Laserfiche WebLink
1 ■ 2 ■ 3 ■ 4 ■ 5 ■ 6 ■ 7 ■ 8 ■ 9 ■ 10 ■ 11 ■ 12 ■ 13 ■ 14 ■ 16 ■ €6 ■ 17 ■ 18 ■ 19 ■ 20 <br />R <br />■ <br />P <br />■ <br />0 <br />■ <br />N <br />■ <br />M <br />■ <br />L <br />■ <br />K <br />■ <br />■ <br />. H <br />■ <br />G <br />■ <br />F <br />E <br />■ <br />• D <br />■ <br />N <br />B <br />■ <br />A <br />ELECTRIC WATER HEATERS <br />UNIT CAPACITY <br />ELECTRICAL DATA <br />DIMENSIONS <br />UNIT <br />NUMBER <br />MANUFACTURER & MODEL <br />NUMBER <br />SERVICE <br />LOCATION <br />TYPE <br />ASME <br />RATED <br />MAXIMUM <br />PRESSURE <br />SYSTEM <br />OUTLET <br />TEMP <br />OPERATING <br />WEIGHT <br />NOTES <br />STORAGE <br />RECOVERY <br />DEGREE <br />NUMBER <br />KW <br />SIMULTANEOUS I <br />POWER <br />EMERGENCY <br />LENGTH <br />WIDTH <br />HEIGHT <br />(PSI) <br />(GAL) <br />(GPH) <br />RISE <br />of <br />( ) <br />OF <br />PER <br />NONSIMULTANEOUS <br />(KW) <br />V <br />PH <br />HZ <br />POWER <br />(INCH) <br />) <br />(INCH) <br />(INCH) <br />LB <br />( ) <br />( F) <br />ELEMENTS <br />ELEMENT <br />EWH <br />1 <br />AO SMITH - DEL-20 <br />HOT WATER <br />MAINTENANCE <br />TANK TYPE - LIGHT <br />NO <br />150 <br />20 <br />34 <br />54 <br />120 <br />1 <br />4.5 <br />NON -SIMULTANEOUS <br />4.5 <br />208 <br />1 <br />60 <br />NO <br />- <br />22 <br />23 <br />235 <br />COMMERCIAL <br />GENERAL NOTES: <br />A. PIPE TEMPERATURE AND PRESSURE RELIEF VALVE TO SERVICE SINK <br />PLUMBING FIXTURES <br />TAG <br />FIXTURE DESCRIPTION <br />MANUFACTURER & MODEL <br />PART DESCRIPTION <br />NUMBER <br />S-1 <br />SERVICE SINK <br />BOWL -AMERICAN STANDARD - LAKEWELL SERVICE SINK <br />BOWL-18"x15"x10" ENAMELED CAST IRON BOWL W/ DRILLED BACK FOR FAUCET <br />FAUCET - CHICAGO - 897-CCP <br />FAUCET - FAUCET MOUNTED ABOVE FIXTURE WITH INTERNAL CHECK STOPS, VACUUM BREAKER, HOSE THREAD OUTLET & BUCKET HOOK. <br />BACK FLOW - BRADLEY S45-2310 <br />BACK FLOW - ASSE 1012 BACKFLOW PREVENTER <br />GENERAL NOTES: <br />A. ALL PLUMBING FIXTURES SHALL MEET LOCAL CODE REQUIREMENTS FOR WATER CONSUMPTION AND ACCESSIBILITY. <br />EXPANSION TANKS <br />DIMENSIONS <br />MANUFACTURER & <br />TANK <br />ACCEPTANCE <br />REPLACEABLE <br />PRESSURE <br />ASME <br />OPERATING <br />UNIT <br />NUMBER <br />MODEL NUMBER <br />SERVICE <br />LOCATION <br />VOLUME <br />VOLUME <br />BLATTER <br />RATING <br />RATED <br />DIAMETER <br />HEIGHT <br />WEIGHT <br />NOTES <br />(GAL) <br />(GAL) <br />(PSI) <br />(INCH) <br />(INCH) <br />(LBS) <br />ET <br />1 <br />AMTROL - ST-5C-DD <br />HOT WATER <br />MAINTENANCE <br />2 <br />0.9 <br />NO <br />150 <br />NO <br />8 <br />14 <br />10 <br />GENERAL NOTES: <br />A. SET THE TANK PRESSURE TO EQUAL THE SYSTEM OPERATING PRESSURE. TANK MUST BE DRAINED BEFORE ADJUSTING SET PRESSURE, <br />w <br />I <br />FLOOR SINKS AND FLOOR/ROOF/AREA DRAINS <br />GRATE/DOME <br />SIZE <br />OPEN FREE <br />TAG <br />MANUFACTURER & <br />DESCRIPTION <br />BODY MATERIAL <br />OUTLET <br />ACCESSORIES <br />NOTES <br />MODEL NUMBER <br />AREA <br />MATERIAL <br />SHAPE <br />LOCATION <br />(INCH) <br />(SQ.IN.) <br />RD-1 <br />ZURN - ZC100-DP-DR <br />PRIMARY ROOF DRAIN <br />DURA COATED CAST IRON <br />15" DIA. <br />103 SQ. IN. <br />CAST IRON <br />CIRCLE <br />BOTTOM <br />DECK PLATE & DRAIN RISER <br />GENERAL NOTES: <br />A. BEFORE SETTING DRAINS, OBTAIN EXACT INFORMATION RELATIVE TO FINISH FLOOR LEVEL AT TOP OF DRAINS AND TYPE OF ROOF CONSTRUCTION FOR ROOF DRAIN... <br />B. ALL FLOOR DRAINS SHALL HAVE A FINISH THAT IS FLUSH WITH THE FINISHED FLOOR. <br />C. DRAIN OUTLET SIZES ARE INDICATED ON THE DRAWINGS. <br />VACUUM RELIEF VALVE <br />(TYP.) <br />I <br />THERMOMETERion <br />--� 5 1 CW <br />HOSE BIBB <br />1"HW <br />of <br />3/4" CW-- <br />THERMAL <br />EXPANSION TANK <br />ET <br />1 <br />I <br />UNION (TYP) <br />TEMP. & PRESSURE RELIEF <br />PROVIDE GALVANIZED STEEL WATER <br />VALVE <br />HEATER RESTRAINT AND SECURE TO <br />WALL PER MANUFACTURERS <br />❑ <br />RECOMMENDATIONS. <br />PIPE RELIEF VALVE DISCHARGE <br />TO SERVICE SINK <br />SUPPORT BRACE <br />ELEMENT ACCESS PANEL <br />PIPE 1" PAN DRAIN TO <br />SERVICE SINK <br />-EW y <br />TANK DRAIN VALVE <br />WALL <br />PLATFORM ATTACH TO WALL PER <br />FLOOR <br />MANUFACTURERS RECOMMENDATIONS <br />NOTE: <br />1. WATER HEATER IS LOCATED <br />ON WALL SHELF WITH PAN EQUAL TO HOLDRITE WALL -HUNG PLATFORM. <br />ELECTRIC WATER <br />HEATER - WALL <br />HUNG <br />NTS <br />PLUMBING ABBREVIATIONS <br />A/C <br />ABOVE CEILING <br />HVAC <br />HEATING, VENTILATION, & AIR CONDITIONING <br />ACFM <br />ACTUAL CUBIC FEET PER MINUTE <br />IE <br />INVERT ELEVATION <br />ADA <br />AMERICANS WITH DISABILITIES ACT <br />ID <br />INSIDE DIAMETER <br />AFF <br />ABOVE FINISHED FLOOR <br />INV <br />INVERT <br />AFG <br />ABOVE FINISHED GRADE <br />IN. HG <br />INCHES MERCURY <br />ANSI <br />AMERICAN NATIONAL STANDARD INSTITUTE <br />IN. W.C. <br />INCHES WATER COLUMN <br />AP <br />ACCESS PANEL <br />IVTR <br />INDUSTRIAL VENT THROUGH ROOF <br />ARCH <br />ARCHITECT OR ARCHITECTURAL <br />KW <br />KILOWATT <br />ASTM <br />AMERICAN SOCIETY OF TESTING MATERIALS <br />LB <br />POUND <br />BFF <br />BELOW FINISHED FLOOR <br />LWVTR <br />LABORATORY WASTE VENT THROUGH ROOF <br />BFV <br />BUTTERFLY VALVE <br />MAX <br />MAXIMUM <br />BHP <br />BRAKE HORSEPOWER <br />MBH <br />THOUSAND BTU PER HOUR <br />B/F <br />BELOW FLOOR <br />MECH <br />MECHANICAL <br />B/G <br />BELOW GRADE <br />MFR <br />MANUFACTURER <br />B/S <br />BELOW SLAB <br />MIN <br />MINIMUM <br />BTU <br />BRITISH THERMAL UNITS <br />NC <br />NORMALLY CLOSED <br />BTUH <br />BRITISH THERMAL UNITS PER HOUR <br />NIC <br />NOT IN CONTRACT <br />BV <br />BALL VALVE <br />NO <br />NORMALLY OPEN <br />°C <br />DEGREES CELSIUS <br />NPSH <br />NET POSITIVE SUCTION HEAD <br />CFH <br />CUBIC FEET PER HOUR <br />NTS <br />NOT TO SCALE <br />CFM <br />CUBIC FEET PER MINUTE <br />OD <br />OUTSIDE DIAMETER <br />CONN <br />CONNECT OR CONNECTION <br />OFCI <br />OWNER FURNISHED CONTRACTOR INSTALLED <br />CONT <br />CONTINUATION <br />PLBG <br />PLUMBING <br />CONTR <br />CONTRACTOR <br />PSI <br />POUNDS PER SQUARE INCH <br />DEG <br />DEGREE <br />POC <br />POINT OF CONNECTION <br />DFU <br />DRAINAGE FIXTURE UNITS <br />PRV <br />PRESSURE REDUCING VALVE <br />DN <br />DOWN <br />PV <br />PRESSURE RELIEF VALVE <br />DWG <br />DRAWING <br />PVC <br />POLYVINYL CHLORIDE <br />ECO <br />EXTERIOR CLEAN OUT <br />QTY <br />QUANTITY <br />EFF <br />EFFICIENCY <br />RPZ <br />REDUCED PRESSURE ZONE BACKFLOW <br />PREVENTER <br />ELEC <br />ELECTRICAL <br />RM <br />ROOM <br />ELEV <br />ELEVATION <br />RPM <br />REVOLUTIONS PER MINUTE <br />EQUIP <br />EQUIPMENT <br />SCFM <br />STANDARD CUBIC FEET PER MINUTE <br />OF <br />DEGREES FAHRENHEIT <br />SF <br />SQUARE FEET <br />FCO <br />FLOOR CLEAN OUT <br />SHT <br />SHEET <br />FFE <br />FINISH FLOOR ELEVATION <br />SOV <br />SHUT OFF VALVE <br />FLR <br />FLOOR <br />SPEC <br />SPECIFICATION <br />FT <br />FEET <br />SS <br />STAINLESS STEEL <br />FU <br />FIXTURE UNITS <br />TEMP <br />TEMPERATURE <br />GAL <br />GALLONS <br />TYP <br />TYPICAL <br />GALV <br />GALVANIZED <br />T&P <br />TEMPERATURE AND PRESSURE RELIEF VALVE <br />GLV <br />GLOBE VALVE <br />LINO <br />UNLESS NOTED OTHERWISE <br />GPF <br />GALLONS PER FLUSH <br />UV <br />ULTRA VIOLET <br />GPH <br />GALLONS PER HOUR <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />GPM <br />GALLONS PER MINUTE <br />VTR <br />VENT THROUGH ROOF <br />GV <br />GATE VALVE <br />V/PH/HZ <br />VOLTS/PHASE/HERTZ <br />HD <br />HEAD <br />W/ <br />WITH <br />HP <br />HORSEPOWER <br />WCO <br />WALL CLEAN OUT <br />HR <br />HOUR <br />WHA <br />WATER HAMMER ARRESTOR <br />TAGS AND CALL OUT SYMBOLS <br />EQUIP <br />EQUIPMENT REQUIRING ELECTRICAL <br />A <br />REVISION CALLOUT <br /># <br />SERVICE. REFER TO SCHEDULES FOR <br />PERFORMANCE REQUIREMENTS. <br />XO <br />KEYNOTE CALLOUT <br />EQUIP <br />EQUIPMENT NOT REQUIRING ELECTRICAL <br />POINT OF CONNECTION <br />B <br />SERVICE. REFER TO SCHEDULES FOR <br />PERFORMANCE REQUIREMENTS. <br />e <br />POINT OF DEMARCATION <br />SECTION CALLOUT <br />HEAT TRACE CIRCUIT START AND END <br />X <br />SECTION DESIGNATION <br />HEAT TRACE CIRCUIT NUMBER <br />)OO( <br />SHEET NUMBER <br />DETAIL CALLOUT <br />A <br />DETAIL DESIGNATION <br />P3.1 <br />SHEET NUMBER <br />PLUMBING HEALTHCARE PIPING LEGEND <br />-0O2- <br />CARBON DIOXIDE <br />- MV -- --- <br />MEDICAL VACUUM <br />IA <br />INSTRUMENT AIR <br />N2 <br />NITROGEN <br />LN2 <br />LIQUID NITROGEN <br />N20 --- <br />NITROUS OXIDE <br />L02— <br />LIQUID OXYGEN <br />02 <br />OXYGEN <br />----�------MA <br />MEDICAL AIR <br />�-----WAGD�-----�-- <br />WASTE ANESTHETIC GAS DISPOSAL <br />PLUMBING SYMBOL LEGEND <br />C <br />PIPING TURN DOWN OR DROP <br />+� <br />WALL HYDRANT <br />0— <br />PIPING TURN UP OR RISE <br />�— <br />UNION <br />- <br />PIPING TEE DOWN OR DROP <br />PETE'S PLUG <br />Fs <br />0— <br />PIPING TEE UP OR RISE <br />FLOW SWITCH <br />Ps <br />OC <br />P-TRAP <br />PRESSURE SWITCH <br />--— <br />GATE VALVE <br />AUTOMATIC AIR VENT <br />CHECK VALVE <br />EXPANSION JOINT <br />O i <br />BALL VALVE <br />�- <br />PUMP <br />If <br />MIXING VALVE <br />�- <br />METER <br />xi <br />BUTTERFLY VALVE <br />PRESSURE GAUGE WITH GAUGE COCK <br />AO-AC <br />GLOBE VALVE <br />VALVE ON PIPING RISE OR DROP <br />PRESSURE REDUCING VALVE <br />� <br />AQUASTAT <br />—� �- <br />PLUG VALVE <br />TRAP PRIMER <br />-{�]-- <br />BACKFLOW PREVENTER <br />THERMOMETER <br />-- <br />BALANCING VALVE <br />WATER HAMMER ARRESTOR <br />TEMP. & PRESSURE RELIEF VALVE <br />PRESSURE RELIEF VALVE <br />VACUUM RELIEF VALVE <br />MOTORIZED SHUT-OFF VALVE <br />DIRECTION OF FLOW <br />SLOPE & DIRECTION OF FALL <br />OR INCREASER <br />DIAMETER <br />is <br />J, <br />i <br />Cl--REDUCER <br />0 <br />-- <br />SOLENOID VALVE <br />@ <br />DRAIN RECEPTOR <br />STRAINER <br />I� �I <br />FLOOR DRAIN <br />FLOOR CLEAN OUT <br />III <br />AREA DRAIN <br />WALL CLEAN OUT <br />FLOOR SINK <br />Q� <br />EXTERIOR CLEAN OUT <br />O <br />ROOF DRAIN <br />CAPPED PIPE / CLEAN OUT <br />O <br />SECONDARY ROOF DRAIN <br />CONTINUATION <br />(E) <br />EXISTING <br />FLEXIBLE CONNECTION (PIPE) <br />�- <br />HOSE BIBB <br />PLUMBING PIPING LEGEND <br />_ _w___CWW______, <br />CLEAR WATER WASTE ABOVE FLOOR OR <br />- -- - - - <br />INDUSTRIAL WASTE BELOW FLOOR OR <br />GROUND <br />— IW — _ <br />GROUND <br />CWW® �� <br />CLEAR WATER WASTE BELOW FLOOR OR <br />—KW <br />KITCHEN WASTE ABOVE FLOOR/GROUND <br />GROUND <br />-- CWV -- <br />CLEAR WATER WASTE VENT <br />- KW — - <br />KITCHEN WASTE BELOW FLOOR/GROUND <br />CW <br />COLD WATER <br />-- LPG <br />LIQUID PETROLEUM GAS <br />—CWHP— <br />COLD WATER HIGH PRESSURE <br />G <br />NATURAL GAS <br />COMBINED STORM DRAIN ABOVE FLOOR <br />HG <br />NATURAL GAS - HIGH PRESSURE <br />OR GROUND <br />MG <br />NATURAL GAS - MEDIUM PRESSURE <br />COMBINED STORM DRAIN BELOW FLOOR <br />- --. CSD - <br />OR GROUND <br />-�--•PD�------ <br />PUMP DISHARGE <br />CA <br />COMPRESSED AIR <br />RW <br />RECLAIMED WATER <br />------�---- CAI ---- ----� <br />COMPRESSED AIR INTAKE <br />RO <br />REVERSE OSMOSIS WATER <br />DI�-° <br />DEIONIZED WATER SUPPLY <br />- — — — - <br />- —ROR— - <br />REVERSE OSMOSIS WATER RETURN <br />DIR <br />DEIONIZED WATER RETURN <br />S <br />SANITARY SEWER ABOVE FLOOR/GROUND <br />- ---FOR--- - <br />FUEL OIL RETURN <br />- -- -g- — - <br />SANITARY SEWER BELOW FLOOR/GROUND <br />FO--- <br />FUEL OIL SUPPLY <br />— --V-- ---�- <br />SANITARY SEWER VENT <br />GW <br />GRAY WATER ABOVE FLOOR OR GROUND <br />SSD <br />SECONDARY STORM DRAIN ABOVE <br />FLOOR OR GROUND <br />-- �W-- - <br />GRAY WATER BELOW FLOOR OR GROUND <br />- <br />SECONDARY STORM DRAIN BELOW <br />- —SSD— -- <br />FLOOR OR GROUND <br />HW <br />HOT WATER <br />---SCW-- <br />SOFT COLD WATER <br />—HW140— <br />HOT WATER (140°F) <br />�--SHW-- <br />SOFT HOT WATER <br />—HWR140--�- <br />HOT WATER RETURN (140°F) <br />'SHWR- -- <br />SOFT HOT WATER RETURN <br />SD <br />STORM DRAIN ABOVE FLOOR/GROUND <br />—HW160— <br />HOT WATER (160°F) <br />- — SD — - <br />STORM DRAIN BELOW FLOOR/GROUND <br />-��HWR160-- <br />HOT WATER RETURN (1607) <br />- -----SUB---- �- <br />SUBSURFACE STORM DRAIN <br />--�HWR-- <br />HOT WATER RETURN <br />----- .TP--_-.....-�. <br />TRAP PRIMER <br />-~~�~~~~~ICW~�-~- <br />INDUSTRIAL NONPOTABLE COLD WATER <br />~~~~-TW----- - <br />TEMPERED WATER <br />IHW----- <br />INDUSTRIAL NONPOTABLE HOT WATER <br />m TWR-- <br />TEMPERED WATER RETURN <br />---�----IHWR---- <br />INDUSTRIAL NONPOTABLE HOT WATER <br />RETURN <br />VAC <br />VACUUM <br />INDUSTRIAL NONPOTABLE SOFT COLD <br />WATER <br />INDUSTRIAL NONPOTABLE SOFT HOT <br />--,-VEX--,----- <br />VACUUM EXHAUST <br />--�W--�ISHW--� <br />WATER <br />----ISHWR-- <br />INDUSTRIAL NONPOTABLE SOFT HOT <br />�----WO----- <br />WASTE OIL <br />WATER RETURN <br />_ WOV <br />WASTE OIL VENT <br />-IV- <br />INDUSTRIAL VENT <br />INDUSTRIAL WASTE ABOVE FLOOR OR <br />'T <br />DEMOLITION PIPING <br />--~-�-IW----- <br />GROUND <br />DEMOLITION EQUIPMENT <br />expU.S. Services Inc. <br />t: +1.407.660.0088 <br />f: +1.407.660.1655 <br />2601 Westhall Lane <br />Maitland, FL 32751 <br />USA <br />dIi <br />tip <br />www.exp.com <br />• �a <br />; • <br />Project #: 21011327 <br />exp, <br />Cert of Auth: 29701 <br />SEAL <br />Hunton i <br />A R C H I T E C T <br />DATE SUBMISSION NO <br />12.17.21 CONSTRUCTION DOCUMENTS <br />PLUMBING LEGEND <br />PROJ. NO. H-15027.00 SHEET <br />DRAWN Author <br />PMOO 1 <br />1 ■ 2 ■ 3 ■ 4 ■ 5 ■ 6 ■ 7 ■ 8 ■ 0 ■ 10 ■ 11 ■ 12 ■ 13 ■ 14 ■ 16 <br />■ 16 ■ 17 ■ 18 ■ 19 ■ 20 <br />Copyright HuntonBrady Architects P.A. All Rights Reserved. 333 S. Garland Ave., Suite 1100, Orlando, Florida 32801 (407) 839-0886 (407) 839-1709/Fax www.huntonbrady.com License AR91515 <br />