Laserfiche WebLink
ti - K <br />I 4 <br />n ■ <br />w <br />a1 <br />a 1 <br />e1 <br />12 <br />� I k*111 -Z 10 11 IT/All I to] 0 = I ki I M <br />FLORIDA APPROVED PRODUCTS LIST <br />Parent royal <br />Manufacturer <br />Cate o <br />Subcate o <br />A/SeAEg/Seg # <br />Product Model # or Name <br />Model Description <br />FL11321.1 <br />Builders Hardware Inc. <br />Exterior Doors <br />Swinging Ext. Door <br />Opaque Fiber lass Door <br />Entry 'Door <br />FL15220.1 <br />Plastico Inc. <br />Exterior Doors <br />SwinginZ Ext. Door Assemblies <br />Opaque Fiber lass Door <br />Glazed Fiber lass Door <br />FLI5279-R1 <br />Cloj221 Building Products C2=any <br />Exterior Doors <br />Sectional Ext. Door Assemblies <br />FL15349-RI <br />MI Windows and Doors <br />Windows <br />Fixed <br />Model 185PW <br />Aluminum <br />FL3664-R3 <br />Tamko Building Products <br />Roofin <br />Underlayments <br />TW Underlayment <br />Self -Adhering Rubberized <br />FL4968.1 <br />Guardian Building Products - Ashlev <br />Panel Walls <br />Soffits <br />16" Ouad Four /4 <br />Aluminum <br />FL9792-R5 <br />Atlas Roofing Co oration <br />Roofing <br />Asphalt Shingles <br />StormMaster Shake <br />Fiberglass Reinforced <br />FL11473-R2 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />LSUU210 <br />1HETA <br />Adjustable hanger <br />FL 11473-R2 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />Embedded Truss Anchor <br />FL11473-R2 <br />Sim son Stron -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />META <br />Embedded Truss Anchor <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />Strap Ties <br />FL11473-R2 <br />Sim son Stron -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />LSTA12 <br />Strap Ties <br />FL11473-R2 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />H2.5 <br />Truss Tie <br />NOTE FLORIDA APPROVED WINDOWS AND DOORS RATED FOR INDICATED DESIGN PRESSURES AND INSTALLED PER DOORMAN UFACTURERS SPECIFICATIONS. <br />GENFEZ.L S'"YRUCTURAL NOTES <br />T14-ESE PLANS Ib'EET THE MINiIvAsUM REQUIREMENTS OF THE 2010 FLORIDA RESIDENTIAL BUILDING CODE, <br />FEC. 2010, & ASCE !-10. <br />1. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI (UNLESS NOTED OTHERWISE) @ 28 DAYS- <br />2. STEEL REINFORCEMENT SHALL HAVE A MINIMUM YIELD STRENGTH OF 40,000 PSI IN ACCORDANCE WITH ASTM A-615. <br />3. CONCRETE MASONRY UNITS, IF ANY, SHALL BE HOLLOW CORE/ LOAD BEARINGS IN ACCORDANCE TO ASTM C90 <br />OR �C145, 1,900,PSI MINIMUM. <br />4. GROUT, IF ANY, SHALL HAVE 3/8" MAXIMUM AGGREGATE, 8-11 INCH SLUMP 2,000 PSI AS PER ASTM C476. <br />5. MORTAP IF ANY, SHALL BE TYPE M OR S IN CONFORMANCE ASTM C270. <br />6. THE OUTER FOUNDATION BARS SHALL BE CONTINOUS AROUND CORNERS BY BENDING THE BAR IN ACCORDANCE <br />WITH 2O23.4 OF THE SSTD 10-99. IN BOTH CASES THE MINIMUM BAR LAP SHALL BE 40 DIAMETER LIKEWISE, THE BOND <br />BEAM REINFORCEMENT SHALL BE CONTIN'OUS AROUND ALL CORNERS. <br />7. ATTACH PLYWOOD SHEATHING TO SUPPORTING TRUSSES OR OTHER FRAMING WITH COMMON NAILS FOR GABLE <br />DIAPHRAGMS ONLY, (UNLESS OTHERWISE NOTED) 8d. <br />A. 4" O.C. ALONG EDGES OF PLYWOOD PANELS. <br />B. 6" OC. ALONG FIELD OF PLYWOOD PANELS. <br />8. PROVIDE 4" X 4" CLEAN OUT FOR ALL CONCRETE FILLED CELLS. AT THE BASE OF WALL. <br />9. ALL WOOD LOAD BEARING EXTERIOR AND INTERIOR WALLS TO BE #2 SOUTHERN YELLOW PINE (OR EQUAL <br />(FB = 1200 PSI) @ 16" O.C. UNLESS NOTED OTHERWISE). <br />10. ALL WOOD GIRDERS SHALL HAVE A MIN. OF (4) - 2"X4" STUDS PLACED DIRECTLY UNDER THE GIRDER AND DOUBLE <br />PLATES. <br />11. PRE -MANUFACTURED ROOF TRUSSES TO BE DESIGNED IN ACCORDANCE WITH THE LATEST TPI DESIGN <br />REQUIREMENTS. THE TRUSS WL",'UFACTURER IS REQUIRED TO FURNISH ALL REACTION LOADS FOR DEAD LOADS, <br />LIVE LOADS AND WIND 1_10�DS, MANUFACTURER TO SUBMIT TRUSS LAYOUT AND DETAILS SIGNED BY A FLORIDA <br />REGISTERED ENGINEER, <br />12. EXTERIOR FRONT AND BACK DOORS, WINDOWS, GARAGE DOORS, CLADDING AND COMPONENTS ARE SUBMITTED <br />WITH THE "TEC IINiCAL MANUAL" FOR INSTALLATION AND TECHNICAL MATERIAL SPECIFICATIONS. <br />13. ALL EXTERIOR CONCRETE BLOCK WALLS ARE DESIGNED AS SHEAR WALS OR SHEAR WALL SEGMENTS WITH <br />DUR-A-WALL F 1,INFORCEME''IT EVERY OTHER. BLOCK AS PER THE REQUIREMENTS OF THE NATIONAL CONCRETE <br />MASONRY INSTITUTE. IF DUR-A-WALL REINFORCEMENT IS NOT USED FOR THE ENTIRE BUILDING, LENGTH OF <br />ACTUAL SHEAR WALL WLL BE DESIGNATED ON THE PLANS. <br />14. ALL OPENINGS GREATER THAN N 5 FEET TO HAVE 145 BAR ON EACH SIDE OF OPENING AND FILLED WITH GROUT. <br />OPENINGS GREATER THAN 12 FEET TO HAVE 245 BARS ON EACH SIDE OF OPENING. <br />15. CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD, <br />16. ANY CHANGES TO SEALED DIU0XINGS MUST BE APPROVED BY THE PROFESSIONAL ENGINEER OF RECORD, <br />17. STRUCTURAL DESIGN CRUTERIA. <br />A. BASIC WIND SPEED = 140 MPH /108 MPH 3 SEC. GUST <br />B. RISK CATEGORY lU <br />C. APPLICABLE INTERNAL PRESSURE COEFFICIENT = WINDWARD <br />LEEWARD �:0.18 <br />18. ASSUMED MINIMUM EXISTING SOIL BEARING PRESSURE = 2500 PSF <br />19. SOIL NOTED AS COMPACTED IS 95% MODIFIED PROCTOR, ASTM D 1557. <br />�t r <br />PLUMBING NOTES <br />1. PROVIDE PLUMBING FIXTURES, AS SELECTED BY PRACTICAL CONST. COMPLETE WITH ALL TRIM TRAPS, STOP VALVES, SUPPLIES <br />AND ESCUTCHEONS, <br />2. ALL PLUMBING SHALL BE IS STRICT ACCORDANCE WITH STANDARD PLUMBING CODES AND LOCAL ORDINANCES. <br />ID 3. SOIL WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC. <br />c� 5 4, ALL WATER PIPING SHALL BY TYPE "L" WITH 95-5 SOLDERED JOINTS OR C.P.V.C. <br />I 5. COPPER PIPING UNDERGROUND AND IN CONTRACT WITH DISSIMILAR METALS SHALL BE COATED WITH TAR ENAMEL AWWA-C-203 <br />jo)L? OREQUAL. <br />I" 6. PROVIDE INDIVIDUAL WATER STOPS AT ALL WATER CLOSETS, LAVATORIES AND KITCHEN SINK INSTALLATIONS. <br />y't 7. RUN ALL PIPES CONCEALED IN WALL, FLOORS, ABOVE CEILINGS OR BELOW GRADE. <br />`S 8. VERIFY ALL ROUGH IN REQUIREMENTS WITH THE FIXTURES THAT ARE SELECTED. <br />9. COORDINATE ALL WORK WITH TRADES. <br />! 10. PROVIDE FULL SIZE PIPING FROM HOT WATER P&T WALVE TO EXTERIOR. <br />f 11. WATER PIPING RUN THROUGH CONCRETE OR MASONRY SHALL BE WRAPPED WITH 10-ML VINYL PLUMBING TAPE. <br />� �}42. HOT WATER PIPING SHALL BE INSULATED IN ACCORDANCE WITH COUNTY WIDE ENERGY CODE. <br />13.40 GALLON WATER HEATER. <br />/�� ✓ 14. TANK TYPE WATER CLOSET VOLUME 1.5 GALLONS. <br />15. WATER -FLOW RATE. SHOWER HEADS 2.5 GPM PRIVATE FACILITES 2.28 GPM <br />16. PLUMBERS MUST USE A METAL OR PLASTIC MATERIAL TO BOX OUT AREAS IN CONCRETE WHERE DRAINS ARE TO BE INSTALLED. <br />v <br />�i ITTHERMAL EXPANSION PROTECTION IS REQUIRED WHEN THE WATER SERVICE IS EQUIPPED WITH A BACKFLOWN PREVENTION DEVICE. <br />'l 18. ALL BACKFLOWN PREVENTION DEVICES ARE REQUIRED TO BE TESTED AND TEST RESULTS SUBMITTED TO THE BUILDING DEPARTMENT <br />BEFORE THE CERTIFICATE OF OCCUPANCY IS ISSUED. <br />19. IN GARAGES ALL WATER HEATERS SHALL BE ELEVATED TO ENSURE THAT THE LOWEST IGNITION SOURCE IS 18" ABLOVE THE FLOOR <br />INCLUDING ELECTRIC WATER HEATERS. <br />FOUNDATION NOTES <br />VERIFY LOCATION OF BUILDING AT SITE USING OWNERS APPROVED PLOT PLAN AND ADJUST CONCRETE FOOTING, SLAB, LANDING, AND <br />STEPS, AS GRADE REQUIRES. IF CONFLICTS BETWEEN EXISTING SITE CONDITIONS AND APPROVED PLOT PLAN ARISE CONTACT BUILDER. <br />1. PREPARE SOIL TO RECEIVE 4" CONCRETE SLAB W/ WIRE MESH OVER 6 MIL VAPOR BARRIER AND CLEAN, WELL COMPACTED, TERMITE <br />TREATED FILL. <br />2. ALL FOOTINGS TO BE 16"W X 8" D W/2 #5 REBAR CONTINUOUS (UNLESS NOTED). <br />3. ALL THICKENED SLABS (BELL FOOTING) TO BE 12" W X 20" D W/ 2 # 5 REBAR CONTINUOUS (PLACE UPLIFT STRAPPING OR ANCHORS <br />AS MAY BE REQUIRED PER CODE). <br />4. ALL COLUMN PAD TO BE 24" X 24" X12" W/ 3- #5 REBAR EACH WAY (UNLESS NOTED). <br />5. ALL THICKENED EDGE SLABS TO BE 12" 12" W/ (1) #5 REBAR, <br />6.THICKENED SLAB AT FLOOR ELEVATION CHANGE IS TO BE 8" D X 16" W/2 45 REBAR CONTINUOUS. <br />7. FILL CORE WITH CONCRETE AND PLACE (1 #5 REBAR VERTICAL FROM FOOTING TO TIE -BEAM. <br />8. PITCH SLAB AT GRADE AT 1" IN 10' TYPICAL (IN DIRECTION OF ARROW). <br />9. RECESS FLOOR SLAB 3/4" AT ALL SLIDING GLASS DOORS AND EXTEND SLAB 1 1/2" PAST BLOCK FACE. <br />10. SEXTEND SLAB EDGE AT EXTERIOR DOORS 1 11/2" PAST BLOCK <br />FACE. �l <br />I�iW.Ij PPW � I "NtTt, �T�iF 'F� � fI'��M I�i�l�'LY FOR REVIEW OF FOUNDATION DESIGN. <br />12. AIR CONDITIONER COMPRESSOR PAD SHALL BE 3'X4'X4" PLACED 8" FROM WALL, TYPICAL OR AS PLANS. <br />13. ALL STONE OR BRICK VINEER FOOTINGS TO BE 22" W X 10" D W/ 345 REBARS CONTINUOUS. <br />14. ALL FOOTING FOR 2 STORY TO BE 20" W X 10" D W/ 345 REBAR CONTINUOUS. <br />15. ALL THICKENED SLAB (BELL FOOTING) W/ 2 STORIES BEARING TO BE 20" W x 20" D W/ 3- #5 REBARS <br />( PLACE UPLIFT STRAPS OR ANCHORS AS MAY BE REQUIRED PER CODE.) <br />16. THICKENED SLAB (BELL FOOTING) WHERE AT BEARING WALL OCCURS AT CHANGE IN FLOOR ELEVATION SHALL BE A MIN. <br />16" D X 16" W CONTINUOUS. <br />18. TERMITE SOIL PROTECTION TO BE PROVIDED BY REGISTERED TERMITICIDES. <br />1. ALL FRAMING MEMBERS SHALL BE WOOD MEMBERS WITH PROPERTIES EQUAL TO OR BETTER THAN THOSE GIVEN BY THE SOUTHERN <br />PINE INSPECTION BUREAU FOR SURFACED DRIED SOUTHERN PINE NO.2 (MINIMUM ALLOWABLE BENDING STRESS - 1290PSI FOR SINGLE <br />MEMBERS USES AND 1400 PSI FOR REPETITIVE MEMBER USES. MODULES OF ELASTICITY-1,600,00 PSP <br />2. ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED. <br />3. ALL ROOF RAFTERS AND PREFABRICATED WOOD TRUSSES SHALL BE SECURELY FASTENED TO THEIR SUPPORTING WALL OR BEAMS <br />WITH HURRICANE CLIPS OR ANCHORS AS NOTED. <br />4. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE LATEST EDITION OF THE"NATIONAL DESIGN <br />SPECIFICATION FOR STRESS -GRADE LUMBER" AND IT'S FASTENERS AS RECOMMENDED BY THE NATIONAL FOREST PRODUCTS ASSOCIATION <br />5. TRUSS MANUFACTURER SHALL SUBMIT SHOP DRAWINGS AND DESIGN NOTE WITH AN ENGINEER SEAL FOR APPROVAL. <br />DESIGN NOTES ARE TO INCLUDE THE RATED LOAD CAPACITY OF THE CONNECTORS USED TO SECURE THE MEMBERS, CERTIFICATION <br />OF THE CONNECTOR CAPACITY'S AND MANUFACTURES LICENSE TO FABRICATE TRUSSES UTILIZING THE CONNECTORS SYSTEM PROPOSED. <br />7. BRIDGING FOR PRE-ENGINEERED TRUSS SHALL BE AS REQUIRED BY TRUSS MANUFACTURER IN ADDITION TO MEMBER SHOW ON <br />DRAWINGS. <br />8. ROOF DECKS SHALL BE 1/2" PLYWOOD OR OSB FOR FIBERGLASS SHINGLE ROOFS AND 5/8" PLYWOOD FOR CONCRETE OR CLAY <br />TILE ROOFS. USE 8D NAILS WITH 6" SPACING AT ALL PANEL EDGES AND 6" SPACING INTERMEDIATE SUPPORTS. PROVIDE <br />PLY CLIPS AT UNSUPPORTED EDGES. <br />9. ALL WOOD FRAME DETAILS SHALL BE IN ACCORDANCE WITH "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION" LATEST <br />ADDITION, NATIONAL FOREST PRODUCTS ASSOCIATION, UNLESS DETAILED OTHERWISE ON THE STRUCTURAL DRAWINGS. <br />10. ROOF LIVE LOAD = 20 PSF. ROOF DEAD LOAD = 20 PSF <br />11. GABLE ENDWALLS ADJACENT TO CATHEDRAL CEILINGS ARE REQUIRED TO BE CONTINUOUS FROM FLOOR TO ROOF DIAPHRAGM. <br />-4 <br />GENERAL NOTES `�" p j <br />1. BUILDER WILL VERIFY ALL DIMENSIONS SHOWN OR IMPLIED BEFORE STARTING ANY WORK. <br />2. BUILDER WILL COMPLY WITH ALL BUILDING CODES BOTH STATE AND LOCAL, AND COMPLY WITH ALL LOCAL AUTHORITES <br />HAVING JURISDICTION. <br />3.IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF THE <br />BUILDING AND COMPONENT PARTS DURING ERECTION THIS INCLUDES BUT IS NOT LIMITED TO THE ADDITION WHATEVER TEMPORARY <br />BRACING, GUYS, OR THE DOWNS THAT MAY BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY <br />OF THE CONTRACTOR AFTER COMPLETION OF THE PROJECT- <br />4. ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE VERIFIED AND SHALL CONFORM TO THE <br />ARCHITECTURAL DRAWINGS, <br />5. NAIL AND GLUE BUCKS, THE WOOD BETWEEN THE DOOR JAMB AND THE WALL. <br />6. THE MULLIONS - STRIPS BETWEEN A SERIES OF WINDOWS - MUST BE CERTIFIED TO WITHSTAND THE DESIGNED WIND CAPACITY. <br />7. WINDOWS AND GLASS DOORS MUST MEET THE IMPACT STANDARDS. WINDOW MFGR MUST HAVE LABELS ATTACHED LISTING <br />MANUFACTURER, PERFORMANCE CHARACTERISTICS AND CERTIFICATION THAT THEY HAVE BEEN TESTED. LABELS MUST STAY ON UNTIL <br />THE FINAL INSPECTION. <br />8. WALL SIDING, INCLUDING BRICK FACING, PAINTED BLOCK OR STUCCO, MUST END 6 INCHES ABOVE THE GROUND TO ALLOW FOR FUTURE <br />TERMITE INSPECTIONS. THE CONTRACTOR CAN PAINT THE BARE BAND OR APPLY A PLASTER -LIKE FINISH LESS THAN 5/8 INCH THICK <br />DIRECTLY TO THE FOUNDATION WALL. <br />9. ANY GLAZING WITHIN 36" HORIZONTALLY AND BELOW 60" OF THE STANDING SURFACE OF BATHTUB, SHOWER,SPA,ETC., SHALL BE <br />SAFETY GLAZED. <br />10. BATHROOM VENTILATION MUST BE MECHNICALLY EXHAUSTED TO BUILDING EXTERIOR. <br />11. EQUIPMENT DISCONNECT MUST BE WITHIN SITE. <br />12. THE EQUIPMENT SERVICE PANEL MUST BE LOCATED WITHIN 6-0" OF ATTIC ACCESS, IF THE AIR HANDLER UNIT IS IN THE ATTIC. <br />13. A FLOAT SWITCH TO SHUT DOWN THE UNIT OR OTHER APPROVED DEVICE TO ALERT THE HOME OWNER THAT THE CONDENSATION <br />DRAIN IS STOPPED UP MUST BE INSTALLED IF THE AIR HANDLER UNIT IS IN THE ATTIC. <br />16. ALL MECHANICAL EQUIPMENT INCLUDING .A/C CONDENSERS, POOL FILTERS AND POOL HEATERS SHALL BE SECURED TO RESIST <br />LOCATION WIND LOADS. <br />MASONRY/CONCRETE NOTES <br />MASONRY NOTES: <br />1. ALL MASONRY IS TO BE 8" HOLLOW UNITS SHALL CONFORM TO ASTM C90, TYPE NI, WITH A MNINIMUM COMPRESSIVE STRENGTH <br />OF 1000 PSI. <br />2. MORTAR SHALL CONFORM TO ASTM C476, TYPE PL, WITH A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI. <br />CONCRETE NOTES; <br />1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. <br />2. ALL REINFORCING STEEL TO BE NEW DOMESTIC DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 GRADE 40 EXCEPT THAT <br />TIES MAY BE DOMESTIC STEEL CONFORMING TO ASTM A-615 GRADE 40. <br />3. WELDED WIRE FABRIC SHALL CONFORM TO A-185. <br />4. CONTRACTOR SHALL VERIFY LOCATIONS OF ALL OPENINGS,SLEEVES,ANCHOR BOLTS,INSERTS,ETC. AS REQUIRED BY OTHER TRADES <br />BEFORE CONCRETE IS PLACED. NO SLEEVES,OPENINGS PR INESERTS MAY BE PLACED IN BEAMS OR SLABS UNLESS APPROVED BY THE <br />ARCHITECT AND SHOWN ON SHOP DRAWINGS. <br />5. ALL REINFORCING DETAILS TO CONFORM TO "MANUEL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES, <br />ACI 315, UNLESS DETAILED OTHERWISE ON STRUCTURAL DRAWINGS. <br />6. PROVIDE SPACERS,CHAIRS,BOLTS,ETC. AS REQUIRED TO ASSEMBLE,PLACE AND SUPPORT ALL REINFORCING IN PLACE. <br />7. PROVIDE CORNER BARS FOR ALL FOOTINGS. <br />8. ALL FOOTING DOWEL BARS SHALL HAVE A STANDARD 90 DEGREE BEND AND SHALL BE EMBEDDED 5 INCHES INTO -INCH FOOTINGS <br />AND A MINIMUM OF 6 INCHES INTO ALL THE OTHERS. DOWEL BARS LAP VERTICAL WALL REINFORCEMENT A MINIMUM OF 25 INCHES. <br />9. GABLE ENDWALLS ADJACENT TO CATHEDRAL CEILINGS ARE REQUIRED TO BE CONTINUOUS FROM FLOOR TO ROOF DIAPHRAGM. <br />REVIEW ®A <br />CITY OF ZEPHI <br />PLAINS EXANI4IN <br />®41 <br />LLS <br />a <br />� <br />• <br />• <br />1 11 <br />W <br />a <br />i s <br />