ENGINEERING <br />SPECIFICATIONS <br />PRODUCT DESCRIPTION <br />HIGH STRENGTH PRECAST CONCRETE LINTELS DESIGNED TO BE UNFILLED OR FILLED TO FORM A COMPOSITE REINFORCED BEAM USING CONCRETE MASONRY UNITS. <br />MATERIALS <br />• F'C 8" PRECAST LINTELS = 3500 PSI <br />• F'C 8" PRESTRESSED, 6" AND 12" PRECAST LINTELS = 6000 PSI <br />• F'C 4" PRECAST LINTELS = 3000 PSI <br />• GROUT PER ASTM C476 F'G = 3000 PSI W/ MAXIMUM <br />3/8 INCH AGGREGATE AND 8 TO 11 INCH SLUMP. <br />GENERAL NOTES <br />1. PROVIDE FULL MORTAR HEAD AND BED JOINTS. <br />2. SHORE FILLED LINTELS AS REQUIRED. <br />3. INSTALLATION OF LINTEL MUST COMPLY WITH <br />ARCHITECTURAL AND/OR STRUCTURAL DRAWINGS. <br />4. U-LINTELS ARE MANUFACTURED WITH 5-1/2 INCH LONG <br />NOTCHES AT ENDS TO ACCOMMODATE VERTICAL CELL <br />REINFORCING AND GROUTING. <br />5. ALL LINTELS MEET OR EXCEED U360 VERTICAL <br />DEFLECTION, EXCEPT LINTELS 17'-4" AND LONGER WITH A <br />NOMINAL HEIGHT OF 8" MEET OR EXCEED U180. <br />6. BOTTOM FIELD ADDED REBAR TO BE LOCATED AT THE <br />BOTTOM OF LINTEL CAVITY. <br />7. 7/32 INCH DIAMETER WIRE STIRRUPS ARE WELDED TO THE <br />BOTTOM STEE'- FOR MECHANICAL ANCHORAGE. <br />SAFE LOAD TABLE NOTES <br />1. ALL VALUES BASED ON MINIMUM 4 INCH NOMINAL BEARING. <br />EXCEPTION: SAFE LOADS FOR UNFILLED LINTELS MUST BE REDUCED <br />BY 20 % IF BEARING LENGTH IS LESS THAN 6-1/2 INCHES. <br />2. N.R. = NOT RATED. <br />3. SAFE LOADS ARE SUPERIMPOSED ALLOWABLE LOAD. <br />4. SAFE LOADS BASED ON GRADE 40 OR GRADE 60 FIELD REBAR. <br />5. ADDITIONAL LATERAL LOAD CAPACITY CAN BE OBTAINED BY THE <br />DESIGNER BY PROVIDING ADDITIONAL REINFORCED MASONRY <br />ABOVE THE PRECAST LINTEL. SEE REINFORCED CMU ON PAGE 4. <br />6. ONE #7 REBAR MAY BE SUBSTITUTED FOR TWO #5 REBARS IN 8" <br />LINTELS ONLY. <br />7. THE DESIGNER MAY EVALUATE CONCENTRATED LOADS FROM THE <br />SAFE LOAD TABLES BY CALCULATING THE MAXIMUM RESISTING <br />MOMENT AND SHEAR AT D-AWAY FROM THE FACE OF SUPPORT. <br />• CONCRETE MASONRY UNITS (CMU) PER ASTM C90 WITH <br />MINIMUM NET AREA COMPRESSIVE STRENGTH = 1900 PSI <br />• REBAR PER ASTM A615 GRADE 60 <br />• PRESTRESSING STRAND PER ASTM A416 GRADE 270 LOW RELAXATION <br />• 7/32 INCH WIRE PER ASTM A510 <br />• MORTAR PER ASTM C270 TYPE M OR S <br />8. CAST -IN -PLACE CONCRETE MAY BE PROVIDED IN COMPOSITE LINTEL IN <br />LIEU OF CONCRETE MASONRY UNITS. <br />9. SAFE LOAD RATINGS BASED ON RATIONAL DESIGN ANALYSIS PER ACI <br />318 AND ACI 530 <br />10. PRODUCT APPROVALS: MIAMI DADE COUNTY, FLORIDA NOS. 03-0605.05 <br />AND 03-0605.04 <br />11. THE EXTERIOR SURFACE OF LINTELS INSTALLED IN EXTERIOR <br />CONCRETE MASONRY WALLS SHALL HAVE A COATING OF STUCCO <br />APPLIED IN ACCORDANCE WITH ASTM C926 OR OTHER APPROVED <br />COATING. <br />12. LINTELS LOADED SIMULTANEOUSLY WITH VERTICAL (GRAVITY OR <br />UPLIFT) AND HORIZONTAL (LATERAL) LOADS SHOULD BE CHECKED FOR <br />THE COMBINED LOADING WITH THE FOLLOWING EQUATION: <br />APPLIED VERTICAL LOAD + APPLIED HORIZONTAL LOAD 1.0 <br />SAFE VERTICAL LOAD SAFE HORIZONTAL LOAD <br />8. FOR COMPOSITE LINTEL HEIGHTS NOT SHOWN, USE SAFE <br />LOAD FROM NEXT LOWER HEIGHT. <br />9. FOR LINTEL LENGTHS NOT SHOWN, USE SAFE LOAD FROM <br />NEXT LONGEST LENGTH. <br />10. ALL SAFE LOADS IN UNITS OF POUNDS PER LINEAR FOOT. <br />11. ALL SAFE LOADS BASED ON SIMPLY SUPPORTED SPAN. <br />12. THE NUMBER IN THE PARENTHESIS INDICATES THE <br />PERCENT REDUCTION FOR GRADE 40 FIELD ADDED REBAR. <br />EXAMPLE: T-6" LINTEL TYPE 8F32-1 B SAFE GRAVITY LOAD = <br />6472 (15) W/ 15% REDUCTION => 6472 (.85) = 5501 PLF <br />SAFE LOAD TABLES <br />For Gravity, Uplift & Lateral Loads <br />SAFE GRAVITY LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS <br />C� SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8F8-0B BF12-0B BF16-08 8F20-0B 8F24-0B BF28-0B 8F32-0B <br />LENGTH 8U8 8F8.1B 8F12-1B 8F16-1B BF20.16 8F24-16 8F28.1B 8F32-1B <br />2'-10" (34") PRECAST 2231 3069 4605 6113 7547 8974 10394 11809 <br />3069 4605 6113 7547 8974 10394 11809 <br />3'-6" (42") PRECAST 2231 3069 3719 5163 6607 8054 9502 10951 <br />3069 1 4605 6113 7547 8974 10394 11809 <br />4'-0" (48") PRECAST 1966 2561 2751 3820 4890 5961 7034 8107 <br />2693 4605 6113 7547 8974 10394 11809 <br />4'-6" (54") PRECAST 1599 1969 2110 2931 3753 4576 5400 6224 <br />2189 4375 6113 7547 7 8672 10294 11809 <br />1349 1438 1999 2560 3123 3686 4249 <br />5'4" (64") PRECAST 1217 1663 1 3090 5365 1 7547 36 7342 19 8733 19 10127 19 <br />5'-10" (70") PRECAST 1062 1105 1173 1631 1 2090 2549 3009 3470 <br />1451 2622 4360 7168 e5 6036 19 7181 19 8328 20 <br />6'-6" (78") PRECAST 908 1238 2177 3480 3031 3707 4383 5061 <br />1238 2177 3480 5381 8360 10394 37 8825 14 <br />7'-6" (90") PRECAST 743 1011 1729 2632 2205 2698 3191 3685 <br />1011 1 1729 2661 3898 5681 8461 44 6472 15 <br />9'-4" (112") PRECAST 554 699 1160 1625 1 2564 3486 2818 3302 <br />752 1245 1843 2564 3486 4705 37 6390 47 <br />10'-0" (126") PRECAST 475 535 890 1247 2093 2777 2163 2536 <br />643 1052 1533 2093 2781 3643 38 4754 45 <br />11-4- (136") PRECAST 362 582 945 1366 1846 2423 3127 4006 <br />582 945 1366 1846 2423 3127 4006 <br />540 873 1254 1684 2193 2805 3552 <br />12'-0" (144") PRECAST 337 540 873 1254 1684 2193 2805 3552 <br />13'-4" (160") PRECAST 296 471 755 1075 1428 1838 2316 2883 <br />471 755 1075 1428 1838 2316 2883 <br />14'-0" (168") PRECAST 279 424 706 1002 1326 1697 2127 2630 <br />442 706 1002 1 1326 1697 2127 2630 <br />NR NR NR NR NR NR NR <br />14'-8" (176") PRESTRESSED N.R. 458 783 1370 1902 2245 2517 2712 <br />15'-4" (184") PRESTRESSED N.R. NR NR NR NR NR NR NR <br />412 710 1250 1733 2058 2320 2513 <br />17'-4" (208") PRESTRESSED N.R. NR NR NR NR NR NR NRROO 548 950 1326 1609 1849 2047 <br />19'4" (232") PRESTRESSED N.R. NR NR NR NR NR NR NR <br />235 420 750 1037 1282 1515 1716 <br />21'-4" (256") PRESTRESSED N.R. <br />NR NR NR *RNNR NR <br />180 340 598 1359 1468 <br />22'-0" (264") PRESTRESSED NR NR NR NR NR <br />N.R. 165 315 550 1285 1399 <br />NR NR NR NR NR <br />24'-0" (288") PRESTRESSED N.R. 129 250 450 1092 1222 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO.4 <br />SAFE GRAVITY LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />40 i1 *Vdw SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6-0B BRF10-0B 8RF14-0B 8RF18-0B BRF22-0B BRF26-0B 8RF30-0B <br />LENGTH 8RU6 8RF&IB 8RF10-1B 8RF14-1B 8RF18.1B 8RF^2-18 8RF26-1B 8RF30.1B <br />1749 3355 3280 4349 5421 6493 7567 <br />4'-4" (52") PRECAST 1635 18 11 3699 5206 6639 8060 9479 10893 <br />4'-6" (54") PRECAST 1494 1596 3063 2992 3968 4946 5924 6904 <br />1756 3699 5206 6639 8060 1 9479 10893 <br />5'-8" (68") PRECAST 866 920 1 1770 1716 2277 2839 3402 3966 <br />1167 2481 4567 6389 8060 34 791719 931119 <br />5'-10" (70") PRECAST 810 r85 1653 1600 2124 2649 3174 3700 <br />2342 4242 6639 10 8W 39 7402 19 8706 196'-8" (80") PRECAST 7971825 3120 5048 7747 9448 7360 <br />1825 3120 5048 7915 9479 10893 32 <br />T-6" (90") PRECAST 669 1490 2459 3776 5743 7239 5623 <br />755 1490 2459 3776 5743 80 19 10693 48 <br />9'-8" (116") PRECAST 411 466 999 1568 2253 3129 4091 3146 <br />526 999 1568 2253 3129 4150 5891 47 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO.4 <br />SAFE LATERAL LOADS FOR <br />8" PRECAST & PRESTRESSED U-LINTELS <br />SAFE LOAD <br />''"� • � PLF <br />TYPE 8U8 8F8 REINF. <br />LENGTH CMU* <br />2'-10" (34") PRECAST 1293 1642 2135 <br />T-6" (42") PRECAST 1025 1024 1830 <br />4'-0" (48") PRECAST 765 763 1365 <br />4'-6" (54") PRECAST 592 591 1057 <br />5'-4" (64") PRECAST 411 411 734 <br />5'-10" (70") PRECAST 340 339 607 <br />6'-6" (78") PRECAST 507 721 483 <br />T-6" (90") PRECAST 424 534 357 <br />9'-4" (112") PRECAST 326 512 227 <br />10'-6" (126") PRECAST 284 401 178 <br />11'4" (136") PRECAST 260 452 152 <br />12'-0" (144") PRECAST 244 402 135 <br />13'-4" (160") PRECAST 217 324 109 <br />14'-0" (168") PRECAST 205 293 98 <br />14'-8" (176") PRESTRESSED N.R. 284 89 <br />15'-4" (184") PRESTRESSED N.R. 259 82 <br />17'-4" (208") PRESTRESSED N.R. 194 63 <br />19'-4" (232") PRESTRESSED N.R. 148 51 <br />21'4" (256") PRESTRESSED N.R. 125 42 <br />22'-0" (264") PRESTRESSED N.R. 116 39 <br />24'-0" (288") PRESTRESSED N.R. 91 33 <br />* SEE NOTE 18 <br />SAFE LATERAL LOADS FOR <br />8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />SAFE LOAD <br />^-•� PLF <br />TYPE REINF. <br />LENGTH 8RU6 8RF6 CMU* <br />4'-4" (52") PRECAST 758 757 1365 <br />4'-6" (54") PRECAST 694 693 1249 <br />5'-8" (68") PRECAST 408 407 734 <br />5'-10" (70") PRECAST 382 381 687 <br />6'-8" (80") PRECAST 595 788 510 <br />T-6" (90") PRECAST 509 674 393 <br />9'-8" (116") PRECAST 370 t490 227 <br />* SEE NOTE 18 <br />SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS <br />C�~M SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8F&1T 8F121T 8F16.1T 8F201T 8F24 iT SF26 iT 8F32-iT <br />LENGTH 8F8.2T 8F12.2T 8F16-2T 8F20.2T 8F24-2T 8F28.2T 8F32-2T <br />2'-10" (34") PRECAST 1972 3173 4460 5747 7034 8321 9608 <br />1972 3173 4460 5747 7034 8321 9608 <br />3'-0" (42") PRECAST 1569 2524 3547 4569 5591 6613 7636 <br />1569 2524 3547 4569 5591 6613 7636 <br />4'-0" (48") PRECAST 1363 2192 3079 3966 4853 5740 6627 <br />1363 2192 3079 3966 4853 5740 6627 <br />4'-0" (54") PRECAST 1207 1940 2724 3508 4292 5077 5861 <br />1207 1940 2724 3508 4292 5077 5861 <br />5' 4" (64") PRECAST 1016 1632 2290 2949 3607 4265 4924 <br />1016 1632 2290 2949 3607 4265 4924 <br />5'-10" (70") PRECAST 909 1492 2093 2694 3295 3897 4498 <br />929 1492 2093 2694 3295 3897 4498 <br />6'-6" (78") PRECAST 835 12 1340 1880 2419 2959 3498 4038 <br />835 1340 1880 2419 2959 3498 4038 <br />T-6" (90") PRECAST 727 23 1021 1634 12 210411).2571 10 3039 10 3508 9 <br />727 1166 1634 2102 2571 3039 3508 <br />9'-4" (112") PRECAST 591 680 113115 147115%(15)1732 <br />16 2494 15 <br />591 851 1326 1705 3 2842 <br />10'-6" (126") PRECAST 530 552 91415 11 15 15530 686 1183 1526 4 2544 <br />11'�" (136")PRECAST474 485 79815 1034 1515 1749 15 <br />494 599 1028 1422 3 2369 <br />470 9 441 723 14 936 14 1151 15 1366 15 1582 15 <br />12'-0" (144") PRECAST 470 543 928 1349 1649 1948 2247 <br />13'-4" (160") PRECAST 41815 373 606 14 783 14 962 14 1141 14 1321 14 <br />428 455 770 1145 1444 1718 1993 <br />14'-0" (168") PRECAST 384 15 346 559 14 723 14 887 14 1052 14 1216 14 <br />410 420 709 1050 1 1434 8 1694 8 1954 7 <br />PRESTRESSED 239 323 519 13 671 13 823 13 976 14 112914 <br />14'-8" (176") 246 390 655 968 1324 8 162 11 187 11 <br />15'-4" (184") PRESTRESSED 224 302 485 13 626 13 767 13 909 13 1052 13 <br />230 364 609 897 1224 8 156214 1801 14 <br />17'-4" (208") PRESTRESSED 187 255 404 12 520 12 637 12 754 12 872 12 <br />192 303 500 732 993 8 1268 14 1470 14 <br />19'-4" (232") PRESTRESSED 162 222 34711 44611 546 12 646 12 74612 <br />166 261 424 616 831 8 105714 122514 <br />21'-4" (256") PRESTRESSED 142 198 30611 39311 48011 56711 65411 <br />142 230 369 531 713 7 903 13 1046 13 <br />22'-0" (264") PRESTRESSED 137 192 295 10 37811 461 10 54511 62911 <br />137 221 354 508 681 im <br />24'-0' (288") PRESTRESSED 124 175 267 10 341 10 416 10 <br />124 200 316 450 600 7 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS <br />FOR GR40 FIELD ADDED REBAR. SEE NOTE NO.4 <br />SAFE UPLIFT LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />4C^Vr-44 M SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6.1T 8RF10.1T 8RF14-1T 8RF18.1T 8RF22-1T 8RF26.1T 8RF30.1T <br />LENGTH 8RF6.2T 8RF10.2T 8RF14-2T 8RF18.2T 8RF22-2T 8RF26.2T 8RF30.2T <br />(52") PRECAST 905 1748 2635 3522 4409 5296 6183 <br />4 905 1748 2635 3522 4409 5296 6183 <br />4'-6" (54") PRECAST 867 1675 2525 3374 4224 5074 5924 <br />867 1 1675 2525 1 3374 4224 1 5074 5924 <br />5'-8" (68") PRECAST 675 1301 1960 2618 3277 3935 4594 <br />675 1301 1960 2618 3277 3935 4594 <br />5'-10" (70") PRECAST 655 1262 1900 2538 3176 3815 4453 <br />655 1262 1900 2538 3176 3815 4453 <br />6'-8" (80") PRECAST 570 1012 1651 2204 2758 3312 3865 <br />570 1097 1651 2204 2758 3312 3865 <br />7'-0" (90") PRECAST 506 797 1462 8 1952 7 2442 6 2931 6 3257 <br />506 967 1462 1952 t164 <br />42 2931 3421 <br />9'-8" (116") PRECAST 395 491 93112 1301 15015 198015 2322 16 <br />395 589 1135 1514 93 22 22 2652 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />e 4 s a e G <br />% po^ % <br />> D > D > D <br />0 ° 0 <br />O o <br />o Q o o b o o b o <br />8F16-1 B/0T 8F16n1 B/1T 8RF14�-1 B/OT 8FF8-11 B <br />�/ �_ / �I <br />Ho"�1% O o O <br />8F12-0B/1T <br />D Q0 o L <br />8" PRECAST LINTEL W/ Q (1#5 HOR CONT BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />�0 0 <br />C.M.U. <br />cn cn x o D <br />0- ° <br />~aw��`O <br />W U Uc #5 REBAR AT <br />�1 <br />c BOTTOM MIN. (1) <br />�Qpawz REQ'D <br />Q !� GAUGE <br />W w J Uj <br />Z-Q16 w <br />U) ILPOWERS STEEL <br />z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />:7 1-1/2" CLEAR <br />C.M.U. <br />Q <br />GROUT <br />00 <br />(.0#5 REBAR AT BOTTOM <br />OF LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8"PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) I QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />z <br />OW = <br />0 0 <br />O O <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />T p 6 2022 <br />V, A <br />LO <br />Virtual Review Assist, Inc- Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Editio <br />by Debra Anne Klahr PX2300 <br />4In <br />0 <br />Cn <br />U <br />LL 04 <br />2 <br />Lnj <br />o <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO.4 <br />SAFE GRAVITY LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />40 i1 *Vdw SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6-0B BRF10-0B 8RF14-0B 8RF18-0B BRF22-0B BRF26-0B 8RF30-0B <br />LENGTH 8RU6 8RF&IB 8RF10-1B 8RF14-1B 8RF18.1B 8RF^2-18 8RF26-1B 8RF30.1B <br />1749 3355 3280 4349 5421 6493 7567 <br />4'-4" (52") PRECAST 1635 18 11 3699 5206 6639 8060 9479 10893 <br />4'-6" (54") PRECAST 1494 1596 3063 2992 3968 4946 5924 6904 <br />1756 3699 5206 6639 8060 1 9479 10893 <br />5'-8" (68") PRECAST 866 920 1 1770 1716 2277 2839 3402 3966 <br />1167 2481 4567 6389 8060 34 791719 931119 <br />5'-10" (70") PRECAST 810 r85 1653 1600 2124 2649 3174 3700 <br />2342 4242 6639 10 8W 39 7402 19 8706 196'-8" (80") PRECAST 7971825 3120 5048 7747 9448 7360 <br />1825 3120 5048 7915 9479 10893 32 <br />T-6" (90") PRECAST 669 1490 2459 3776 5743 7239 5623 <br />755 1490 2459 3776 5743 80 19 10693 48 <br />9'-8" (116") PRECAST 411 466 999 1568 2253 3129 4091 3146 <br />526 999 1568 2253 3129 4150 5891 47 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO.4 <br />SAFE LATERAL LOADS FOR <br />8" PRECAST & PRESTRESSED U-LINTELS <br />SAFE LOAD <br />''"� • � PLF <br />TYPE 8U8 8F8 REINF. <br />LENGTH CMU* <br />2'-10" (34") PRECAST 1293 1642 2135 <br />T-6" (42") PRECAST 1025 1024 1830 <br />4'-0" (48") PRECAST 765 763 1365 <br />4'-6" (54") PRECAST 592 591 1057 <br />5'-4" (64") PRECAST 411 411 734 <br />5'-10" (70") PRECAST 340 339 607 <br />6'-6" (78") PRECAST 507 721 483 <br />T-6" (90") PRECAST 424 534 357 <br />9'-4" (112") PRECAST 326 512 227 <br />10'-6" (126") PRECAST 284 401 178 <br />11'4" (136") PRECAST 260 452 152 <br />12'-0" (144") PRECAST 244 402 135 <br />13'-4" (160") PRECAST 217 324 109 <br />14'-0" (168") PRECAST 205 293 98 <br />14'-8" (176") PRESTRESSED N.R. 284 89 <br />15'-4" (184") PRESTRESSED N.R. 259 82 <br />17'-4" (208") PRESTRESSED N.R. 194 63 <br />19'-4" (232") PRESTRESSED N.R. 148 51 <br />21'4" (256") PRESTRESSED N.R. 125 42 <br />22'-0" (264") PRESTRESSED N.R. 116 39 <br />24'-0" (288") PRESTRESSED N.R. 91 33 <br />* SEE NOTE 18 <br />SAFE LATERAL LOADS FOR <br />8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />SAFE LOAD <br />^-•� PLF <br />TYPE REINF. <br />LENGTH 8RU6 8RF6 CMU* <br />4'-4" (52") PRECAST 758 757 1365 <br />4'-6" (54") PRECAST 694 693 1249 <br />5'-8" (68") PRECAST 408 407 734 <br />5'-10" (70") PRECAST 382 381 687 <br />6'-8" (80") PRECAST 595 788 510 <br />T-6" (90") PRECAST 509 674 393 <br />9'-8" (116") PRECAST 370 t490 227 <br />* SEE NOTE 18 <br />SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS <br />C�~M SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8F&1T 8F121T 8F16.1T 8F201T 8F24 iT SF26 iT 8F32-iT <br />LENGTH 8F8.2T 8F12.2T 8F16-2T 8F20.2T 8F24-2T 8F28.2T 8F32-2T <br />2'-10" (34") PRECAST 1972 3173 4460 5747 7034 8321 9608 <br />1972 3173 4460 5747 7034 8321 9608 <br />3'-0" (42") PRECAST 1569 2524 3547 4569 5591 6613 7636 <br />1569 2524 3547 4569 5591 6613 7636 <br />4'-0" (48") PRECAST 1363 2192 3079 3966 4853 5740 6627 <br />1363 2192 3079 3966 4853 5740 6627 <br />4'-0" (54") PRECAST 1207 1940 2724 3508 4292 5077 5861 <br />1207 1940 2724 3508 4292 5077 5861 <br />5' 4" (64") PRECAST 1016 1632 2290 2949 3607 4265 4924 <br />1016 1632 2290 2949 3607 4265 4924 <br />5'-10" (70") PRECAST 909 1492 2093 2694 3295 3897 4498 <br />929 1492 2093 2694 3295 3897 4498 <br />6'-6" (78") PRECAST 835 12 1340 1880 2419 2959 3498 4038 <br />835 1340 1880 2419 2959 3498 4038 <br />T-6" (90") PRECAST 727 23 1021 1634 12 210411).2571 10 3039 10 3508 9 <br />727 1166 1634 2102 2571 3039 3508 <br />9'-4" (112") PRECAST 591 680 113115 147115%(15)1732 <br />16 2494 15 <br />591 851 1326 1705 3 2842 <br />10'-6" (126") PRECAST 530 552 91415 11 15 15530 686 1183 1526 4 2544 <br />11'�" (136")PRECAST474 485 79815 1034 1515 1749 15 <br />494 599 1028 1422 3 2369 <br />470 9 441 723 14 936 14 1151 15 1366 15 1582 15 <br />12'-0" (144") PRECAST 470 543 928 1349 1649 1948 2247 <br />13'-4" (160") PRECAST 41815 373 606 14 783 14 962 14 1141 14 1321 14 <br />428 455 770 1145 1444 1718 1993 <br />14'-0" (168") PRECAST 384 15 346 559 14 723 14 887 14 1052 14 1216 14 <br />410 420 709 1050 1 1434 8 1694 8 1954 7 <br />PRESTRESSED 239 323 519 13 671 13 823 13 976 14 112914 <br />14'-8" (176") 246 390 655 968 1324 8 162 11 187 11 <br />15'-4" (184") PRESTRESSED 224 302 485 13 626 13 767 13 909 13 1052 13 <br />230 364 609 897 1224 8 156214 1801 14 <br />17'-4" (208") PRESTRESSED 187 255 404 12 520 12 637 12 754 12 872 12 <br />192 303 500 732 993 8 1268 14 1470 14 <br />19'-4" (232") PRESTRESSED 162 222 34711 44611 546 12 646 12 74612 <br />166 261 424 616 831 8 105714 122514 <br />21'-4" (256") PRESTRESSED 142 198 30611 39311 48011 56711 65411 <br />142 230 369 531 713 7 903 13 1046 13 <br />22'-0" (264") PRESTRESSED 137 192 295 10 37811 461 10 54511 62911 <br />137 221 354 508 681 im <br />24'-0' (288") PRESTRESSED 124 175 267 10 341 10 416 10 <br />124 200 316 450 600 7 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS <br />FOR GR40 FIELD ADDED REBAR. SEE NOTE NO.4 <br />SAFE UPLIFT LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />4C^Vr-44 M SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6.1T 8RF10.1T 8RF14-1T 8RF18.1T 8RF22-1T 8RF26.1T 8RF30.1T <br />LENGTH 8RF6.2T 8RF10.2T 8RF14-2T 8RF18.2T 8RF22-2T 8RF26.2T 8RF30.2T <br />(52") PRECAST 905 1748 2635 3522 4409 5296 6183 <br />4 905 1748 2635 3522 4409 5296 6183 <br />4'-6" (54") PRECAST 867 1675 2525 3374 4224 5074 5924 <br />867 1 1675 2525 1 3374 4224 1 5074 5924 <br />5'-8" (68") PRECAST 675 1301 1960 2618 3277 3935 4594 <br />675 1301 1960 2618 3277 3935 4594 <br />5'-10" (70") PRECAST 655 1262 1900 2538 3176 3815 4453 <br />655 1262 1900 2538 3176 3815 4453 <br />6'-8" (80") PRECAST 570 1012 1651 2204 2758 3312 3865 <br />570 1097 1651 2204 2758 3312 3865 <br />7'-0" (90") PRECAST 506 797 1462 8 1952 7 2442 6 2931 6 3257 <br />506 967 1462 1952 t164 <br />42 2931 3421 <br />9'-8" (116") PRECAST 395 491 93112 1301 15015 198015 2322 16 <br />395 589 1135 1514 93 22 22 2652 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />e 4 s a e G <br />% po^ % <br />> D > D > D <br />0 ° 0 <br />O o <br />o Q o o b o o b o <br />8F16-1 B/0T 8F16n1 B/1T 8RF14�-1 B/OT 8FF8-11 B <br />�/ �_ / �I <br />Ho"�1% O o O <br />8F12-0B/1T <br />D Q0 o L <br />8" PRECAST LINTEL W/ Q (1#5 HOR CONT BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />�0 0 <br />C.M.U. <br />cn cn x o D <br />0- ° <br />~aw��`O <br />W U Uc #5 REBAR AT <br />�1 <br />c BOTTOM MIN. (1) <br />�Qpawz REQ'D <br />Q !� GAUGE <br />W w J Uj <br />Z-Q16 w <br />U) ILPOWERS STEEL <br />z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />:7 1-1/2" CLEAR <br />C.M.U. <br />Q <br />GROUT <br />00 <br />(.0#5 REBAR AT BOTTOM <br />OF LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8"PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) I QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />z <br />OW = <br />0 0 <br />O O <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />T p 6 2022 <br />V, A <br />LO <br />Virtual Review Assist, Inc- Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Editio <br />by Debra Anne Klahr PX2300 <br />4In <br />0 <br />Cn <br />U <br />LL 04 <br />2 <br />Lnj <br />o <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO.4 <br />SAFE LATERAL LOADS FOR <br />8" PRECAST & PRESTRESSED U-LINTELS <br />SAFE LOAD <br />''"� • � PLF <br />TYPE 8U8 8F8 REINF. <br />LENGTH CMU* <br />2'-10" (34") PRECAST 1293 1642 2135 <br />T-6" (42") PRECAST 1025 1024 1830 <br />4'-0" (48") PRECAST 765 763 1365 <br />4'-6" (54") PRECAST 592 591 1057 <br />5'-4" (64") PRECAST 411 411 734 <br />5'-10" (70") PRECAST 340 339 607 <br />6'-6" (78") PRECAST 507 721 483 <br />T-6" (90") PRECAST 424 534 357 <br />9'-4" (112") PRECAST 326 512 227 <br />10'-6" (126") PRECAST 284 401 178 <br />11'4" (136") PRECAST 260 452 152 <br />12'-0" (144") PRECAST 244 402 135 <br />13'-4" (160") PRECAST 217 324 109 <br />14'-0" (168") PRECAST 205 293 98 <br />14'-8" (176") PRESTRESSED N.R. 284 89 <br />15'-4" (184") PRESTRESSED N.R. 259 82 <br />17'-4" (208") PRESTRESSED N.R. 194 63 <br />19'-4" (232") PRESTRESSED N.R. 148 51 <br />21'4" (256") PRESTRESSED N.R. 125 42 <br />22'-0" (264") PRESTRESSED N.R. 116 39 <br />24'-0" (288") PRESTRESSED N.R. 91 33 <br />* SEE NOTE 18 <br />SAFE LATERAL LOADS FOR <br />8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />SAFE LOAD <br />^-•� PLF <br />TYPE REINF. <br />LENGTH 8RU6 8RF6 CMU* <br />4'-4" (52") PRECAST 758 757 1365 <br />4'-6" (54") PRECAST 694 693 1249 <br />5'-8" (68") PRECAST 408 407 734 <br />5'-10" (70") PRECAST 382 381 687 <br />6'-8" (80") PRECAST 595 788 510 <br />T-6" (90") PRECAST 509 674 393 <br />9'-8" (116") PRECAST 370 t490 227 <br />* SEE NOTE 18 <br />SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS <br />C�~M SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8F&1T 8F121T 8F16.1T 8F201T 8F24 iT SF26 iT 8F32-iT <br />LENGTH 8F8.2T 8F12.2T 8F16-2T 8F20.2T 8F24-2T 8F28.2T 8F32-2T <br />2'-10" (34") PRECAST 1972 3173 4460 5747 7034 8321 9608 <br />1972 3173 4460 5747 7034 8321 9608 <br />3'-0" (42") PRECAST 1569 2524 3547 4569 5591 6613 7636 <br />1569 2524 3547 4569 5591 6613 7636 <br />4'-0" (48") PRECAST 1363 2192 3079 3966 4853 5740 6627 <br />1363 2192 3079 3966 4853 5740 6627 <br />4'-0" (54") PRECAST 1207 1940 2724 3508 4292 5077 5861 <br />1207 1940 2724 3508 4292 5077 5861 <br />5' 4" (64") PRECAST 1016 1632 2290 2949 3607 4265 4924 <br />1016 1632 2290 2949 3607 4265 4924 <br />5'-10" (70") PRECAST 909 1492 2093 2694 3295 3897 4498 <br />929 1492 2093 2694 3295 3897 4498 <br />6'-6" (78") PRECAST 835 12 1340 1880 2419 2959 3498 4038 <br />835 1340 1880 2419 2959 3498 4038 <br />T-6" (90") PRECAST 727 23 1021 1634 12 210411).2571 10 3039 10 3508 9 <br />727 1166 1634 2102 2571 3039 3508 <br />9'-4" (112") PRECAST 591 680 113115 147115%(15)1732 <br />16 2494 15 <br />591 851 1326 1705 3 2842 <br />10'-6" (126") PRECAST 530 552 91415 11 15 15530 686 1183 1526 4 2544 <br />11'�" (136")PRECAST474 485 79815 1034 1515 1749 15 <br />494 599 1028 1422 3 2369 <br />470 9 441 723 14 936 14 1151 15 1366 15 1582 15 <br />12'-0" (144") PRECAST 470 543 928 1349 1649 1948 2247 <br />13'-4" (160") PRECAST 41815 373 606 14 783 14 962 14 1141 14 1321 14 <br />428 455 770 1145 1444 1718 1993 <br />14'-0" (168") PRECAST 384 15 346 559 14 723 14 887 14 1052 14 1216 14 <br />410 420 709 1050 1 1434 8 1694 8 1954 7 <br />PRESTRESSED 239 323 519 13 671 13 823 13 976 14 112914 <br />14'-8" (176") 246 390 655 968 1324 8 162 11 187 11 <br />15'-4" (184") PRESTRESSED 224 302 485 13 626 13 767 13 909 13 1052 13 <br />230 364 609 897 1224 8 156214 1801 14 <br />17'-4" (208") PRESTRESSED 187 255 404 12 520 12 637 12 754 12 872 12 <br />192 303 500 732 993 8 1268 14 1470 14 <br />19'-4" (232") PRESTRESSED 162 222 34711 44611 546 12 646 12 74612 <br />166 261 424 616 831 8 105714 122514 <br />21'-4" (256") PRESTRESSED 142 198 30611 39311 48011 56711 65411 <br />142 230 369 531 713 7 903 13 1046 13 <br />22'-0" (264") PRESTRESSED 137 192 295 10 37811 461 10 54511 62911 <br />137 221 354 508 681 im <br />24'-0' (288") PRESTRESSED 124 175 267 10 341 10 416 10 <br />124 200 316 450 600 7 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS <br />FOR GR40 FIELD ADDED REBAR. SEE NOTE NO.4 <br />SAFE UPLIFT LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />4C^Vr-44 M SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6.1T 8RF10.1T 8RF14-1T 8RF18.1T 8RF22-1T 8RF26.1T 8RF30.1T <br />LENGTH 8RF6.2T 8RF10.2T 8RF14-2T 8RF18.2T 8RF22-2T 8RF26.2T 8RF30.2T <br />(52") PRECAST 905 1748 2635 3522 4409 5296 6183 <br />4 905 1748 2635 3522 4409 5296 6183 <br />4'-6" (54") PRECAST 867 1675 2525 3374 4224 5074 5924 <br />867 1 1675 2525 1 3374 4224 1 5074 5924 <br />5'-8" (68") PRECAST 675 1301 1960 2618 3277 3935 4594 <br />675 1301 1960 2618 3277 3935 4594 <br />5'-10" (70") PRECAST 655 1262 1900 2538 3176 3815 4453 <br />655 1262 1900 2538 3176 3815 4453 <br />6'-8" (80") PRECAST 570 1012 1651 2204 2758 3312 3865 <br />570 1097 1651 2204 2758 3312 3865 <br />7'-0" (90") PRECAST 506 797 1462 8 1952 7 2442 6 2931 6 3257 <br />506 967 1462 1952 t164 <br />42 2931 3421 <br />9'-8" (116") PRECAST 395 491 93112 1301 15015 198015 2322 16 <br />395 589 1135 1514 93 22 22 2652 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />e 4 s a e G <br />% po^ % <br />> D > D > D <br />0 ° 0 <br />O o <br />o Q o o b o o b o <br />8F16-1 B/0T 8F16n1 B/1T 8RF14�-1 B/OT 8FF8-11 B <br />�/ �_ / �I <br />Ho"�1% O o O <br />8F12-0B/1T <br />D Q0 o L <br />8" PRECAST LINTEL W/ Q (1#5 HOR CONT BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />�0 0 <br />C.M.U. <br />cn cn x o D <br />0- ° <br />~aw��`O <br />W U Uc #5 REBAR AT <br />�1 <br />c BOTTOM MIN. (1) <br />�Qpawz REQ'D <br />Q !� GAUGE <br />W w J Uj <br />Z-Q16 w <br />U) ILPOWERS STEEL <br />z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />:7 1-1/2" CLEAR <br />C.M.U. <br />Q <br />GROUT <br />00 <br />(.0#5 REBAR AT BOTTOM <br />OF LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8"PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) I QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />z <br />OW = <br />0 0 <br />O O <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />T p 6 2022 <br />V, A <br />LO <br />Virtual Review Assist, Inc- Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Editio <br />by Debra Anne Klahr PX2300 <br />4In <br />0 <br />Cn <br />U <br />LL 04 <br />2 <br />Lnj <br />o <br />* SEE NOTE 18 <br />SAFE LATERAL LOADS FOR <br />8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />SAFE LOAD <br />^-•� PLF <br />TYPE REINF. <br />LENGTH 8RU6 8RF6 CMU* <br />4'-4" (52") PRECAST 758 757 1365 <br />4'-6" (54") PRECAST 694 693 1249 <br />5'-8" (68") PRECAST 408 407 734 <br />5'-10" (70") PRECAST 382 381 687 <br />6'-8" (80") PRECAST 595 788 510 <br />T-6" (90") PRECAST 509 674 393 <br />9'-8" (116") PRECAST 370 t490 227 <br />* SEE NOTE 18 <br />SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS <br />C�~M SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8F&1T 8F121T 8F16.1T 8F201T 8F24 iT SF26 iT 8F32-iT <br />LENGTH 8F8.2T 8F12.2T 8F16-2T 8F20.2T 8F24-2T 8F28.2T 8F32-2T <br />2'-10" (34") PRECAST 1972 3173 4460 5747 7034 8321 9608 <br />1972 3173 4460 5747 7034 8321 9608 <br />3'-0" (42") PRECAST 1569 2524 3547 4569 5591 6613 7636 <br />1569 2524 3547 4569 5591 6613 7636 <br />4'-0" (48") PRECAST 1363 2192 3079 3966 4853 5740 6627 <br />1363 2192 3079 3966 4853 5740 6627 <br />4'-0" (54") PRECAST 1207 1940 2724 3508 4292 5077 5861 <br />1207 1940 2724 3508 4292 5077 5861 <br />5' 4" (64") PRECAST 1016 1632 2290 2949 3607 4265 4924 <br />1016 1632 2290 2949 3607 4265 4924 <br />5'-10" (70") PRECAST 909 1492 2093 2694 3295 3897 4498 <br />929 1492 2093 2694 3295 3897 4498 <br />6'-6" (78") PRECAST 835 12 1340 1880 2419 2959 3498 4038 <br />835 1340 1880 2419 2959 3498 4038 <br />T-6" (90") PRECAST 727 23 1021 1634 12 210411).2571 10 3039 10 3508 9 <br />727 1166 1634 2102 2571 3039 3508 <br />9'-4" (112") PRECAST 591 680 113115 147115%(15)1732 <br />16 2494 15 <br />591 851 1326 1705 3 2842 <br />10'-6" (126") PRECAST 530 552 91415 11 15 15530 686 1183 1526 4 2544 <br />11'�" (136")PRECAST474 485 79815 1034 1515 1749 15 <br />494 599 1028 1422 3 2369 <br />470 9 441 723 14 936 14 1151 15 1366 15 1582 15 <br />12'-0" (144") PRECAST 470 543 928 1349 1649 1948 2247 <br />13'-4" (160") PRECAST 41815 373 606 14 783 14 962 14 1141 14 1321 14 <br />428 455 770 1145 1444 1718 1993 <br />14'-0" (168") PRECAST 384 15 346 559 14 723 14 887 14 1052 14 1216 14 <br />410 420 709 1050 1 1434 8 1694 8 1954 7 <br />PRESTRESSED 239 323 519 13 671 13 823 13 976 14 112914 <br />14'-8" (176") 246 390 655 968 1324 8 162 11 187 11 <br />15'-4" (184") PRESTRESSED 224 302 485 13 626 13 767 13 909 13 1052 13 <br />230 364 609 897 1224 8 156214 1801 14 <br />17'-4" (208") PRESTRESSED 187 255 404 12 520 12 637 12 754 12 872 12 <br />192 303 500 732 993 8 1268 14 1470 14 <br />19'-4" (232") PRESTRESSED 162 222 34711 44611 546 12 646 12 74612 <br />166 261 424 616 831 8 105714 122514 <br />21'-4" (256") PRESTRESSED 142 198 30611 39311 48011 56711 65411 <br />142 230 369 531 713 7 903 13 1046 13 <br />22'-0" (264") PRESTRESSED 137 192 295 10 37811 461 10 54511 62911 <br />137 221 354 508 681 im <br />24'-0' (288") PRESTRESSED 124 175 267 10 341 10 416 10 <br />124 200 316 450 600 7 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS <br />FOR GR40 FIELD ADDED REBAR. SEE NOTE NO.4 <br />SAFE UPLIFT LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />4C^Vr-44 M SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6.1T 8RF10.1T 8RF14-1T 8RF18.1T 8RF22-1T 8RF26.1T 8RF30.1T <br />LENGTH 8RF6.2T 8RF10.2T 8RF14-2T 8RF18.2T 8RF22-2T 8RF26.2T 8RF30.2T <br />(52") PRECAST 905 1748 2635 3522 4409 5296 6183 <br />4 905 1748 2635 3522 4409 5296 6183 <br />4'-6" (54") PRECAST 867 1675 2525 3374 4224 5074 5924 <br />867 1 1675 2525 1 3374 4224 1 5074 5924 <br />5'-8" (68") PRECAST 675 1301 1960 2618 3277 3935 4594 <br />675 1301 1960 2618 3277 3935 4594 <br />5'-10" (70") PRECAST 655 1262 1900 2538 3176 3815 4453 <br />655 1262 1900 2538 3176 3815 4453 <br />6'-8" (80") PRECAST 570 1012 1651 2204 2758 3312 3865 <br />570 1097 1651 2204 2758 3312 3865 <br />7'-0" (90") PRECAST 506 797 1462 8 1952 7 2442 6 2931 6 3257 <br />506 967 1462 1952 t164 <br />42 2931 3421 <br />9'-8" (116") PRECAST 395 491 93112 1301 15015 198015 2322 16 <br />395 589 1135 1514 93 22 22 2652 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />e 4 s a e G <br />% po^ % <br />> D > D > D <br />0 ° 0 <br />O o <br />o Q o o b o o b o <br />8F16-1 B/0T 8F16n1 B/1T 8RF14�-1 B/OT 8FF8-11 B <br />�/ �_ / �I <br />Ho"�1% O o O <br />8F12-0B/1T <br />D Q0 o L <br />8" PRECAST LINTEL W/ Q (1#5 HOR CONT BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />�0 0 <br />C.M.U. <br />cn cn x o D <br />0- ° <br />~aw��`O <br />W U Uc #5 REBAR AT <br />�1 <br />c BOTTOM MIN. (1) <br />�Qpawz REQ'D <br />Q !� GAUGE <br />W w J Uj <br />Z-Q16 w <br />U) ILPOWERS STEEL <br />z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />:7 1-1/2" CLEAR <br />C.M.U. <br />Q <br />GROUT <br />00 <br />(.0#5 REBAR AT BOTTOM <br />OF LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8"PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) I QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />z <br />OW = <br />0 0 <br />O O <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />T p 6 2022 <br />V, A <br />LO <br />Virtual Review Assist, Inc- Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Editio <br />by Debra Anne Klahr PX2300 <br />4In <br />0 <br />Cn <br />U <br />LL 04 <br />2 <br />Lnj <br />o <br />* SEE NOTE 18 <br />SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS <br />C�~M SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8F&1T 8F121T 8F16.1T 8F201T 8F24 iT SF26 iT 8F32-iT <br />LENGTH 8F8.2T 8F12.2T 8F16-2T 8F20.2T 8F24-2T 8F28.2T 8F32-2T <br />2'-10" (34") PRECAST 1972 3173 4460 5747 7034 8321 9608 <br />1972 3173 4460 5747 7034 8321 9608 <br />3'-0" (42") PRECAST 1569 2524 3547 4569 5591 6613 7636 <br />1569 2524 3547 4569 5591 6613 7636 <br />4'-0" (48") PRECAST 1363 2192 3079 3966 4853 5740 6627 <br />1363 2192 3079 3966 4853 5740 6627 <br />4'-0" (54") PRECAST 1207 1940 2724 3508 4292 5077 5861 <br />1207 1940 2724 3508 4292 5077 5861 <br />5' 4" (64") PRECAST 1016 1632 2290 2949 3607 4265 4924 <br />1016 1632 2290 2949 3607 4265 4924 <br />5'-10" (70") PRECAST 909 1492 2093 2694 3295 3897 4498 <br />929 1492 2093 2694 3295 3897 4498 <br />6'-6" (78") PRECAST 835 12 1340 1880 2419 2959 3498 4038 <br />835 1340 1880 2419 2959 3498 4038 <br />T-6" (90") PRECAST 727 23 1021 1634 12 210411).2571 10 3039 10 3508 9 <br />727 1166 1634 2102 2571 3039 3508 <br />9'-4" (112") PRECAST 591 680 113115 147115%(15)1732 <br />16 2494 15 <br />591 851 1326 1705 3 2842 <br />10'-6" (126") PRECAST 530 552 91415 11 15 15530 686 1183 1526 4 2544 <br />11'�" (136")PRECAST474 485 79815 1034 1515 1749 15 <br />494 599 1028 1422 3 2369 <br />470 9 441 723 14 936 14 1151 15 1366 15 1582 15 <br />12'-0" (144") PRECAST 470 543 928 1349 1649 1948 2247 <br />13'-4" (160") PRECAST 41815 373 606 14 783 14 962 14 1141 14 1321 14 <br />428 455 770 1145 1444 1718 1993 <br />14'-0" (168") PRECAST 384 15 346 559 14 723 14 887 14 1052 14 1216 14 <br />410 420 709 1050 1 1434 8 1694 8 1954 7 <br />PRESTRESSED 239 323 519 13 671 13 823 13 976 14 112914 <br />14'-8" (176") 246 390 655 968 1324 8 162 11 187 11 <br />15'-4" (184") PRESTRESSED 224 302 485 13 626 13 767 13 909 13 1052 13 <br />230 364 609 897 1224 8 156214 1801 14 <br />17'-4" (208") PRESTRESSED 187 255 404 12 520 12 637 12 754 12 872 12 <br />192 303 500 732 993 8 1268 14 1470 14 <br />19'-4" (232") PRESTRESSED 162 222 34711 44611 546 12 646 12 74612 <br />166 261 424 616 831 8 105714 122514 <br />21'-4" (256") PRESTRESSED 142 198 30611 39311 48011 56711 65411 <br />142 230 369 531 713 7 903 13 1046 13 <br />22'-0" (264") PRESTRESSED 137 192 295 10 37811 461 10 54511 62911 <br />137 221 354 508 681 im <br />24'-0' (288") PRESTRESSED 124 175 267 10 341 10 416 10 <br />124 200 316 450 600 7 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS <br />FOR GR40 FIELD ADDED REBAR. SEE NOTE NO.4 <br />SAFE UPLIFT LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />4C^Vr-44 M SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6.1T 8RF10.1T 8RF14-1T 8RF18.1T 8RF22-1T 8RF26.1T 8RF30.1T <br />LENGTH 8RF6.2T 8RF10.2T 8RF14-2T 8RF18.2T 8RF22-2T 8RF26.2T 8RF30.2T <br />(52") PRECAST 905 1748 2635 3522 4409 5296 6183 <br />4 905 1748 2635 3522 4409 5296 6183 <br />4'-6" (54") PRECAST 867 1675 2525 3374 4224 5074 5924 <br />867 1 1675 2525 1 3374 4224 1 5074 5924 <br />5'-8" (68") PRECAST 675 1301 1960 2618 3277 3935 4594 <br />675 1301 1960 2618 3277 3935 4594 <br />5'-10" (70") PRECAST 655 1262 1900 2538 3176 3815 4453 <br />655 1262 1900 2538 3176 3815 4453 <br />6'-8" (80") PRECAST 570 1012 1651 2204 2758 3312 3865 <br />570 1097 1651 2204 2758 3312 3865 <br />7'-0" (90") PRECAST 506 797 1462 8 1952 7 2442 6 2931 6 3257 <br />506 967 1462 1952 t164 <br />42 2931 3421 <br />9'-8" (116") PRECAST 395 491 93112 1301 15015 198015 2322 16 <br />395 589 1135 1514 93 22 22 2652 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />e 4 s a e G <br />% po^ % <br />> D > D > D <br />0 ° 0 <br />O o <br />o Q o o b o o b o <br />8F16-1 B/0T 8F16n1 B/1T 8RF14�-1 B/OT 8FF8-11 B <br />�/ �_ / �I <br />Ho"�1% O o O <br />8F12-0B/1T <br />D Q0 o L <br />8" PRECAST LINTEL W/ Q (1#5 HOR CONT BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />�0 0 <br />C.M.U. <br />cn cn x o D <br />0- ° <br />~aw��`O <br />W U Uc #5 REBAR AT <br />�1 <br />c BOTTOM MIN. (1) <br />�Qpawz REQ'D <br />Q !� GAUGE <br />W w J Uj <br />Z-Q16 w <br />U) ILPOWERS STEEL <br />z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />:7 1-1/2" CLEAR <br />C.M.U. <br />Q <br />GROUT <br />00 <br />(.0#5 REBAR AT BOTTOM <br />OF LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8"PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) I QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />z <br />OW = <br />0 0 <br />O O <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />T p 6 2022 <br />V, A <br />LO <br />Virtual Review Assist, Inc- Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Editio <br />by Debra Anne Klahr PX2300 <br />4In <br />0 <br />Cn <br />U <br />LL 04 <br />2 <br />Lnj <br />o <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS <br />FOR GR40 FIELD ADDED REBAR. SEE NOTE NO.4 <br />SAFE UPLIFT LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />4C^Vr-44 M SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6.1T 8RF10.1T 8RF14-1T 8RF18.1T 8RF22-1T 8RF26.1T 8RF30.1T <br />LENGTH 8RF6.2T 8RF10.2T 8RF14-2T 8RF18.2T 8RF22-2T 8RF26.2T 8RF30.2T <br />(52") PRECAST 905 1748 2635 3522 4409 5296 6183 <br />4 905 1748 2635 3522 4409 5296 6183 <br />4'-6" (54") PRECAST 867 1675 2525 3374 4224 5074 5924 <br />867 1 1675 2525 1 3374 4224 1 5074 5924 <br />5'-8" (68") PRECAST 675 1301 1960 2618 3277 3935 4594 <br />675 1301 1960 2618 3277 3935 4594 <br />5'-10" (70") PRECAST 655 1262 1900 2538 3176 3815 4453 <br />655 1262 1900 2538 3176 3815 4453 <br />6'-8" (80") PRECAST 570 1012 1651 2204 2758 3312 3865 <br />570 1097 1651 2204 2758 3312 3865 <br />7'-0" (90") PRECAST 506 797 1462 8 1952 7 2442 6 2931 6 3257 <br />506 967 1462 1952 t164 <br />42 2931 3421 <br />9'-8" (116") PRECAST 395 491 93112 1301 15015 198015 2322 16 <br />395 589 1135 1514 93 22 22 2652 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />e 4 s a e G <br />% po^ % <br />> D > D > D <br />0 ° 0 <br />O o <br />o Q o o b o o b o <br />8F16-1 B/0T 8F16n1 B/1T 8RF14�-1 B/OT 8FF8-11 B <br />�/ �_ / �I <br />Ho"�1% O o O <br />8F12-0B/1T <br />D Q0 o L <br />8" PRECAST LINTEL W/ Q (1#5 HOR CONT BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />�0 0 <br />C.M.U. <br />cn cn x o D <br />0- ° <br />~aw��`O <br />W U Uc #5 REBAR AT <br />�1 <br />c BOTTOM MIN. (1) <br />�Qpawz REQ'D <br />Q !� GAUGE <br />W w J Uj <br />Z-Q16 w <br />U) ILPOWERS STEEL <br />z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />:7 1-1/2" CLEAR <br />C.M.U. <br />Q <br />GROUT <br />00 <br />(.0#5 REBAR AT BOTTOM <br />OF LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8"PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) I QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />z <br />OW = <br />0 0 <br />O O <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />T p 6 2022 <br />V, A <br />LO <br />Virtual Review Assist, Inc- Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Editio <br />by Debra Anne Klahr PX2300 <br />4In <br />0 <br />Cn <br />U <br />LL 04 <br />2 <br />Lnj <br />o <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />e 4 s a e G <br />% po^ % <br />> D > D > D <br />0 ° 0 <br />O o <br />o Q o o b o o b o <br />8F16-1 B/0T 8F16n1 B/1T 8RF14�-1 B/OT 8FF8-11 B <br />�/ �_ / �I <br />Ho"�1% O o O <br />8F12-0B/1T <br />D Q0 o L <br />8" PRECAST LINTEL W/ Q (1#5 HOR CONT BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />�0 0 <br />C.M.U. <br />cn cn x o D <br />0- ° <br />~aw��`O <br />W U Uc #5 REBAR AT <br />�1 <br />c BOTTOM MIN. (1) <br />�Qpawz REQ'D <br />Q !� GAUGE <br />W w J Uj <br />Z-Q16 w <br />U) ILPOWERS STEEL <br />z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />:7 1-1/2" CLEAR <br />C.M.U. <br />Q <br />GROUT <br />00 <br />(.0#5 REBAR AT BOTTOM <br />OF LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8"PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) I QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />z <br />OW = <br />0 0 <br />O O <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />T p 6 2022 <br />V, A <br />LO <br />Virtual Review Assist, Inc- Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Editio <br />by Debra Anne Klahr PX2300 <br />4In <br />0 <br />Cn <br />U <br />LL 04 <br />2 <br />Lnj <br />o <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />�0 0 <br />C.M.U. <br />cn cn x o D <br />0- ° <br />~aw��`O <br />W U Uc #5 REBAR AT <br />�1 <br />c BOTTOM MIN. (1) <br />�Qpawz REQ'D <br />Q !� GAUGE <br />W w J Uj <br />Z-Q16 w <br />U) ILPOWERS STEEL <br />z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />:7 1-1/2" CLEAR <br />C.M.U. <br />Q <br />GROUT <br />00 <br />(.0#5 REBAR AT BOTTOM <br />OF LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8"PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) I QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />z <br />OW = <br />0 0 <br />O O <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />T p 6 2022 <br />V, A <br />LO <br />Virtual Review Assist, Inc- Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Editio <br />by Debra Anne Klahr PX2300 <br />4In <br />0 <br />Cn <br />U <br />LL 04 <br />2 <br />Lnj <br />o <br />O O <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />T p 6 2022 <br />V, A <br />LO <br />Virtual Review Assist, Inc- Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Editio <br />by Debra Anne Klahr PX2300 <br />4In <br />0 <br />Cn <br />U <br />LL 04 <br />2 <br />Lnj <br />o <br />N <br />N <br />O <br />N <br />N <br />Q <br />Z <br />Q <br />^, <br />N n E <br />br~2 <br />L U <br />W 'i <br />� N <br />