Laserfiche WebLink
t>D <br />m <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY I <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FETW.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />200A INDOOR PANEL <br />CENTER <br />10 1114 copperto lights & outlets <br />NEMA <br />00 AMP 1 <br />2(HI A <br />01 p12 copper to 20 amp ckts <br />10 #10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />MAIN <br />O <br />210 or <br />4/0 SER Alu <br />200 amp <br />IF <br />150 amp <br />POWER CO. FEED----._ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />WP DISC. <br />GFI H. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn 171= comnc <br />it PUSHBUTTON SWITCH (OPTIONAL) <br />1.o <br />I 0 <br />E <br />SD SMOKE DETECTOR <br />.___ j W H VERIFY LOCATION <br />_ <br />o <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />GFI — — — — — -----J ELECTRICAL PANEL <br />db <br />y <br />TELEPHONE (OPTIONAL)P�7 <br />L` <br />TELEVISION (OPTIONAL) <br />© <br />RECEPT. <br />VERIFY METER <br />o <br />FOR ALARM <br />E! <br />T©2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />SYSTEM LOCATION WITH <br />BUILDER <br />� ,I <br />O THERMOSTAT <br />MM ELECTRIC METER <br />0 <br />ELECTRIC PANEL <br />w <br />�a <br />i <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4rr=1 r-0rr <br />FMI <br />M <br />0 <br />CD <br />cnn, t� <br />'w <br />Q <br />�V <br />— <br />O LU <br />E <br />m <br />U <br />� M M <br />W <br />~ E <br />— 8 <br />C to CO <br />C N <br />O o 0 <br />_ <br />r LL � <br />Sao <br />Iv 0 <br />Q m <br />u7 a <br />C5 <br />BD <br />Nc <br />N <br />2 <br />Z 4 <br />Z <br />z OD <br />MCP <br />tA Z. <br />�I— owl <br />LL z <br />W=LLo <br />W V ¢ .Q <br />as <br />z <br />z O -acorn � <br />Z U1 E <br />LL <br />m m <br />W Q Q�w <br />—' o <br />b U <br />U �O <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />0 <br />Z N <br />O a� n <br />.+-' O <br />u>�+(nMO <br />M <br />U) Lr) <br />Q <br />V <br />_C) <br />Z <br />Q U_ <br />(j rB <br />C- 00 <br />Q u <br />Z IU <br />WJ <br />� <br />d' <br />oZ <br />Z a <br />Z� <br />�F <br />Z <br />w C Y ICL� <br />Z OU °U <br />U <br />�1J <br />LJ� <br />IZI--UZ <br />s 0 Lu <br />Q <br />0�u-8 <br />C) <br />"F�o <br />L <br />° in <br />zZ <br />�CZ, <br />>/ <br />w <br />g <br />LL <br />a <br />MJ <br />LU <br />0 <br />Ou <br />_ <br />O <br />�� <br />Q <br />ILL <br />>2 <br />° ° Z <br />Y7 <br />0 <br />J +�' <br />ara <br />U <br />0 <br />Q <br />w O <br />v a m a <br />r°aa0a <br />I� <br />wiz¢ <br />�aa <br />Q <br />Z <br />oafs <br />Z <br />W <br />Lf) <br />w <br /><�'� <br />J <br />r-q <br />Lij <br />Z <br />to o Z o <br />U <br />2� <br />N <br />Q <br />Z <br />ZZ <br />N <br />oo <br />Z <br />g <br />Uj <br />= <br />J ° <br />" w <br />,--I <br />a <br />LO <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAMES <br />VERSION NO. 10 <br />O <br />SHEET NO. <br />4.0 <br />