Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE'. <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoketcarbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and Windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />-� <br />FLOURESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />;0� EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />Flo <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />oSD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />t` <br />® <br />TELEVISION (OPTIONAL) <br />Z <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />DR <br />ELECTRIC METER <br />i <br />owl <br />PANEL <br />a <br />_1111111A <br />DISCONNECT SWITCH <br />00 <br />w <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />ev <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />6B <br />(1) PHONE LINE, (1) DATA PORT <br />200A INDOOR PANEL <br />#14 copper to tlpbte & outlets <br />NEMA <br />00 AMP 1 <br />200 A#12 copper to 20 amp ckts <br />#10.2 copper to WH <br />#103 copper to Dryer <br />0 µ <br />2!0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />Disc E#4 <br />POWER CO. FEED <br />INTERSYSTEM Bare Cu Ground <br />BONDING UNDINGWIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 14, 250.94 5P CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />VERIFY METER <br />LOCATION WITH <br />Rllll_DFR <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4'=1'-0" <br />_ul) <br />z '' <br />z� <br />Z <br />Q <br />a <br />U) z <br />W <br />cD �'1 <br />(DIMV)� <br />4—J w <br />Q <br />�V — <br />O <br />129 <br />E <br />LU <br />Elm <br />_ <br />U <br />u01 <br />- <br />c $ <br />Q <br />rR o <br />��Lo <br />A <br />Moss <br />'W <br />12 <br />t0 N <br />9 tD <br />c`t <br />fi 41 LL <br />�z Z <br />11J lL <br />W g � cLL <br />Z� <br />vQrw <br />� a <br />LL Z <br />W N <o <br />J $ <br />To the best of the Engineers knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />1f <br />0 <br />0 <br />Z fV <br />0 � N <br />IS <br />H M O <br />M <br />Q(A MLn <br />0. toZ <br />V) ON <br />Ln <br />a ^ <br />ZDC <br />rn <br />U '" { <br />Q C 000 <br />Z <br />WJ <br />CD <br />�a <br />..8,0 <br />ce <br />U <br />J <br />81 <br />W <br />Z <br />U <br />U) <br />LU <br />w <br />� <br />U <br />= <br />0Lu <br />z <br />0 gal <br />r14 <br />Q <br />rY <br />ujce <br />u <br />gL <br />Z <br />J <br />,..I <br />Ln <br />.. <br />tJJ <br />a <br />LU <br />m <br />o <br />g <br />ITJ <br />= <br />rl <br />r1 <br />Ln <br />f <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAM ES <br />VERSION NO. 5al <br />SHEET NO. <br />4.0 <br />