My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3193 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3193 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:03:56 AM
Creation date
2/19/2025 8:57:56 AM
Metadata
Fields
Template:
Building Plans
Street #
3193
Location
Kresterbrooke Ln
Contractor
Lennar Homes
Building Plans - Permit #
19985
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
14? <br />02 <br />C <br />a <br />co <br />00 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station cc alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination. smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />LZIN <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />_T4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WWALL <br />MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />El PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />_ I <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />69 <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 J <br />200A INDOOR PANEL <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Dpper to fights & outlets <br />Dpper to 20 coop Me <br />copper to WH <br />copper to Dryer <br />:au <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />RECEPT. <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />�_nnI <br />------EJ <br />UPPER ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />C9u, <br />�_ <br />Z M <br />Z <br />z <br />Q <br />J <br />a <br />U)V) <br />UI <br />tN <br />C6 <br />�V p <br />— <br />Ow <br />129 <br />Lr <br />V)C) <br />m N <br />U-1 <br />■. <br />N <br />1 <br />_ <br />l <br />=L <br />2 <br />c <br />Q om, <br />U, o <br />1 0 <br />Al I BID. <br />"� <br />F <br />'� <br />/r <br />TV <br />I <br />00 <br />iD N <br />o o ��� <br />� <br />Z_��� <br />A/ 4. Ngpi <br />W c u- <br />i0Z <br />�? <br />W LL <br />a a <br />Q <br />o � <br />� <br />Z <br />LLZ�^I <br />m o <br />��j <br />W �aN <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal Is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />O <br />Z fV <br />OIL <br />�>-+UMO <br />M <br />tj tG L^ <br />0 <br />G <br />CL <br />Z <br />Ce. U, � <br />Q 0000 <br />Z E <br />W <br />Z <br />u� <br />z <br />to <br />Za <br />480, <br />z <br />U4 Z, <br />J <br />a <br />Z -' <br />N <br />1$ <br />DC <br />L r) <br />W <br />Lu <br />N <br />N <br />I� <br />0 <br />= <br />ILL <br />W <br />o� . <br />INeP <br />0 <br />^ <br />cc <br />C <br />t�t� 0 <br />W <br /><0uj <br />ffl <br />Z <br />N <br />OOf <br />W <br />L <br />�Z4 <br />01 <br />Z <br />Z <br />11 <br />m <br />0 <br />N <br />0 <br />Z <br />� <br />L <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAMES <br />VERSION NO. 5ol <br />SHEET NO. <br />4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.