Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit Is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included In the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />piiip <br />HALF -SWITCHED DUPLEX OUTLET <br />f� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />�3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />JR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />1-H <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F9 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />LL <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />i <br />I <br />I I <br />I I <br />I I <br />� I I <br />LAV <br />.J I <br />L TUB/ <br />W/C SHOWER <br />LAV <br />ti W/C <br />SHOWER <br />_.znd � FAR <br />STUDOR <br />VENTI , DBL SINK <br />T� W/ DISP. <br />W/C <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />Unit -A- (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />96 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />THER LOAD <br />OTHER WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10 KW at 1 0 <br />1000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS -- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />)ptional Overhead Service <br />lame As Underground <br />50 Or 200 Amp Service <br />Power Co. Feed <br />Intersystem Bonding <br />Termination Per <br />C 0 94 <br />200A <br />Indoor Panel <br />Center <br />Cable <br />#4 Solid COPOIER Ground <br />Rods at least 6' apart <br />typical 150-200 Amp Electrical Riser Diagram <br />TOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />-HE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />C.O. <br />a <br />DISCONNECT <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />OUTDOOR LIVING ~ <br />I I <br />INSTALL LIGHT ��S /i> <br />ROUGH -IN / <br />FOR OPT. < <br />FAN/LIGHT j `� GFI <br />. V, <br />-(ID (GFI <br />1 <br />DINING <br />KITCHEN 1 <br />"o, 6FI �O <br />GFI <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />141 <br />GREAT ROOM <br /><,\ /�>ROUGH-IN\ <br />`H' FOR OPT. 1 <br /><FAN/LIGHT ` <br />I <br />1 / <br />FOYER '�,, <br />I <br />I\VADB <br />EN RY I WPo- <br />LIG TAS70j,,,eGF19 <br />PER SPECS <br />DB&GFI TO <br />BE ALIGNED <br />VERTICALLY <br />C.M <br />DEDICATED <br />►i0ORECEPTACLE FOR <br />_ �.�MICROWAVE <br />►.. <br />.,.; RANGE HOOD PER <br />j UPSTAIRS t <br />11 NA%71 - en ii "�l - -, OWN <br />GFI <br />@ 44" <br />` \ <br />` `LW.H. <br />A.F.F. <br />` \ 0 <br />I \ <br />1 <br />GARAGE <br />I I <br />1 <br />GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />*DOOR <br />GFI <br />r— — — — — — — — — — — — — — — -- <br />I I <br />I <br />I J <br />I <br />I <br />I0 Z <br />I <br />IQ <br />IO Q <br />I <br />IW J <br />I <br />la In <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />1ST ELECTRICAL - UNIT -A 1532, <br />L___ --- -- -- ---- — — — -- - - __ . <br />2ND ELECTRICAL - UNIT -A 1532 <br />SCALE: Y4"=1'-0" <br />0 <br />N <br />ca <br />d <br />> W <br />0 <br />N <br />�mx <br />W_ d- <br />viC <br />M O ► <br />N y O J <br />C'V 9C <br />� N <br />E s C. <br />d Ca <br />co <br />E <br />b o <br />0 <br />0 <br />� N <br />N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />40 <br />W <br />C <br />00 <br />ENO <br />Q <br />�► <br />47 co < J , <br />C J LL W <br />LL <br />= <br />13 <br />LL <br />uj <br />tMg o <br />W <br />0 <br />W <br />^- <br />I °' °. m <br />Z <br />IL <br />IL <br />MZ d <br />z <br />OU9� <br />W <br />N <br />z <br />z <br />Z <br />� <br />QJ <br />� <br />4- <br />O <br />c <br />w <br />o <br />U <br />E <br />sff <br />ao <br />Q <br />0 <br />Z <br />E <br />N <br />6�gw� <br />E <br />CO� <br />�rz <br />g <br />Z <br />gi <br />8f <br />0 <br />g <br />W <br />T <br />6 <br />Nw <br />o T— <br />o . <br />iu <br />T <br />t6 <br />cv <br />00 <br />T <br />co <br />C <br />O <br />n <br />r <br />s <br />C m <br />co <br />O <br />0o <br />U_ <br />O <br />T <br />00 <br />O N <br />U-) <br />00 O <br />c <br />9 <br />N <br />pOj <br />M <br />U.) <br />00 <br />00N <br />ui <br />4 <br />CDN <br />M r <br />c <br />Z <br />Z <br />E <br />E <br />L <br />c <br />� <br />0- <br />E <br />ci <br />:3 <br />¢ o <br />JOB <br />NO: 22-12568-12561 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />13 <br />