My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3258 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3258 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:11:22 AM
Creation date
2/19/2025 9:00:35 AM
Metadata
Fields
Template:
Building Plans
Street #
3258
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
19518
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/CAITCI'1 C�r1CCIT <br />VENTED SOFF <br />40 SQ. FT. <br />V CIV 1 CV 0%J Frl 1 <br />61 SQ. FT. <br />ATTIC VENTILATION CALCULATIONS <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />ventilation of vented <br />IN. of <br />of <br />vented <br />ventilation to <br />be provided <br />SQ. IN. of <br />SQ. IN. of(See <br />Ventilators <br />Elev) <br />required soffit <br />ventilation <br />soffit <br />by upper <br />Ventilation <br />Ventilation <br />needed <br />required <br />needed <br />ventilators <br />Main <br />19.000000 <br />2.000000 <br />Floor <br />2276 <br />2185 <br />312 <br />1092 <br />78 <br />546 <br />561.0 <br />285.0 <br />276.0 <br />(Zone 1) <br />**NOTE** <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 5th ED. RESIDENTIAL. <br />VENTED SOFFIT LEGEND <br />IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED <br />AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. <br />IF <br />LABELED AS "VENTED", NO FIRE PROTECTION WILL BE REQUIRED. <br />VENTED SOFFIT <br />=NTED SOFFIT <br />SQ. FT. <br />ROOF PLAN <br />SCALE: Y4'=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />**CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA I LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN, OF NET FREE AREA I UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. <br />** (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of D'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />**Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT <br />**Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed)/86.25 = Amount of O'Hagin Vents Needed <br />(D!P <br />Z M <br />o <br />_ <br />zC.0 <br />z� <br />Q <br />d <br />z <br />V) (D <br />Q) C <br />4-" J w <br />� o <br />Ow <br />~ <br />0 <br />i� t /) ~ <br />o 0 <br />mti <br />U <br />w <br />E p <br />�M M <br />cmco <br />m '6 N <br />O <br />U <br />O p <br />z � <br />U <br />�LL00 <br />OD <br />a°ri <br />C Y <br />Qm <br />n o <br />L0 0 V <br />rnQo <br />A1 <br />NCBDC <br />fig <br />v <br />goo..... <br />ro <br />N <br />. <br />00 <br />co <br />N <br />o p <br />�l d �5� <br />o0 <br />o <br />z <br />z <br />Ct *u- <br />V <br />LU <br />,•fir �• <br />rt o <br />f <br />z <br />� <br />ca <br />4 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z CV <br />0 1� <br />>�Mo <br />M <br />Q V) In <br />U_ <br />fl. ^ <br />U Q� <br />a <br />E <br />z�� <br />W �� <br />d" <br />Oz <br />O <br />w� <br />za <br />F. <br />Y <br />w¢�� <br />Uz00 <br />z�Lu <br />z <br />o <br />a w O n <br />O��S <br />Uu�rzOO <br />y_ <br />ZZ <br />z z <br />ro <br />z <br />D <br />~ <br />27 <br />z <br />O <br />= <br />J <br />QzQ <br />O LL <br />s <br />g� <br />WOO <br />ISe r <br />O <br />O <br />�� <br />N <br />I� <br />Z¢o¢ <br />wiz¢ <br />Q <br />d- <br />otyuJ ty Xa <br />Z <br />� <br />cy <br />Ww <br />Z <br />W <br />Lfi <br />W <br />�ac� <br />J <br />rl <br />L!J <br />�QzO <br />d" <br /><t <br />z <br />t� l- <br />Q �Q z <br />Z <br />Z <br />aZ <br />r^ z <br />�o <br />m <br />Or-, <br />d <br />W <br />= <br />¢z <br />,--I <br />a <br />cn <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAM ES <br />VERSION NO. 10 <br />O <br />SHEET NO. <br />5.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.