Laserfiche WebLink
L!. Y!r'. vIIII III a !•._�L-_. I. <br />VENTED SOF <br />46 SQ. FT. <br />VCIN I GV O%j-r-I I V/ JV(. r l . <br />ATTIC VENTILATION CALCULATIONS - Al <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />ventilation of vented <br />IN. of <br />of <br />vented <br />ventilation to <br />be provided <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />(See Elev ) <br />required soffit <br />ventilation <br />soffit <br />by upper <br />Ventilation <br />Ventilation <br />needed <br />required <br />needed <br />ventilators <br />Main <br />29.00000 <br />1.000000 <br />Floor <br />2373 <br />2278 <br />325 <br />1139 <br />81 <br />570 <br />0 <br />573.0 <br />435.0 <br />138.0 <br />(Zone 1) <br />""NOTE** <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 5th ED. RESIDENTIAL. <br />VENTED SOFFIT LEGEND <br />71 <br />IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED <br />AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. <br />IF <br />LABELED AS "VENTED", NO FIRE PROTECTION WILL BE REQUIRED. <br />VENTED SOFFIT <br />'3OFFIT <br />ROOF PLAN <br />SCALE: %4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />**CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. <br />* (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />" Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT <br />**Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed <br />cD t2 <br />z o <br />0z� <br />z� <br />Q <br />J <br />!2. <br />co z <br />n) <br />W cn <br />'N w <br />� o <br />'u - <br />O w <br />I — <br />E <br />Of <br />/I ^) � <br />o <br />V1 F— <br />OM <br />O <br />w <br />C CY) <br />O <br />— U <br />aimE— E <br />f6 6 M <br />O o a <br />a) <br />V U00 <br />W <br />L L.L co <br />0Co <br />Y <br />L0 O O <br />u0 v <br /><C rn <br />rnQ o <br />A 1 <br />B D. <br />N c s o c <br />C <br />'t0 E t <br />CV <br />Z W �' ;' <br />� NL <br />:z <br />C' ) <br />w ai TR r <br />...�+ Lit <br />40 U3 <br />� CD ,. <br />`Z <br />r.L <br />O w o . <br />0- PI w 0,., <br />Y.�Ema>{..! <br />:r!(I�CRtB.sk <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />zo <br />U 0) r-, <br />t-1 -L-' O <br />L7-iO <br />Q -0 Lf) <br />( 'i I- <br />0- <br />to n <br />Q L.L <br />C)-e--, <br />170 <br />00 <br />Q V Q00 <br />z <br />E <br />Z <br />W._I C:) <br />d" <br />0 <br />oz <br />�o <br />w � <br />Za <br />f <br />F: <br />r <br />w ¢ n <br />VZOO <br />U <br />Q <br />Z w Z <br />= p W Z <br />HJLL� z <br />OLO <br />W <br />mz0 <br />O Ln <br />L <br />(3) <br />�• <br />} O <br />a <br />�-- <br />VT, <br />z <br />Z <br />V� <br />C: <br />M <br />' <br />C <br />z <br />o <br />o <br />Q <br />z <br />J Q <br />U <br />= <br />(u <br />^ <br />,J <br />> <br />J <br />se QQ <br />x O V <br />U2cr ma <br />OQOa <br />�Z¢ <br />Q <br />Q � W <br />io <br />Z <br />�a LL <br />W <br />Ln <br />Lij <br />LL.j <br />(Cz <br />a W <br />yr O Z o <br />0 v <br />W <br />~ 0 <br />ri <br />Q <br />z <br />< ce <br />as <br />Q <br />Qz <br />J <br />= <br />¢ z <br />r, <br />,—I <br />a <br />to <br />SCALE : AS NOTED <br />DATE ; 2/24/2014 <br />TECH: ERAND <br />VERSION N0. ^ . <br />0 <br />SHEET NO. <br />5.0 <br />