My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6670 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6670 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 12:29:41 PM
Creation date
2/19/2025 9:04:42 AM
Metadata
Fields
Template:
Building Plans
Street #
6670
Location
Paden Wheel St
Contractor
Lennar Homes
Building Plans - Permit #
19508
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
G <br />9 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />I <br />I <br />i <br />i <br />i <br />I <br />i <br />I <br />I <br />I <br />i <br />---- - <br />200A INDOOR PANEL <br />CENTER <br />10 #14 copperto lights & outlets <br />NEMA 1 <br />200 AMP <br />10 #12 copper to 20 amp ckts <br />#10.2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />MAIN <br />O210 <br />or <br />4/0 SER Alu <br />200 amp <br />IF <br />150 amp <br />POWER CO. FEED----_ <br />INTERSYSTEM <br />BONDING O <br />TERMINATION PER �1 <br />NEC 08, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j WALL SWITCH <br />$3 THREE-WAY SWITCH <br />$4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />4P.C. LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />02 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />a <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />�p 3" VTR <br />I � I <br />I�� I <br />DB.L I <br />SINN <br />I I I <br />I I r3' <br />I _ 1 <br />L 3" <br />1.5" VTR ill, 3,r <br />I <br />I <br />HANSON <br />4" <br />SWITCH FOR <br />DISPOSAL <br />UNDER <br />CNTR TC <br />PENDANT <br />LIGHTS OVER <br />ISLAND <br />4" <br />2" VTR \Ip <br />KITCHEN <br />Ij <br />SINK W1 STUDOR <br />I <br />WC III 2" VTR I 1 \ <br />3" <br />3"J 3 <br />SHWR 2� I �1 3"� 3rr SINK I I <br />I I , I <br />I WC <br />r 3 <br />TUB <br />" 1 <br />3" <br />SINK I I <br />1 3" <br />WC <br />TUB <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />OPTIONAL LIGHTING <br />SCALE: %4"=1'-0" <br />C/O <br />A/C PAD <br />WP <br />DISC. GFI <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />ALT. <br />II A/C II <br />I PAD <br />I� �I <br />z <br />O <br />Q <br />U <br />O <br />J <br />LU Lu <br />w0 <br />U Co <br />y _ LU_ <br />rl-(CVVIMrZ M0 <br />SPECS /Vr <br />ELECTRICAL PLAN <br />SCALE: Y4"=V-0" <br />U <br />Z o <br />Z <br />Q <br />Z <br />O <br />(D <br />n�n , <br />Q) C <br />W <br />Q <br />'U — <br />LLI <br />O <br />F- <br />O <br />� <br />N <br />o 0 <br />U <br />LU <br />M <br />ct m ce) <br />U <br />T-gm <br />O O <br />oil a) <br />C)rLLGO <br />:5 ao <br />) <br />Cj <br />U �8_ <br />o <br />Q°vt <br />,n v <br />rnQo <br />A1 <br />B D. <br />N C. r;.D C <br />ti <br />"to <br />N <br />GV <br />fw o v rn d <br />0 o p O <br />o cc) <br />Z o <br />Z Wc) rn <br />O <br />z <br />L.L <br />ii rn LL N <br />W a N,N <br />0 <br />LLI <br />a w <br />C LL <br />LU U<2 C- <br />Z <br />-arno <br />O ow <br />OOf <br />m a <br />Z y*� ocpo <br />O <br />m m <br />IL Q N <br />W V Q EJ <br />N Cl) r <br />U <br />O U <br />F- <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />1 <br />O <br />O <br />Z fV <br />ow N <br />CD <br />n> U.) <br />M <br />Q '0 Lf) <br />Q LL <br />Q ^ <br />� � M <br />Ce U� <br />0000 <br />Q <br />Z <br />LUJ <br />� <br />oZ <br />WU_o <br />Z F- <br />wmZZ�,d <br />UO2: 0 <br />OZZOCL <br />Z a U Q <br />2 ZWW al c Z <br />g Z <br />COz°ra W <br />gu <br />Ln 00 <br />040�c0 <br />C)f <br />U=Otwc\l <br />aOZOD <br />M <br />��LLI <br />O <br />Ln <br />f11 <br />f11 <br />Ln <br />LU <br />Lu � O <br />0' Ln 44 0' <br />LL <br />�� Z <br />CC0-2 <br />O <br />Q <br />Q Q <br />vo0 <br />oroWc� <br />-0 <br />fo <br />z <br />� <br />za-07)z <br />wW°Zo0 <br />z <br />v <br />LUw0u-ZQ <br />r1 U <br />�w�o <br />�?Qo° <br />w/ <br />Ln <br />I <br />J Q Q <br />LLB <br />C:)�}. <br />MO <br />v <br />W <br />J 2 Y W <br />_j <br />0 <br />IN <br />u_ <br />W <br />� <br />�- <br />OJ <br />z J <br />g <br />Z <br />W <br />SCALE : AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: MJAMES <br />VERSION NO. <br />106 <br />JOB NO: 17-5173 <br />SHEET NO. <br />3 <br />liIII `1Fii-1, ir�'ii a - __- -__ -. -, TAT t , I I I 1 i � - I �;.: , i 1. . <br />
The URL can be used to link to this page
Your browser does not support the video tag.