ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />�&GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />O <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />�?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q EXHAUST FAN <br />�O) EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />VLKIFY ML I LK <br />CH CHIMES (OPTIONAL) <br />LOCATION WITH <br />PB PUSH BUTTON SWITCH (OPTIONAL) BUILDER <br />200A <br />INDOOR PANEL <br />CENTER <br />10 #14 copper to tights & cutlets <br />t <br />200 <br />00 AMP <br />MP <br />10 #12 copper to 20 amp ckts <br />10 #10-2 copper to WH <br />10 #10.3 copper to Dryer <br />METER <br />MAIN <br />O2/0 <br />or <br />4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />�9 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />P <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />IMM <br />ELECTRIC METER <br />§W771 <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />L�J <br />�4� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L T J <br />OPT. CEILING FAN <br />A9 <br />(1) PHONE LINE, (1) DATA PORT <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />e <br />a <br />C� <br />0 p <br />z N S <br />z <br />o <br />z <br />M <br />d <br />WJ M <br />N 2 <br />C/7 Y <br />� W a <br />a <br />.O <br />� <br />N <br />�N N <br />fCs <br />_U 00 <br />m <br />o g <br />x� <br />¢ 01 tM <br />sm <br />N N <br />b <br />o `n <br />Z U # <br />g r7 d w Z <br />W <br />� ti� Nz w a <br />0 0 <br />CHO <br />Q° <br />�4� <br />H <br />E Q <br />LL Z U) a <br />a4� <br />W N Q M Ed <br />00 <br />rn <br />0 <br />CV <br />M <br />00 <br />O <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />o <br />coy <br />w <br />M <br />z S <br />z <br />J <br />L.L <br />NE <br />05 <br />zo <br />oLL <br />>m <br />�a <br />_ <br />o <br />E u <br />F— � <br />X� <br />Z® <br />D a <br />w¢ <br />�� <br />❑ <br />— E <br />o <br />N � <br />4 <br />az <br />ao <br />¢ <br />a <br />a <br />ir� <br />L <br />cf) _Y <br />o <br />U <br />'0 <br />01 <br />Z <br />J <br />, <br />W <br />�m <br />U) <br />3 <br />Q � <br />awZ <br />LL° LL <br /><0 <br />U <br />a <br />m w <br />� <br />ow <br />�K <br />_� <br />a <br />w <br />U H <br />o <br />O <br />V- <br />¢ <br />z < <br />a x <br />O ~ <br />c� 3 <br />c O <br />0 <br />> M <br />^L� <br />W <br />'> (3) <br />co <br />,•� <br />co <br />_j <br />O <br />Q <br />U CiCN <br />o <br />V � <br />� <br />z TO <br />r <br />ui <br />T <br />l� co c\ <br />CV iri � <br />o <br />Z <br />z <br />E O cn <br />ro <br />c <br />@ <br />a <br />E .. .a W <br />U _j Q <br />c <br />c <br />JOB <br />NO : 19-5905 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />