My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (114)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (114)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:53:58 PM
Creation date
2/27/2025 11:26:59 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Berglund Construction
Building Plans - Permit #
3600
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 ■ 2 ■ 3 ■ 4 ■ 5 ■ 6 ■ 7 ■ 8 ■ 9 ■ 10 ■ 11 ■ 12 ■ 13 ■ 14 ■ 15 ■ 16 ■ 17 ■ 18 ■ 19 ■ 20 <br />R <br />■ <br />P <br />■ <br />0 <br />■ <br />N <br />■ <br />1�1 <br />■ <br />L <br />■ <br />K <br />■ <br />J <br />■ <br />H <br />■ <br />■ <br />F <br />■ <br />E <br />■ <br />D <br />■ <br />■ <br />r.. <br />A <br />cry <br />2 FIRE PROTECTION FIRST FLOOR - AREA 1 <br />1/8" = V-0" <br />HYDRAULICALLY CALCULATED PIPE CHART <br />FOR EXISTING SYSTEM BRANCH LINES <br />(STEEL) <br />PIPE SIZE <br />NUMBER OF <br />SPRINKLERS <br />1 INCH <br />1 <br />1 1/4 INCH <br />2 TO 3 <br />1 1/2 INCH <br />4 TO 7 <br />2 INCH <br />8 TO 12 <br />NOTE: ALL NEW SPRINKLER BRANCH LINE <br />SIZES SHALL MATCH EXISTING BRANCH <br />LINE SIZES. <br />DESIGN DENSITY <br />HAZARD <br />CATEGORY <br />SPRINKLER HEAD <br />SPACING <br />HOSE <br />ALLOWANCE <br />SPRINKLER DESIGN DEMAND (gpm/ft2)/ft2 <br />WET <br />DRY <br />❑A <br />LIGHT HAZARD <br />225 <br />100 <br />0.10/1500 <br />0.10/1950 <br />© <br />ORDINARY HAZARD GROUP 1 <br />130 <br />250 <br />0.15/1500 <br />0.15/1950 <br />© <br />ORDINARY HAZARD GROUP 2 <br />130 <br />250 <br />0.20/1500 <br />0.20/1950 <br />EXTRA HAZARD GROUP 1 <br />100 <br />500 <br />0.30/2500 <br />0.30/3250 <br />0 <br />ROOM TO BE PROTECTED BY CLEAN AGENT FIRE SUPPRESSION SYSTEM. <br />GENERAL NOTES: <br />1 THE DESIGN OF THE FIRE PROTECTION/SUPPRESSION SYSTEM IS SCHEMATIC ONLY. <br />CONTRACTOR AND MANUFACTURER SHALL BE RESPONSIBLE FOR ACTUAL DESIGN AND <br />PERFORMANCE PER THE APPLICABLE SPECIFICATIONS AND CODES. <br />2 ALL EXISTING FIRE PROTECTION COMPONENTS SHOWN ON THIS PLAN ARE TAKEN FROM AS <br />BUILT DRAWINGS PROVIDED BY THE OWNER AND HAVE BENNE GENERALLY VERIFIED. <br />CONTRACTOR TO VERIFY ALL AREAS OF DEMOLITON PRIOR TO BID. <br />KEY NOTES <br />231 EX. 3" SPRINKLER CROSS MAIN. <br />232 EX. 4" SPRINKLER RISER AND DRAIN, <br />233 EX. 3" SPRINKLER CONTROL VALVE ASSEMBLY. <br />234 EX. 4" SPRINKLER MAIN UP TO LEVEL 2. <br />235 EX. 3" SPRINKLER MAIN SERVING ADJACENT STRUCTURE. <br />236 EX. FIRE DEPT. CONNECTION. <br />240 NEW. 3" SPRINKLER CROSS MAIN. <br />241 CONNECT NEW 1'/2' SPRINKLER BRANCH LINE TO EX.1%" SPRINKLER BRANCH LINE. <br />242 CONNECT NEW 1" SPRINKLER BRANCH LINE TO EX. 1" SPRINKLER BRANCH LINE <br />243 CONNECT NEW 1'/2" SPRINKLER BRANCH LINE TO EX. 3" SPRINKLER CROSS MAIN. <br />244 CONNECT NEW 3" SPRINKLER CROSS MAIN TO EX. 3" SPRINKLER CROSS MAIN. <br />245 CONNECT NEW 1'/<" SPRINKLER BRANCH LINE TO EX.1'/<" SPRINKLER BRANCH LINE. <br />246 CONNECT NEW 2" SPRINKLER BRANCH LINE TO EX. 3" SPRINKLER CROSS MAIN. <br />247 SPRINKLER CONTRACTOR TO PROVIDE DRIP TRAY UNDER ALL SPRINKLER PIPING OVER <br />ELEC. EQUIPMENT. <br />..... <br />Y- .... <br />.... .. .. <br />... .. ... _ <br />. _ <br />.. ..... .. . .... .. .._ .... <br />I <br />Jw <br />1 FIRE PROTECTION FIRST FLOOR -AREA 1 DEMO <br />118" =1'-0" <br />1 ■ 2 ■ 3 ■ 4 ■ 5 ■ 6 ■ 7 ■ 8 ■ 9 ■ 10 ■ 11 ■ 12 ■ 13 ■ 14 ■ 15 <br />exp U.S. Services Inc. <br />t: +1.407.660.0088 f: +1.407.660.1655 <br />2601 Westhall Lane <br />Maitland, FL 32751 <br />USA <br />i� <br />www.exp.com •��a <br />Project* 21011327 <br />exp. <br />Cert of Auth: 29701 <br />Hunton N&I'm <br />A R C H I T E C T <br />DATE SUBMISSION NO <br />12.17.21 CONSTRUCTION DOCUMENTS <br />FIRE PROTECTION FIRST FLOOR PLAN - <br />AREA 1 <br />PROJ. NO. H-15027.00 SHEET <br />DRAWN CMZ <br />Fml 02 <br />■ 16 ■ 17 ■ 18 ■ 19 ■ 20 <br />Copyright HuntonBrady Architects P.A. All Rights Reserved. 333 S. Garland Ave., Suite 1100, Orlando, Florida 32801 (407) 839-0886 (407) 839-1709/Fax www.huntonbrady.com License AR91515 <br />
The URL can be used to link to this page
Your browser does not support the video tag.