My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3220 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3220 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:11:02 AM
Creation date
2/19/2025 8:59:11 AM
Metadata
Fields
Template:
Building Plans
Street #
3220
Location
Kresterbrooke Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
20296
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />rN <br />M <br />C'4 <br />to <br />n <br />LO <br />cV <br />it <br />(D <br />v <br />S <br />to <br />0 <br />0 <br />J <br />M <br />N <br />W <br />tR <br />00 <br />Cn <br />2 <br />E <br />0 <br />s <br />w <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />NEMA 1 200 AMP #12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER 11 <br />MO ll <br />2/0 or 4/0 SER Alu <br />200 amp <br />150 amp tr <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />RECEPT. <br />FC- - <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />UPPER ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />V <br />Z M <br />O <br />_ <br />z� <br />mot: <br />a <br />�Vn' <br />�WJ w <br />ro Q <br />w <br />O <br />IS/. <br />rN <br />V) ~ <br />o 0 <br />m cN <br />cN <br />C) <br />w <br />r-E <br />N M <br />C ca co <br />O o N <br />dj <br />N <br />U� <br />_ o <br />L LL 00 <br />O f6 ^ <br />o <br />Q� <br />A 1 <br />NN <br />f <br />*I <br />' <br />t <br />� N <br />co <br />N <br />N 0 o Q o M <br />z o <br />Z_ W M <br />th 4) c <br />/y <br />J z <br />LL J <br />I.L <br />N M 16 <br />W N <br />io W 0 m5 <br />W <br />CL,1 <br />z <br />Z ¢ <br />o <br />LLZ N E <br />m CIO <br />W aN¢ <br />o <br />0 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />O <br />Z N <br />O <br />►-A o <br />M <br />> (n 0 <br />M <br />Q <br />a tn•Ld' <br />� <br />LL <br />CL .. <br />Qfa <br />U 0. 00 <br />to <br />Z <br />Lu CD <br />W <br />J C:) <br />d' <br />OZ <br />H <br />z¢a <br />a� <br />f � <br />Z <br />w¢ a. <br />O0 <br />Z �U <br />J <br />ZBWUZ <br />W <br />Q <br />0 0 O n <br />O��g <br />O� <br />O <br />L J <br />2: z <br />IIY <br />w <br />a <br />LU <br />0 <br />G <br />W <br />_ f <br />N <br />CC <br />o <br />¢ <br />U <br />= <br />p <br />J <br />�� <br />o <br />��o <br />I-� <br />O k <br />I <br />U <br />r <br />X <br />N <br />Q <br />g<oa <br />J <br />k <br />uu <br />Q <br />Z <br />�- <br />uu <br />Lat o <br />Z <br />W <br />Ln <br />w <br />= �' <br />J <br />rl <br />Uj <br />8ZU <br />M <br />Q <br />Z <br />&I -a <br />w <br />O� <br />Z <br />Z <br />a& <br />�z <br />m <br />o <br />� <br />_ <br />�¢9 <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAMES <br />VERSION N0. 5ol <br />SHEET NO. <br />4.1 <br />� LlffRff.i..!Ifi114111A1IfR �Itlrlpills ��a��. � ■>I�e�ellml�!11�1r�Ri�r. � �f� <br />