Laserfiche WebLink
11 L—. I <br />L .. I _ _.A 1 _ ! _ _.. I <br />1 II _LLL II 'I ' I I I 1 I L_ 1 _ 1 1 1 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />PqF <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />f� SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />24 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />JQ ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />Ci J OPT. CEILING FAN <br />GD (1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />3" VTR AIL <br />�L I <br />I I <br />I I <br />I I <br />I I <br />OPT. <br />I <br />I I LAV LAV <br />r` I HANSON I <br />BOX I <br />3„ <br />I I W/C <br />LAV <br />SHOWER <br />TUB/ <br />W/C SHOWER <br />3" `_217d <br />STUDOR _ <br />T I , DBL SINK <br />VEN <br />�-' W/ DISP. <br />LAV I W/C <br />irk <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />UNIT-C 1624 (1624) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1625 S.F. <br />4875 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10875 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />OTHER L <br />SUBTOTAL: 23060 <br />TOTAL: 33935 <br />1st10KWat10% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9574 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31878 <br />LOAD WATTS --- 240 VOLTS <br />I AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />C.O. <br />DISCONNECT <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT <br />ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT j WP <br />GFI <br />.m <br />I <br />j <br />I <br />DINING �1%, <br />I KITCHEN 1 <br />FI i a <br />GFI <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />194 <br />GREAT ROOM <br />�*%� /�>ROUGH-IN\ <br />y f FOR OPT. <br /><FAN/LIGHT <br />r\o, � <br />I <br />I � <br />1 / <br />DB <br />\Y <br />NTRY <br />IGHT AS GFI <br />ER SPECS <br />DB & GFI TO <br />BE ALIGNED I <br />VERTICALLY <br />IKX <br />I <br />/ <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />NMI <br />150 Or 200 Amp Service Center I 0 <br />� <br />NEMA 1 <br />200 AMP Z <br />0 <br />W <br />QD <br />L <br />ETER MA N \ 0 _ <br />T( <br />1 0.200 A P Serial Cable 0MW <br />..... <br />3R <br />Power Co. Feed #4 Solid COPPER Ground <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />sl �� <br />ll <br />1 • ,1 M111 <br />GFI <br />@ 44" <br />` \ <br />LW_H <br />A.F.F. <br />1 ` 0 <br />I \ <br />/ 1 <br />GARAGE <br />I I <br />\ GARAGE <br />LIGHT AS <br />xPER SPECS <br />GARAGE <br />O <br />DOOR <br />GFI <br />--------------- <br />I <br />I <br />J <br />I <br />I <br />I0 Z <br />I <br />I� Q <br />IQ a <br />I <br />I <br />IU Q <br />I <br />IU <br />0 <br />I <br />I} C <br />ILL- U <br />I <br />I <br />Icr W <br />I <br />ILu <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />1ST ELECTRICAL — UNIT—C 1624 <br />SCALE: Y4"=1'-0" <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />__ - -_ -__ <br />2ND ELECTRICAL — UNIT—C 1624 <br />SCALE: Y4"=1'-0" <br />ss <br />ens <br />s%+ <br />./:.r <br />d <br />y w <br />o <br />L 0 <br />fl O X <br />fn <br />d � N ]C <br />y cL <br />E s o <br />s <br />� d <br />= of c c� <br />a� <br />E <br />R, o <br />1 <br />c14 <br />N <br />a <br />CV <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's <br />signature and seal Is only <br />for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />N CS c: <br />v °°�, �co <br />c <br />ili <br />!'n N r-' <br />tii <br />Q <br />M lei <br />y M v u_ <br />C LL <br />W <br />J LL LL o_ <br />Z <br />a <br />L r03 _ <br />a <br />O <br />7 @ N <br />W��pjO' <br />LL <br />m w <br />Nco 0 <br />co Z Q 0 <br />Z <br />O <br />N O U <br />U <br />W <br />❑❑ <br />(D M <br />co M <br />o <br />(nco <br />r~ <br />V)C1 <br />LL <br />4--J <br />LL <br />� � <br />V <br />0^ <br />ItI,^l1 <br />� v l <br />w <br />) <br />v <br />w <br />J <br />~ F <br />L r65 <br />I <br />el <br />—0 <br />u) <br />_. <br />Q <br />Sm <br />o <br />ry <br />0 <br />0 <br />oLL <br />wo <br />Qs <br />=® <br />E: <br />oo <br />Do <br />Z <br />a E <br />04 <br />go <br />$ <br />oz <br />az <br />w � <br />0 <br />a <br />w� <br />mo <br />rn r <br />h <br />z� <br />Z <br />� Q <br />J <br />m <br />a°0 <br />4 w <br />�z <br />�z <br />Wcuaa <br />ci <br />g� <br />k <br />� <br />aLL <br />clo <br />C <br />0 <br />N <br />r <br />r' <br />a� <br />03 <br />CN <br />0 <br />CID <br />04 <br />LL <br />cv <br />_cv") <br />a <br />LO <br />r <br />00 <br />U <br />N <br />00 <br />°' <br />04 <br />F- <br />O <br />L O <br />00 O <br />T <br />V, <br />OT <br />r <br />GD <br />CAD N <br />ui <br />4 <br />M <br />a <br />Z <br />m <br />Z <br />E O <br />iri CN <br />•— <br />M <br />m <br />a <br />E <br />ci _j <br />a; <br />cc <br />a o <br />0 <br />JOB <br />NO: 22-12493-12498 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />11.2 <br />