ELECTRICAL SPECIFICATION <br />200AINDEL <br />CENNTERTER <br />NOTES: <br />#14 copper to lights &outlets <br />ELECTRICAL CONTRACTOR <br />NEMA 1 <br />200 AMP <br />10 #12 copper to 20 amp ckts <br />MUST VERIFY WITH THE <br />10 #10-2 copper to WH <br />SPECIFICATIONS FOR THE TYPE <br />10 #10-3 copper to Dryer <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />METER <br />T <br />LOCATION PURPOSES. <br />MAIN <br />2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING O <br />TERMINATION PER 71 <br />NEC 08, 250.94 J <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />�'4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />0 <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©V 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />_a <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />u <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />I <br />OWNER'S S��I ITE -- -�- 0 A -� W.I.C. <br />'1'-- <br />' <br />/ ROUGH -IN FOR <br />OPT. CLG. FAN/ I <br />LIGHT PRE -WIRE _ I <br />0 P------------f <br />----� t k <br />- � Y ?�I <br />PA 10 CAFE <br />IN, <br />I I <br />FAMILY RM <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I <br />I <br />GFI I <br />F I -- - <br />' I o <br />D.W. <br />' L-__J <br />INK / DIS <br />- U. IT H <br />PENDANT AS \ <br />PER SPECS <br />� r <br />EP)ADL <br />WP H.B. <br />GFI DISC. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />®L 'MI <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H.B. <br />IRRIGATION <br />VERIFY LOCATION GFI @ 44" A.F.F. <br />W H ELECTRICAL PANEL I <br />O 1 <br />I <br />I <br />I <br />2 CAR GARAGE <br />I <br />I <br />GFI FOR <br />GAR. DOOM <br />GFI <br />-_GFI @ 44" <br />A.F.F. <br />I <br />I <br />_ I <br />I A I <br />I <br />/ 1 <br />II <br />I <br />L------------ <br />GFI @ 44" <br />A.F.F. <br />I <br />ENTRY <br />I <br />' I <br />WP j <br />GFI I <br />BEDROOM 4 <br />ROUGH-IN FOR <br />7L-t OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=V-0" <br />(Dr <br />Z (M <br />0 <br />— o <br />z� <br />z� <br />Lu <br />Q <br />o <br />z <br />O <br />n07 <br />W <br />'I--J LLJ <br />Q <br />Ow <br />ry <br />E <br />o <br />107 <br />c J <br />v , F <br />(� <br />M c <br />m r` <br />U <br />0, <br />W <br />H o <br />Ct to M <br />N .0 M <br />— Q <br />O 20 <br />= a)= <br />U <br />LL co <br />to <br />C <br />n ao <br />4 <br />Q tT <br />u7 O V <br />CL <br />0) Q O <br />A' <br />B D. <br />N C a D C <br />N <br />N <br />N <br />�fl <br />Lo <br />.n N oo `- o rn o0 <br />V o o N <br />'Z iCi <br />Z W �Nnz —� <br />w_ � c <br />LL o o <br />z <br />, J <br />LU �y�N <br />W Q CL <br />ozo <br />j <br />aW <br />Z <br />m Z <br />o a <br />.n 1A a c O <br />m OHO <br />IUL (10, <br />dM <br />Wa°<NIt_t_ <br />V M <br />Jo <br />In <br />U <br />V O <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />ON <br />Z <br />O � n <br />0 <br />f>-+HMO <br />Q J) - <br />d ( i <br />L_ <br />Q U_ <br />F— 0-11-1-1 <br />UQ00 <br />Q <br />�� <br />Z <br />W <br />d' <br />J <br />oZ <br />= <br />ZU) <br />Lo <br />LU <br />Z g <br />Z <br />z <br /><a <br />} <br />UzQ�a <br />Q <br />g450 <br />J <br />Z.za <br />�oWZ <br />J <br />2_uj <br />o O o <br />OV <br />U <br />w N <br />FWo <br />L. <br />oN <br />o <br />/1 <br />/ <br />U <br />Z Z <br />Z <br />g <br />in� <br />W <br />(� <br />LJ <br />S <br />1 <br />� <br />O <br />_fu <br />O <br />O <br />a <br />w <br />o <br />QLL_ Y <br />O <br />J <br />7OC� <br />ul <br />2 ma <br />N <br />Q <br />a a <br />Z�� <br />��¢ce <br />`tOw3 <br />Z <br />o � o <br />WC-) <br />LJJ <br />�¢�_ <br />J <br />�.{ <br />L.Ic..I <br />N o <br />owu <br />w Y <br />r� <br />\ <br />G <br />Q <br />H <br />rl <br />Ln <br />Q <br />Z <br />Z <br />¢�Z <br />a� <br />z <br />m <br />0 <br />_ <br />¢o <br />LZU <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: ERAN D <br />VERSION N0. 2.,0 <br />SHEET NO. <br />4.0 <br />