D2 <br />00 <br />ATTIC VENTILATION CALCULATIONS - B1 <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />21.00000 <br />2.000000 <br />Floor <br />2377 <br />2282 <br />326 <br />1141 <br />81 <br />570 <br />0 <br />591.0 <br />315.0 <br />276.0 <br />(Zone 1) <br />* NOTE" <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN. <br />SCALE: %4'=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water-Resisitive Barriers. <br />Water- resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 11300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN`* <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />Lo <br />cD <br />7._ M <br />Q <br />J <br />0W cn <br />4---J w <br />ro M <br />U — <br />W <br />LU <br />fO�1 <br />p m 04 <br />a <br />V <br />1..1..1 <br />,— E <br />— 8 <br />N M <br />N -0f6 M <br />0 O N <br />U <br />w LL 0000 <br />Y <br />N flo <br />u7 O sr <br /><C rn <br />M— o <br />AlY�O ®BID • <br />Vu cz,'/! ��•R .MKT <br />Ci <br />Z P <br />11 a <br />N <br />ILI <br />U ka <br />To the best of the Engin °stt� owledge; info(an4,F(, and <br />belief, the structural plans andFFWg4,VvigP!ibW&dAtalned <br />within these drawings comply with th'a"f817 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />0 <br />z rV <br />t\ <br />O <br />.N <br />z <br />> UP) roO <br />M <br />Q U-) fU L.f) <br />a Ln •L �t- <br />(5 <br />HL- LL Ln <br />C L <br />U p. <br />a OC) <br />� <br />z ra <br />W <br />110 <br />0, <br />O <br />w � <br />z <a <br />f <br />w¢ir� <br />UzUO0 <br />ZU z < <br />J <br />�Ore �W <br />t Y O <br />L <br />ZZ <br />Z <br />O <br />zz <br />z <br />r J <br />-0 <br />C:< <br />z <br />o <br />O <br />= <br />M <br />Q. <br />J <br />LL. <br />w <br />o� <br />Q o <br />t2 <br />I- <br />J <br />0 <br />X 0 <br />w 0 <br />N <br />cr <br />z<°< <br />�a?a <br />a <br />d- <br />S��o <br />z <br />Z <br />Ln6i <br />wDwo <br />a <br />w <br />° <br />LU <br />J <br />T.L <br />¢ <br />z <br />cnozO <br />U <br />LU¢8 <br />ce z <br />N <br />Z <br />m <br />O <br />N <br />00 <br />z <br />g <br />= <br />z <br />0 <br />w <br />T-r <br />a <br />to <br />SCALE : AS NOTED <br />DATE : 3/7/2018 <br />TECH: JMUROSIQ <br />VERSION No' 10 <br />O <br />SHEET NO. <br />5.0 <br />