ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSULIL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />(� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />I_o <br />WALL MOUNTED LIGHT FIXTURE <br />© <br />RECESSED LIGHT FIXTURE <br />+P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />,Or <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />[BD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />N <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />Wi <br />ELECTRIC METER <br />W-W71_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />r <br />I I <br />I I <br />I I <br />LAV <br />L TUB/ <br />WIC SHOWER <br />LAV <br />3" VTR <br />JIL <br />I <br />I <br />I <br />I <br />I <br />I OPT. <br />I LAV <br />LAV <br />I J— <br />_U WIC <br />SHOWER <br />STUDOR <br />VENTq '' II DBL SINK <br />L h W/ DISP. <br />W/C <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />— <br />Unit -B- (1516) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1505 S.F. <br />4515 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10515 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33575 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9430 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31734 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />P I � " NEMA t <br />2tX1 AMP <br />T=. AAA . <br />1 �0-200 Af P I I T /—Serial Cable <br />3R <br />Power Co. Feed ---\ I1 i #4 Solid COPPER Ground <br />C.O. <br />I� <br />Intersystem Bonding <br />Termination Per <br />NEC 08, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />DISCONNECT <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />- ----------------------- <br />OUTDOOR LIVING <br />JA <br />INSTALL LIGHT <br />ROUGH -IN <br /><�hfi�� FOR OPT. <br />GFI J IFAN/LIGHT <br />.n, <br />GFI / <br />I 1 <br />DINING <br />KITCHEN <br />I <br />�I <br />I � <br />L_SaEI-1 [0 1 <br />--- (�1 GFI --- <br />DISPOSAL IN CAB <br />C.M. UNDER SINK <br />1 � <br />II � <br />GREAT ROOM <br />ROUGH-IN<�� <br />CH FOR OPT. <br />' FAN/LIGHT��fi�``'� <br />\ I 1 <br />UPSTAIRS <br />I <br />—6 <br />1 <br />FI i FOYER <br />GFI / <br />@ 44" / <br />0 ` ' A.F.F. --,. <br />1 I <br />I � GARAG E 1 ` DBWp ENTR <br />GFI 0 LIGHT A <br />I PER SPEC <br />DB & GFI TO <br />GARAGE BE ALIGNED <br />LIGHT AS I VERTICALLY <br />PER SPECS <br />GARAGE _ <br />DOOR <br />GFI <br />r------------------ <br />I I <br />I ZIW \ <br />I O IQ \ <br />I Q lo- <br />I C) Ia ? \ <br />I t}i... I►- W Z <br />I Iw _ <br />I WIC �►-LU <br />>Iw �U=� <br />CO <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />1ST ELECTRICAL - UNIT-B 1516 <br />SCALE: y4"=V-0" <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES, <br />2ND ELECTRICAL -UNIT-B 1516 <br />SCALE: ya'=1'-0" <br />C%4 <br />eau <br />N <br />.C�4 <br />c eo t� <br />r � <br />CV �. <br />_Q <br />—W <br />sa ca .tea <br />iv <br />eM t:a <br />s, <br />N <br />0 <br />N <br />N <br />To the best <br />of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />z � <br />- W <br />F' <br />a <br />v E <br />8 <br />h <br />O <br />O <br />No NO rn m ti <br />W <br />�LLtL 3 w a <br />° <br />Z13 <br />m = <br />_ <br />w 2o �' <br />W. <br />��f6 C"F O 1 <br />W <br />Z <br />tq T . m w <br />to M Z QIL J <br />Z <br />(V J <br />OU <br />❑❑ <br />Z N M <br />0 <br />� <br />o <br />J — <br />Q. � <br />U)V) <br />z <br />v0o <br />+-1 <br />(� <br />u, g <br />U <br />0 <br />to <br />�V) <br />LU g <br />= 3 <br />U <br />= p.,... <br />, , ,o <br />F— J E <br />U o �3 <br />¢ Y <br />� m <br />m <br />�m <br />ti <br />ffi <br />M <br />M <br />N <br />o <br />Z <br />Li- <br />Z <br />O <br />Z. <br />< N <br />Q <br />E: O <br />u <br />z <br />K°=° <br />N <br />i <br /><o <br />o� <br />mod❑ <br />�? <br />v <br />c <br />O <br />ow <br />oLL <br />Z' <br />Ztt�� <br />C <br />J <br />° <br />z <br />to <br />< <br />Og <br />za U <br />U <br />a <br />U <br />�o <br />�- <br />r3 <br />C <br />-Z <br />o <br />w <br />a <br />v <br />zQ <br />° <br />0 r <br />LL <br />i1) <br />rn <br />N <br />f <br />C7 <br />GD <br />�, <br />CCD <br />Ds-- <br />r <br />Cf� <br />� <br />� <br />3: <br />co <br />c <br />CD <br />o <br />I <br />r <br />o <br />m <br />CcO <br />00 <br />� <br />CD <br />cN <br />CD <br />00 <br />N N <br />O <br />Q <br />00 <br />r <br />C9 <br />CD <br />r <br />w <br />04 <br />M — <br />.. <br />° <br />E <br />E <br />CD <br />N <br />Z <br />Z <br />E <br />B <br />a <br />E <br />0 _j <br />¢ o <br />JOB <br />NO: 22-12552-12545 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />14 <br />