PLUMBING NOTES
<br />FIXTURE SCHEDULE:
<br />1.
<br />ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT
<br />PROVIDE FIXTURES AS LISTED BELOW OR EQUAL FROM THE FOLLOWING
<br />ACCORDANCE WITH APPLICABLE LOCAL CODES, RULES AND
<br />MANUFACTURES:
<br />ORDINANCES.
<br />AMERICAN STANDARD, KOHLER, ELJER, SLOAN, ZURN, CHICAGO FAUCETS, T&S,
<br />SPERZEL, OLSONITE, JOSAM, ACORN, ELKAY, HALSEY TAILOR,
<br />RHEEM,
<br />2.
<br />ALL MATERIALS SHALL BE NEW.
<br />LOCHINVAR, A.O. SMITH, WADE, SMITH. MODEL NUMBERS SHOWN ARE FOR BASE
<br />UNIT
<br />ONLY, CONTRACTOR IS RESPONSIBLE FOR PRICING
<br />AND ORDERING UNIT
<br />3.
<br />ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING
<br />WITH
<br />ALL OPTIONS AND ACCESSORIES LISTED.
<br />CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE
<br />COMPLETED SYSTEM SHALL BE FULLY OPERATIVE.
<br />S1
<br />ADA SINK SINGLE BOWL
<br />ELKAY LRAD-1722
<br />4.
<br />REQUIRED INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR
<br />8" CENTERS, 8" SPOUT, 4" LEVER HANDLE
<br />CHICAGO 201-317
<br />FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE
<br />FOR THE DURATION OF WORK.
<br />S2
<br />ADA SINK DOUBLE BOWL
<br />ELKAY LRAD-3319
<br />5-1/2" BOWL DEPTH
<br />5.
<br />CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES,
<br />8" CENTERS, 8" SPOUT, 4" LEVER HANDLE
<br />CHICAGO 201-317
<br />INSPECTION AND TESTS.
<br />WHA
<br />WATER HAMMER ARRESTER
<br />SMITH 5000 SERIES
<br />6.
<br />DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT
<br />LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC.
<br />TP
<br />TRAP SEAL PRIMER VALVE
<br />JOSAM 88250
<br />7.
<br />ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO
<br />FD1
<br />FLOOR DRAIN — ROUND, FLAT STRAINER
<br />JOSAM 30000—A
<br />AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION.
<br />FCO
<br />FLOOR CLEANOUT, ADJUSTABLE COLLAR,
<br />JOSAM 58370A-2
<br />8.
<br />CONTRACTOR SHALL GUARANTEE ALL MATERIALS & WORKMANSHIP
<br />BRONZE TOP
<br />FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR
<br />FROM DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE
<br />WCO
<br />WALL CLEANOUT, ROUND STAINLESS STEEL WALL
<br />JOSAM 58600
<br />COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE
<br />ACCESS COVER WITH SCREW
<br />REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION
<br />WHICH MAY HAVE BEEN DAMAGED.
<br />IH
<br />INSTANTANEOUS WATER HEATER
<br />EEMAX SPEX8208TML
<br />8.3 KW, 0 208/1 VAC, MULTI —LAV, 1
<br />9.
<br />PROVIDE SUBMITTALS IN PDF FORMAT FOR REVIEW BY
<br />0.2 GPM TURN ON, SET FOR 115 DEG MAX
<br />ARCH/ENGR PRIOR TO PURCHASING ANY EQUIPMENT OR MATERIALS.
<br />SUBMITTALS SHALL INCLUDE ALL ITEMS AND MATERIALS SUPPLIED BY
<br />SH
<br />ADA SHOWER
<br />CONTRACTOR. SUBMITTALS SHALL HAVE A SUMMARY SHEET SHOWING
<br />PRESSURE BALANCING SHOWER VALVE
<br />CHICAGO SH—PB1-11-23
<br />ALL SCHEDULED INFORMATION. ANY EQUIPMENT OR MATERIALS
<br />WALL SPOUT
<br />INSTALLED WITHOUT REVIEWED SUBMITTALS SHALL BE REMOVED AND
<br />HAND HELD SHOWER, 69" FLEXIBLE STAINLESS
<br />STEEL
<br />REINSTALL AT ARCH/ENGR DISCRETION WITH NO ADDITIONAL
<br />STEEL HOSE, WALL BRACKET, AND 24" SLIDE
<br />COMPENSATION TO CONTRACTOR.
<br />BAR WITH SLIDE BRACKET
<br />MOUNT CONTROLS AND SPRAY HEAD
<br />10.
<br />PROVIDE 2 SETS ( PLUS PDF COPY) OF MAINTENANCE AND
<br />PER F. A. C. B. C. F I G 37(a )
<br />OPERATION MANUALS ON ALL MECHANICAL EQUIPMENT OR SYSTEMS.
<br />FLOOR DRAIN
<br />JOSAM 3000—A,
<br />11,
<br />VERIFY LOCATION, SIZE, DRAINAGE SLOPES, AND INVERTS OF
<br />WB
<br />WATER OUTLET BOX
<br />GUY GRAY
<br />ALL EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION.
<br />1/2" SWEAT QTR TURN WITH HAMMER ARRESTER
<br />MIB12SHA
<br />ADVISE ENGINEER OF ANY DISCREPANCIES.
<br />XIH
<br />EXISTING INSTA—HOT
<br />12.
<br />ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE
<br />CONTROL VALVES AND ACCESS PANELS.
<br />XWC
<br />EXISTING WATER CLOSET
<br />13.
<br />DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL
<br />XUR
<br />EXISTING URINAL
<br />DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS.
<br />XL
<br />EXISTING LAVATORY
<br />14,
<br />ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH
<br />ISOLATOR PAD (HAIR FELT LINING) SUPER STRUT MODEL C/15/16.
<br />XDF
<br />EXISTING DRINKING FOUNTAIN
<br />FILL VOIDS BETWEEN PIPE & WALL/FLOOR SLEEVES WITH FIRE RATED
<br />FOAM.
<br />XEWH
<br />EXISTING ELEC WATER HEATER
<br />15.
<br />PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES. ACCESS
<br />XFD
<br />EXISTING FLOOR DRAIN
<br />PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING. ALL
<br />ACCESS PANELS MUST MATCH THE FINISH OF THE WALL IN WHICH IT
<br />XECO
<br />EXISTING EXTERIOR CLEANOUT
<br />IS INSTALLED.
<br />16.
<br />NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN
<br />ELECTRICAL EQUIPMENT ROOMS.
<br />17.
<br />ALL HOT WATER PIPES, DRAIN PIPING, AND SHARP EDGES,
<br />UNDER SINKS SHALL BE WRAPPED AND INSULATED WITH HANDI—SHIELD
<br />WRAP OR EQUAL.
<br />18.
<br />INSULATE ALL HOT WATER AND RECIRCULATING LINES WITH —
<br />1" THICK FIBERGLASS OR ARMAFLEX.
<br />19.
<br />WATER PIPING SHALL BE TYPE "L" COPPER ABOVE GROUND AND
<br />TYPE "K" BELOW GROUND.
<br />20.
<br />SANITARY DRAIN, WASTE, AND VENT PIPING SHALL BE
<br />SCHEDULE 40 PVC—DWV PIPE AND FITTINGS WITH NSF SEAL OF
<br />APPROVAL, ASTM D2665-82 (PVC) AND ASTM D2661-84 (DWV), AS
<br />MANUFACTURED BY G.S.R., CHARLOTTE PLASTIC PIPE & FOUNDRY
<br />CO., OR EQUAL. MAKE PVC JOINTS WITH PVC—DWV SOLVENT CEMENT,
<br />ASTM D2564-88 "UNI—WELD" 1200 UP TO 6" PIPE DIAMETER.
<br />21.
<br />CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY
<br />FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS PRIOR TO
<br />BID.
<br />@ BLDG #1 FLOOR PLAN - PLUMBING
<br />Izz
<br />d111
<br />2
<br />Z ��
<br />ma
<br />O W
<br />O(
<br />R I,Oz
<br />.6
<br />IN
<br />w_
<br />W
<br />Y
<br />W IL
<br />DATE: 07/31 /20
<br />0.26
<br />W n' PROJECT:. 20027/YO037
<br />z F DRAWN: KG
<br />♦♦ <go CHECKED: DWG
<br />r^/ � W �
<br />V/
<br />Q M
<br />(� W r
<br />V
<br />1000
<br />BUILDING #1
<br />PLUMBING
<br />
|