ROOF FINISH <br />PER ELEVATION <br />ROOF SHEATHING <br />MANUFACTURED <br />ROOFTRUSS <br />MTL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />67 <br />SOFFIT DETAIL <br />ROOF FINISH <br />PER ELEVATION <br />ROOF SHEATHING <br />12 <br />5 MANUFACTURED <br />ROOF TRUSS <br />' MTL DRIP EDGE <br />ro: <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />SOFFIT DETAIL <br />7 <br />CV <br />o <br />CV N <br />tV <br />FALSE FOAM LOUVERDETAIL <br />TYP <br />8 <br />1'-4" <br />1' 1" <br />1'-2"— — — — — — — — — — <br />(V <br />is <br />i� <br />ca <br />12" SQ CMU COLUMN, <br />SMOOTH STUCCO <br />FINISH <br />STUCCO BAND <br />io <br />LV <br />DETAIL <br />D9COLUMN <br />If <br />PROVIDE FILLED SOLID <br />CMU ABOVE LINTEL TO <br />TIE BEAM <br />FLASHING <br />CASING BEAD WITH WEEP HOLE <br />PT 2X8 LEDGER ATTACHED TO <br />WALL W/ 3/8" X 5" TITEN HD AT <br />12" O.C. STAGGERED <br />(S)H10A-2 <br />ROOF FINISH PER ELEVATION <br />UNDERLAYMENT <br />ELEV AT 8'-0" <br />12 T.O.M. <br />—15 <br />ROOF SHEATHING <br />(S)A23 <br />E---MTL DRIP EDGE <br />2X4 SUB -FASCIA <br />•'' 2'-0" ALUMINUM WRAP <br />(S) A23 ALUMINUM SOFFIT <br />PT 2X4 LEDGER ATTACHED TO <br />WALL W/ 3116" TAPCONS W/ <br />MIN 2-1/2" EMBEDMENT 6" O.C. <br />BTM AT T-6" <br />710 SOFFIT DETAIL <br />PT 2X8 LEDGER ATTACHED TO WALL <br />W/ 3/8" X 5" TITEN HD AT 12" O.C. <br />STAGGERED <br />(V <br />D 0 0 <br />o <br />LEDGER DETAIL <br />11 a = 1 1-ni, <br />CASING BEAD <br />WITH WEEP HOLES <br />OVER FLASHING — <br />ELEV AT 8'-8" <br />T.O.M. <br />ELEV AT 0'-0" _ <br />1ST FLOOR FF <br />FRONT ELEVATION A <br />1 /411 = 1'-0„ <br />8" TRUSS HEEL <br />ELEV AT 18'-0" <br />T.O.P. <br />1'-0'* <br />ELEV AT 10'-0" <br />2ND FLOOR FF <br />ELEV AT 8'-8" <br />T.O.M. <br />MID WALL <br />WEEP SCREED <br />5/8" STUCCO <br />OVER <br />MASONRY_______t <br />ELEV AT 0'-0" <br />12 <br />51 _, <br />7/8" STUCCO <br />rOVER FRAME 'e <br />CONTROL JOINT — <br />1 ST FLOOR FF <br />GRADE LINE <br />DREAR ELEVATION A <br />1/ <br />/8 - 1-0 <br />8" TRUSS <br />ELEV AT 18'-0" <br />T.O.P. <br />ELEV AT 8'-8" <br />T.O.M. <br />ELEV AT 0'-0" <br />1 ST FLOOR FF <br />8" TRUSS HEEL <br />ELEV AT 18'-0" <br />T.O.P. <br />ELEV AT 10'-0" <br />2ND FLOOR FF <br />GRADE LINE---/ <br />RIGHT ELEVATION A <br />1 /811 = 1'-011 <br />12 <br />51 <br />16'-8" % <br />7/8" STUCCO J <br />OVER FRAME <br />CONTROL JOINT <br />ELEV AT 8'-8" <br />T.O.M. <br />A/C UNIT 2'-0" <br />AND PAD co <br />r <br />ELEV AT 0'-0" <br />MID WALL J <br />WEEP SCREED <br />1ST FLOOR FF <br />GRADE LINE <br />CLEFT ELEVATION A <br />ININ - - - -■ <br />INININININININI <br />INJI �ININININI <br />10101MININNIMIMI-. <br />A/C UNIT <br />AND PAD <br />I- <br />18'-8" _ <br />C� — <br />M oW <br />1 /811 = 1 1-011 <br />16'-8" <br />CONTROL JOINT — <br />5/8" STUCCO <br />OVER - <br />�MASONRY <br />n <br />I A-6" <br />1'-0" <br />A/C UN <br />,AND P/ <br />4" STUCCO <br />BAND <br />6" STUCCO <br />BAND <br />WEEP <br />SCREED <br />,-O„ <br />4" STUCCO <br />BAND <br />5/8" <br />STUCCO <br />OVER <br />MASONRY <br />0- -- <br />5:12 <br />1 ROOF PLAN A <br />1 /8if= 11-011 <br />0 <br />I <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM)) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />\1 AIL <br />Virtual Review Assist, Inc. <br />Plans Review completed and appr�t <br />ROOF GENERAL NOT : by Debra Anne Klahr PX230 <br />* G.C. VERIFY ROOF PITCH <br />ROOF PITCH VARIES PER SUBDIVISIONS (5/12 PR 5.9/12) <br />IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF <br />SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. <br />ROOF CRITERIA <br />- 12" OVERHANG U.N.O. <br />- PLUMB CUT FASCIA <br />- ROOF PITCH PER ELEVATION <br />- WINDLOAD CALC. PER ASCE 7-98 (VARIES BY LOCATION) <br />- SHINGLE LOADING <br />ROOF VENT CALCULATIONS: <br />NOTE: VERIFY WITH GENERAL CONTRACTOR ALL ROOF VENT <br />LOCATIONS, QUANTITIES, AND SIZES. ROOF VENTS SHALL BE <br />INSTALLED FOR A MIN. OF VENTED AREA AS LISTED BELOW OR <br />EQUIVALENT SYSTEM PER 7TH EDITION (2020) FBC, SECTION R806 <br />FORMULA = S.F. / 300 (1/300) * 144 (TO CONVERT TO SQ. INCHES) _ <br />NET SQ. INCH REQUIREMENT <br />ATTIC AREA 1 = 1268 SQ FT <br />VENTILATION REQUIRED = 609 SQ IN <br />VENTILATION PROVIDED AT RIDGE = 306 SQ IN <br />VENTILATION PROVIDED AT SOFFIT =1204 SQ IN <br />ATTIC AREA 2 = 466 SQ FT <br />VENTILATION REQUIRED = 224 SQ IN <br />VENTILATION PROVIDED AT RIDGE = 126 SQ IN <br />VENTILATION PROVIDED AT SOFFIT =399 SQ IN <br />ATTIC VENTILATION <br />ATTIC VENTILATION TO BE IN COMPLIANCE WITH THE FLORIDA <br />BUILDING CODE 7TH EDITION (202TO RESIDENTIAL R806. <br />THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OF THE <br />AREA OF THE VENTED SPACE. THE VENTILATED AREA MAY BE <br />REDUCED TO 11300 PROVIDED THAT AT LEAST 40% BUT NO MORE <br />THAN 50% OF THE REQUIRED VENTILATION IS PROVIDED IN THE <br />UPPER PORTION OF THE SPACE TO BE VENTILATED. UPPER <br />VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET MEASURE <br />VERTICALLY) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, <br />WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY <br />EAVE OR CORNICE VENTS. <br />CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN. <br />VALUES TO BE VERIFIED WITH MANUFACTURER SPECIFICATIONS) <br />RIDGE VENTS - 18 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />* OFF -RIDGE VENTS - 138 SQ. IN. OF NET FREE AREA / UNIT <br />* SOFFIT VENTS - 7 SQ. IN. OF THE NET FREE AREA / SO. FT. <br />IF NOT ENOUGH VENTED SOFFIT IS PROVIDED DUE TO FIRE <br />PROTECTION. THE CONTRACTOR SHALL USE DECK -AIR OF OTHER <br />APPROVED MATERIAL TO PROVIDE SUFFICIENT IN -TAKE VENTILATION <br />* LOMANCO DECK -AIR - 9 SQ. IN. OF NET FREE AREA / FT. FOR SHINGLE <br />36 SO. IN. OF NET FREE AREA / FT. FOR TILE <br />NOTE: <br />EXTERIOR WINDOWS, SLIDING DOORS AND EXTERIOR SIDE -HINGE <br />DOORS SHALL BE TESTED AND LABELED WITH A PERMANENT LABEL <br />PROVIDING TRACEABILITY TO MANUFACTURER AND PRODUCT <br />M <br />0 <br />LO <br />' o%. O <br />C0 <br />v� LO <br />UW. }; < <br />�: q Q <br />Z <br />W <br />0 <br />W <br />0 <br />z <br />c: <br />to N - <br />^, � E <br />0 o <br />I) (y) N `I <br />N M <br />f <br />(n V .0 O d <br />7 <br />78 <br />o0g 8 <br />._ 1 <br />�N w O � <br />QN <br />L <br />W p E� <br />W <br />ui c W O F- <br />Wed ��� ��YZtr Z <br />W (� W <br />< Q U <br />`� <br />X5-�U)03,W L0 LL <br /><oxQ�zw 0Z200�_ <br />O 0x2 0 Z o rr0 o m Q z U <br />c 0O Z <br />�nWaWV5WWWM0 xx¢:) <br />QiQoWQV5zWZOi3m <br />W <br />OW �H� Z a <br />oQ o 0 o¢QLL <br />O <br />ZW <br />O� <br />( 5 <br />0 cO <br />QWjCIO <br />I,f <br />W ti <br />QWQLO <br />F-" 0r cM <br />O <br />Q Q <br />z U I— <br />z <br />1 20 3 <br />W <br />j o <br />O <br />ed <br />dition <br />Nco <br />N <br />M <br />N <br />N <br />N <br />N <br />t: <br />N <br />4 <br />T- <br />4 <br />e- <br />0 <br />NO <br />o <br />0 <br />0 <br />0 <br />0 <br />CO <br />0) <br />(D W O O 0 r- <br />�-- <br />0 <br />0000000 <br />N N N N N N N <br />6 00 L� 00 O <br />N O e� D N M <br />N <br />rn <br />o00��Do <br />o <br />NLO�o000000 <br />r N M tt U*)' COI f-- <br />L <br />CO' <br />0. <br />vJ <br />Z Z <br />O <br />O�-' <br />W� <br />w CO <br />WU�> <br />CF)O <br />Via <br />"� <br />OWi <br />zWF-I- <br />� <br />�mOZ <br />Q :I <br />OZ3W <br />rill, <br />. <br />100 >.<z0 <br />M. �Zz <br />W O_j2z <br />Ng <br />VU)zco <br />=QO <br />CK■ <br />.Z <br />Z0 ~ U <br />_11111� <br />U� <br />O <br />; <br />co <br />I <br />Q <br />z <br />Z <br />Z <br />W <br />J <br />CV) <br />W <br />0 <br />0 <br />Q <br />LAST PLOT DATE <br />May. 9, 23 <br />Z <br />0 <br />EXTERIOR <br />J <br />ELEVATIONS A & <br />ROOF PLAN <br />