My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3258 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3258 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:11:22 AM
Creation date
2/19/2025 9:00:35 AM
Metadata
Fields
Template:
Building Plans
Street #
3258
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
19518
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />MAIN <br />O <br />200 amp <br />150 amp <br />POWER CO. FEED---_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 <br />NEMA 1 <br />200 AMP <br />#14 copper to lights 8 outlets <br />#12 copperto 20 amp ckts <br />#10-2 copperto WH <br />#10-3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />Fff <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />LrIlh <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />*3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />0 <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />NMI <br />PANEL <br />f <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L J <br />OPT. CEILING FAN <br />GS <br />(1) PHONE LINE, (1) DATA PORT <br />H.B. <br />I Illy_ ENTRY <br />\ WP I <br />CAFE GFI j <br />FAMILY ROOM db <br />\ IRRIGATION <br />PENDANT AS GFI @ 44" A.F.F. <br />PATIO PER SPECS [� <br />CH AHU W.H. 11 -- �I I <br />—— — — — — — — — — — — — — — — — — — — — — — — — — <br />^/ X------------ <br />1a6f9-•I I l <br />ROUGH -IN FbR T-0" T <br />OPT. CLG. FW LIGHT ` i 1 l <br />PRE -WIRE <br />I I <br />GFI <br />OPT. <br />'GARAGE <br />GARAGE I DOOR <br />dFl =qLIGHT AS I GFI <br />fl <br />r Li -- , � - -- - - - - - - - �o VP PER SPEC % <br />laWl „ <br />S.D � y�.p �qpn <br />/ 1 O x� I DW I SDI PW/. GA.F.. F. 2' /:ART�1T�� i <br />/ / 1 GBl .C. WI CH I o a I <br />j <br />/OWNER'I � I I 9-1S I <br />SUITE — --� - L I �� <br />LL v <br />RAG Lu <br />> Lu GFI @ 44 L - - - - - - - - - - - - - <br />GFI GFI A.F.F. <br />G0ROUGH-IN FOR — — — — — — — — — — — — S.D. <br />---------------- <br />I OPT. CLG. FAN/ DEDICATED RECEPTACLE - HALL <br />LIGHT PRE -WIRE 0 FOR MICROWAVE RANGE C.M <br />HOOD PER SPECS <br />FIqP <br />/ / I S.D. S.D. <br />db <br />EDROOM 4 <br />`... I <br />WP--------------- . B H ROUGH-IN1OR�y 12I ` 12GFI OPT. CLG. I/AN/ !!M I IM <br />, ` LIGHT PRE WIRF� W . I.C. <br />. C . ( <br />ROUGH -IN FOR <br />DISC. 4 � � ROUGH -IN FOR <br />FI I G � 1 <br />BEDROOM 2 I LIGHT PRE-WIR� E D F�00 M 3 � OPT. CLG. FAN/ <br />I \LIGHT PRE -WIRE <br />PAJ►i / <br />H.B. <br />VERIFY METER LOCATION <br />WITH BUILDER <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />Ulr_ <br />Z co <br />0 <br />Z <br />� <br />O <br />O <br />Ul) ` <br />W <br />+.J LLJ <br />U — <br />uJ <br />O <br />~ <br />y <br />vi ~ <br />00 <br />m - <br />U <br />L u <br />a,ccn <br />C t0 M <br />F— EE <br />— U <br />N d M <br />O O O <br />Ua) <br />C LL 00 <br />7 <br />U5Qo <br />00 <br />o <br />Qrn <br />rnCL <br />Qo <br />B D® <br />N�C�a�D�C <br />ti <br />o <br />N <br />N <br />cfl <br />CO N <br />O st 6) p <br />UWI <br />O ONO <br />Z o <br />E"0000 <br />�Z . 2 CP C <br />LL <br />J <br />L.L <br />/y N 0 <br />W (n m (M C <br />W <br />d L1J <br />C LL <br />W tiarnnrw <br />rn <br />8w <br />d <br />z <br />� z <br />O <br />H m:?OZ=3 <br />oho <br />O <br />m m <br />LILro <br />ZQ�0°'� <br />Q� <br />J <br />W NaMr <br />o <br />F-i— <br />O L) <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />ON <br />Z <br />0 0 N I. <br />HU.)MO <br />.m <br />a�M� <br />d- <br />Z <br />r7 to •,_ <br />(n 0 <br />Ln <br />Q U_ <br />fa <br />ZQ� U Q 00 <br />Q <br />� <br />Z <br />Lu C:) <br />J C:) <br />W <br />d' <br />�R0 <br />za <br />F <br />z <br />Wa�of <br />r�� <br />J <br />Q <br />zw wWiz <br />W <br />Q <br />a o O n <br />� � � N <br />U <br />o <br />oz <br />zO <br />^L' <br />W <br />>_ <br />G U <br />ZW <br />5 <br />Z <br />OC <br />Ll_1 <br />J <br />=� <br />N <br />W <br />~ <br />o <br />O <br />= <br />O <br />a <br />�W <br />O <br />J <br />ILL <br />o� . <br />oz <br />F <br />0 <br />7 <br />Z <br />�WJ2ma <br />O¢Oa <br />W�za <br />Q <br />o�Y:0 <br />Z <br />^ <br />U5 <br />LU <br />L0 <br />�(5c <br />J <br />--IUj <br />� <br />w o z <br />Pala <br />Q <br />Z <br />w~~ <br />Z <br />l0 <br />Z <br />o <br />� <br />g <br />= <br />aw <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAM ES <br />VERSION NO. 10 <br />SHEET NO. <br />4.0 <br />M <br />
The URL can be used to link to this page
Your browser does not support the video tag.