a <br />00 <br />Q <br />co <br />m <br />0 <br />_ <br />a <br />00 <br />N <br />w <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />NEMA1 <br />200 AMP <br />14 copperto lights & outlets <br />12 copper to 20 amp ckts <br />10.2 copper to W H <br />10-3 copper to Dryer <br />METER <br />11 <br />MAIN <br />U <br />2/0 or 4!0 SER Alu <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94--/ <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />Fff <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.f. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />TEF <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />e� <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />Q EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />O <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />^®^ <br />l <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />6� <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />VERIFY METER <br />LOCATION WITH <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=1 `-0" <br />zC> <br />O <br />Z <br />Q <br />r <br />Vn)' (D <br />W w <br />w <br />2 <br />~ <br />(/7 <br />o 0 <br />n. <br />m CN <br />C) <br />w <br />rnco m <br />c (ac <br />i pE <br />® U <br />C N <br />O p <br />Qj <br />a_- lL 05 <br />r� <br />wo <br />yam le <br />< t� <br />Q •u <br />(a Q Q <br />A 1 <br />N C a D C <br />m.V, <br />N <br />N <br />U N <br />o N� <br />ZW —�z <br />+N M <br />IF• o <br />w t, <br />N <br />W a > c U- <br />° a <br />W Oavairn5 <br />mow <br />Z <br />N co <br />iD E r <br />Z <br />LLco <br />o <br />m m <br />co _ <br />W Na�1 <br />0 <br />�d o <br />o� <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />0 <br />Z N <br />0 a� <br />1/1 L O <br />_- M <br />Q "� Ln <br />i <br />i <br />a ^ <br />cl� V CL rB � <br />a E� <br />Z <br />W <br />d' <br />12 <br />wE <br />zaa <br />F <br />Z <br />Q <br />W¢0 <br />U?S° <br />�1J <br />LL <br />INI—., <br />spwZ <br />J <br />J <br />Q <br />¢ 1' � J <br />U <br />o �18 <br />L© <br />o0Z <br />Z Z <br />0 <br />�z <br />(U <br />Ln <br />w <br />z <br />N <br />Ir <br />a <br />�� <br />V <br />= <br />O <br />o2E <br />OX <br />U <br />v:Nl, <br />zWoJ <br />o- <br />I\ <br />Q <br />Z¢OJ <br />a z <br />Q <br />G <br />a <br />O�fin <br />Z <br />°u_o <br />Z <br />W <br />Lli <br />a <br />w 0 <br />� , ° � <br />J <br />r-1 <br />LJ.J <br />z o <br />M <br />Q <br />Z <br />Q�Z <br />Z <br />9 <br />o' <br />06 <br />FZ <br />Qo <br />0 <br />- <br />= <br />­1 <br />Cl- <br />to <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAM ES <br />VERSION N0. 5ol <br />SHEET NO. <br />4.0 <br />