My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38049-38075 Fallstone Way
Zephyrhills
>
Building Department
>
Building Plans
>
38049-38075 Fallstone Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:11:50 PM
Creation date
2/27/2025 11:19:02 AM
Metadata
Fields
Template:
Building Plans
Street #
38049-38075
Location
Fallstone Way
Contractor
Lennar Homes
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan Is Intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed In accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits In all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined In UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />VIM <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />f <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />Qr <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />FP <br />PUSH BUTTON SWITCH (OPTIONAL) <br />HO <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />J <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />��19 <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />0 <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />44 <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />r'. I I <br />I I <br />I I <br />I I <br />T` I <br />LAV <br />.j I <br />L TUB/ <br />W/C SHOWER <br />LAV <br />3" VTR <br />)IL <br />I <br />I <br />I <br />I <br />I <br />I OPT. <br />LAV <br />LAV <br />I <br />I <br />Ll ti W/C <br />SHOWER <br />STUDOR <br />VENTT LrJ DBL SINK <br />W/ DISP. <br />W/C <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />Unit -B- (1516) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1505 S.F. <br />4515 <br />MALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10515 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33575 <br />1st 10 KW at <br />10 <br />BALAN E OF WATTS AT 40% <br />9430 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31734 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />NEMA1 <br />21N1 AMP <br />� Tin un w� <br />1 ki0-200 A10 I I T /—Serial Cable <br />3R <br />Power Co. Feed ---� 11 1_ l.r-- #4 Solid COPPER Ground <br />N-003 <br />I <br />Intersystem Bonding <br />Termination Per <br />NEC 08, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />DISCONNECT <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />a <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />L_LZ <br />ED <br />A UPSTAIRSF <br />—— — — — — — — — — — — — — — — — — — — <br />OUTDOOR LIVING <br />�;i� INSTALL LIGHT <br />ROUGH -IN <br />FOR OPT. <br />GFI 1 AN/LIGHT <br />I'm <br />KITCHEN <br />I <br />o I G <br />GFI <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br />ROUGH-IN"��> <br />FOR OPT.C/, <br />' FAN/LIGHT Y <br />I <br />I 1 <br />1 I <br />I <br />W.H. <br />0 / <br />A. <br />1mom <br />I <br />\ <br />GARAGE1 <br />I <br />I <br />GARAGE <br />1 <br />LIGHT AS <br />/ <br />PER SPECS <br />GARAGE <br />DOOR <br />GFI <br />--------------- <br />I <br />I <br />I <br />Lj <br />I <br />ZIW - <br />01� <br />I <br />I <br />Q la <br />IQ <br />I <br />U <br />03 <br />I <br />�L I� <br />IC <br />I <br />rW <br />> 11.4 <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DB <br />-0WP I ENT <br />@GFI b LIGHT <br />PER SPE <br />—��°m 1/ <br />/ <br />DB & GFI TO <br />BE ALIGNED <br />VERTICALLY <br />1ST ELECTRICAL -UNIT-B 1516 <br />SCALE: Y4"=1'-0" <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />2ND ELECTRICAL - UNIT-B 1516 <br />SCALE: Y4"=V-0" <br />M <br />N <br />N <br />,a <br />d <br />> w <br />Z <br />C= <br />c N <br />eta <br />.Q mx <br />N f0 C7 <br />>m�Q <br />w <br />�dd� <br />�. C-) d <br />C O <br />dcc <br />a�•a� <br />c E <br />o <br />a <br />w <br />4 <br />N <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />a <br />0LoF� <br />E <br />N N 8 S <br />0 <br />W <br />a <br />�rNi0 <br />LL a <br />Z <br />U.u- <br />MC14� <br />m <br />I <br />z <br />IL <br />L <br />tR�O�jO. w <br />r" Z a r <br />Cl) <br />z <br />N OU v <br />W <br />pp <br />z <br />z <br />a ; <br />z <br />� <br />.O <br />W W <br />o <br />� <br />N <br />c <br />U <br />a <br />..p <br />N <br />M <br />J <br />E <br />a° <br />zo <br />Z <br />Nt$ <br />L L <br />c <br />YY. <br />NV <br />°LL <br />zr <br />YZ <br />Z�c <br />NZ <br />WU <br />g <br />•� T <br />d' <br />T <br />Ly <br />L <br />m <br />e <br />t:M <br />N <br />N— <br /><6_ <br />00 <br />�— <br />co <br />C <br />O <br />_M <br />n <br />s+ <br />V <br />ti <br />O <br />O <br />6o <br />T <br />ELo <br />00 <br />8 N <br />Lo <br />H <br />OCD <br />M N <br />rn <br />Q . <br />CV <br />r <br />O <br />00 <br />E <br />00 04 <br />ch T <br />r <br />0 <br />Z <br />m <br />E O <br />N <br />B :3 <br />� <br />M <br />FL <br />U _ <br />Q o <br />c <br />3 <br />JOB <br />NO: 22-12568-12561 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />14 <br />