br />E co <br />c� <br />O <br />C <br />' <br />M <br />^ <br />L.L <br />O <br />j <br />CSC <br />U <br />mCo <br />o <br />U_ <br />O <br />00 <br />r <br />� <br />O <br />O N <br />U.­) <br />F=— <br />�-J O <br />oo C) <br />M N <br />O <br />= <br />d <br />N N <br />(6 <br />r <br />T <br />N <br />E <br />'c 0 <br />Ch r <br />iri <br />Z <br />ro <br />Z <br />E Oca <br />@ <br />E <br />a ui <br />c <br />it <br />U � <br />Q Q <br />JOB <br />NO: 22-12552-12545 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />13 <br />