My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6622 Back Forty Loop
Zephyrhills
>
Building Department
>
Building Plans
>
6622 Back Forty Loop
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 2:05:18 PM
Creation date
2/27/2025 11:25:06 AM
Metadata
Fields
Template:
Building Plans
Street #
6622
Location
Back Forty Loop
Contractor
Lennar Homes
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN A <br />1 /411 = 1'-011 <br />LINE OF ROOF <br />— —1w+ <br />SECOND FLOOR ELECTRICAL PLAN A <br />1 /411 = 1'-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS -WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />10 <br />#15 copper to lights & outlets <br />NEMA 1 <br />200 AMP 10 <br />#12 copper to 20 amp ckts <br />--� <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />Lj <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET r� <br />TRIM <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ <br />�C_SMOKE DETECTOR <br />it - <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />AT 12" - TOP PLUG IS HOT <br />HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />be SWITCH AT 36" <br />co <br />-69 3 WAY SWITCH AT 36" <br />-esr 4 WAY SWITCH AT 36" <br />—� PUSH BUTTON FOR GARAGE DOOR OPENER <br />--� DIMMER SWITCH AT 36" JU <br />—� PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />-} CLG MNT PREWIRE - FIXTURE BY Virtuffeview Assist. <br />{} SURFACE MNT FIXTURE Plans Review completed and <br />T for compliance with the 2020 F <br />{t)- WALL MNT FIXTURE by Rebra Anne KIM,, P <br />NOTE: <br />ND OPALEX - ALTERNATE <br />TUB SHOWERCANS MAY BE <br />4� 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />�0 50W MR16 4" LOW VOLTAGE OWNER <br />`08`� 50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-} CLG FAN PREWIRE AND SWITCH <br />Cs COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />C SMOKE DETECTOR <br />C1.1-182 <br />UNDER CABINET 18" <br />=S-18= <br />SINGLE 18" FLUOR STRIP <br />=U-24= <br />UNDER CABINET 24" <br />=S-24= <br />SINGLE 24" FLUOR STRIP <br />=D-24= <br />DOUBLE 24" FLUOR STRIP <br />— U-36 = <br />UNDER CABINET 36" <br />c S-36 — <br />SINGLE 36" FLUOR STRIP <br />— D-36 — <br />DOUBLE 36" FLUOR STRIP <br />c S-48 <br />SINGLE 48" FLUOR STRIP <br />c D-48 <br />DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24::RR 24" VANITY LIGHTING <br />F_-36 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />123 CHIMES (DELETE W/ INTERCOM) <br />= MASTER STATION <br />11&J ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />ll A/C REGISTER <br />THERMOSTAT <br />On SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />i <br />i <br />r> <br />0 <br />N <br />rn <br />o <br />00 <br />LU <br />LU <br />"M 0,0 <br />} D a W <br />N d co-0 ` t <br />.o <br />4� 5 V 8 <br />+� 8 <br />o �g Q <br />�.� <br />fib, <br />W Lv. p ECO 0 <br />a a <br />1: <br />LLI <br />C) LLI Vj w O <br />~W WLUwYzh-m Z <br />Q (D LLI <br />Q <br />_ 0�MLL00LL0 <br />�N <br />QxJxOZ200�=O�z <br />2Z zoom Z <br />0Z�wanww <br />anw � <br />z¢ <br />Zm M ��pWU5WzOwo� ¢QaQo <br />LL <br />Zo <br />LL o a u. <br />O <br />ZCN <br />W <br />OI_ <br />CD 5 ti <br />C]F-MO <br />< wMLC <br />a. co <br />1 2023 <br />Q Q O <br />Z U <br />W <br />W <br />JC) <br />prove <br />CO <br />It <br />t Pd' on <br />0 <br />0 <br />0 <br />0 <br />r,� <br />4 <br />4 <br />O <br />N <br />O <br />N <br />O <br />O <br />O <br />40 <br />o a13, <br />CO <br />OQ <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />N <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />00 <br />O <br />Liso0 <br />§ <br />A <br />16 <br />� <br />N <br />0 <br />0 <br />O <br />c <br />0 <br />co <br />0 <br />o <br />0 <br />0 <br />d <br />0 <br />0 <br />0 <br />0 <br />m <br />Z <br />Z O <br />_ <br />oLUW <br />O <br />Uo <br />F—O <br />Q <br />a <br />Owl= <br />.YL <br />^ <br />��//�� <br />V1 <br />—a <br />r� <br />Q <br />=000Z <br />N <br />rt� <br />vZ <br />_j <br />i'nzx <br />M <br />CL <br />Z u. <br />LU N <br />0a1w <br />N <br />a <br />��Z <br />■ <br />Z <br />~ O <br />U <br />Z <br />U <br />O <br />a.O <br />W <br />� <br />Z <br />Z <br />z <br />w <br />J <br />M <br />Uj rn <br />�i�/ <br />Q <br />>Q <br />LAST PLOT DATE <br />May. 9, 23 <br />z 0 <br />1ST & 2ND FLOOR <br />J <br />ELECTRICAL PLAN <br />A <br />
The URL can be used to link to this page
Your browser does not support the video tag.