My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3224 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3224 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 2:15:14 AM
Creation date
2/19/2025 8:59:30 AM
Metadata
Fields
Template:
Building Plans
Street #
3224
Location
Nubbin Ridge Ln
Contractor
Lennar Homes
Building Plans - Permit #
22238
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RIDGE <br />ATTIC VENTILATION CALCULATIONS - 131 <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Arm <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev ) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />22.00000 <br />2.000000 <br />Floor <br />2002 <br />1922 <br />275 <br />961 <br />69 <br />480 <br />0 <br />606.0 <br />330.0 <br />276.0 <br />(Zone 1) <br />**NOTE** <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN <br />SCALE: %4"=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063, <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />I Attic Ventilation I <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 11300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />**CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />L <br />I� Q <br />0 <br />Q <br />N <br />z o <br />Q v <br />J th <br />M <br />Z v <br />(/� c <br />n' 0 o <br />W u- <br />� V L.0 O <br />.0 <br />JL <br />— <br />12 <br />W F- <br />IVN c E <br />o <br />YZU') = N <br />ru � <br />U m <br />[2LLe <br />o g <br />ml.... <br />I <br />=r <br />U o <br />0m <br />Q - Y <br />W � <br />N �O <br />N <br />U Z LU 2 o N o w Z <br />WZo <br />a <br />o W 6i' <br />d <br />W w W a <br />V <br />WLL <br />Z_ c�aA o <br />Nk\ <br />N <br />� <br />� <br />r <br />�AnSJ <br />0 �,O�� �• <br />Cr <br />.. <br />O F S <br />E S <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and sea]. <br />r_ <br />� <br />M <br />w <br />z <br />co <br />ry <br />Q E <br />E <br />z <br />20 <br />d <br />�� <br />F <br />G <br />} Om <br />z® <br />❑ a <br />OU <br />N <br />o E <br />X U <br />Q <br />�8 <br />O OU <br />(Y <br />OX <br />C:) <br />� <br />pwZ <br />¢o <br />¢� <br />L <br />. (0 <br />_ <br />_ <br />z <br />0 y <br />U <br />y <br />m� <br />O <br />Z <br />J <br />vi <br />� <br />m <br />? <br />o <br />oLL <br />Q W <br />� w <br />ga o <br />UQ <br />ado <br />2 <br />u W <br />oz <br />�~ <br />Wmi <br />r3 <br />za <br />L= <br />rl <br />I3 <br />= O <br />O <br />.y <br />�M <br />wL <br />C <br />cc <br />L.J. <br />0 N� <br />m IY <br />LO <br />.T_ <br />LO <br />z o <br />r <br />iD <br />N '— <br />Cn M <br />o <br />M <br />� CV <br />z <br />z <br />E Q U <br />E <br />Co <br />4 <br />U � Q p <br />_J <br />JOB <br />NO: 19-5905 <br />SCALE : AS NOTED <br />SHEET NO. <br />5.0 <br />