My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
40119 CR 54
Zephyrhills
>
Building Department
>
Building Plans
>
40119 CR 54
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:00:32 PM
Creation date
2/19/2025 8:50:32 AM
Metadata
Fields
Template:
Building Plans
Street #
40119
Location
CR 54
Contractor
Wayne Crawford Construction
Building Plans - Permit #
731
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC KEYED NOTES: ® ---� <br />1. REMOVE EXISTING GRILLE AND BRANCH DUCT, CAP TRUNK DUCT <br />AS REQUIRED FOR A LEAK FREE SYSTEM. <br />2. EXISTING GRILLE TO REMAIN. IF EXISTING GRILLE OR <br />BRANCH DUCT IS SMALLER THAN SIZE INDICATED, REPLACE WITH <br />SIZE SHOWN. BALANCE FOR CFM INDICATED. CONTRACTOR SHALL <br />VERIFY EXISTING FLEX DUCT AND GRILLES MEET THE FOLLOWING <br />MINIMUM SIZES FOR CFM LISTED. 6"RND 100 CFM MAX, 8"RND 200 <br />CFM MAX, 10" RND 275 CFM MAX, 12" RND 400 CFM MAX. "ETR" I <br />INDICATED EXISTING TO REMAIN THEREFORE NO NEW BALANCE WORK <br />IS REQUIRED. CLEAN AND OR PAINT EXISTING GRILLE AS <br />REQUIRED FOR AS NEW LOOK. <br />3. RELOCATE EXISTING GRILLE. EXTEND OR REPLACE BRANCH <br />DUCT AS REQUIRED. IF EXISTING GRILLE OR BRANCH DUCT IS <br />SMALLER THAN SIZE INDICATED, REPLACE WITH SIZE SHOWN. <br />BALANCE FOR CFM INDICATED. CONTRACTOR SHALL VERIFY <br />EXISTING FLEX DUCT AND GRILLES MEET THE FOLLOWING MINIMUM <br />SIZES FOR CFM LISTED. 6"RND 100 CFM MAX, 8"RND 200 CFM <br />MAX, 10"RND 275 CFM MAX, 12-RND 400 CFM MAX. CLEAN AND OR <br />PAINT EXISTING GRILLE AS REQUIRED FOR AS NEW LOOK. <br />4. PROVIDE NEW GRILLE AND DUCTWORK AS SHOWN. BALANCE FOR <br />CFM INDICATED. <br />_I++ <br />5. EXISTING T-STAT TO REMAIN. VERIFY STAT IS CONNECTED <br />TO EQUIPMENT NOTED, AND IS IN PROPER WORKING ORDER. REPORT <br />ANY DISCREPANCIES TO ARCHITECT AND ENGINEER. <br />6. RELOCATE EXISTING T-STAT. VERIFY STAT IS CONNECTED TO <br />EQUIPMENT NOTED, AND IS IN PROPER WORKING ORDER. REPORT <br />ANY DISCREPANCIES TO ARCHITECT AND ENGINEER. <br />7. EXISTING VAV ZONE DAMPER TO REMAIN. CONTRACTOR SHALL <br />I <br />INSPECT AND SERVICE TO INSURE FIRST CLASS OPERATION. <br />ADJUST MAX CFM TO SUM OF SUPPLY DIFFUSERS CONNECTED TO IT. ` <br />CONTRACTOR SHALL VERIFY WITH MANUFACTURE BOX SIZE CAN MEET <br />CFM'S REQUIRED. REPORT ANY DEFICIENCIES TO ARCHITECT AND <br />ENGINEER. PROVIDE ACCESS DOORS AS NECESSARY FOR SERVICING. <br />ADVISE ARCHITECT/ENGINEER IF BOX NEEDS TO BE RELOCATED FOR <br />SERVICING. UPDATE LANDLORDS EMS GRAPHICS TO DEPIC ANY ZONE <br />AND SETTING CHANGES. EMS SYSTEM SHALL BE UPDATED BY <br />LANDLORDS APPROVED SUBCONTRACTOR. <br />8. EXISTING 15 TON VAV SPLIT SYSTEM TO REMAIN. <br />i <br />CONTRACTOR SHALL INSPECT AND SERVICE TO INSURE FIRST CLASS <br />OPERATION AND THAT ALL CONTROLS, HOTGAS BYPASS, VFD, STATIC <br />®r-------- i r---------� 8 <br />000011, <br />�� vim;1 U 11,01 <br />�,� .�� .�� 1-2 <br />L--__—___J <br />- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - T T - . <br />PRESSURE SENSOR, FREEZE CONTROL ARE WORKING FOR A FULLY �( Ali`-' '■------------------------------- ------ --1------•••-------------'t------------------------------------------------ I <br />s ------- <br />LIT, �_!1 <br />FUNCTIONAL VAV OPERATION. REPORT ANY DEFICIENCIES TO _ <br />ARCHITECT AND ENGINEER. PROVIDE ACCESS DOORS AS NECESSARY <br />. ----- -------------_---•_•-•--- I A�H I <br />FOR SERVICING. ADVISE ARCHITECT/ENGINEER IF AHU NEEDS TO ( '� ~� <br />BE RELOCATED FOR SERVICING. UPDATE LANDLORDS EMS GRAPHICS ' <br />g TO DEP I C ANY ZONE AND SETTING CHANGES. EMS SYSTEM SHALL BE _ - I Ik- '� 1 - <br />- - - - - - - - - <br />V __ <br />UPDATED BY LANDLORDS APPROVED SUBCONTRACTOR. __ "� .0-�i.� <br />9. EXISTING 3 TON GROUND MOUNTED PACKAGE UNIT TO REMAIN. `. <br />CONTRACTOR SHALL INSPECT AND SERVICE TO INSURE FIRST CLASS <br />OPERATION AND THAT ALL CONTROLS ARE WORKING. REPORT ANY -! (I <br />DEFICIENCIES TO ARCHITECT AND ENGINEER. I I <br />I <br />10. EXISTING EXHAUST FAN TO REMAIN. CONTRACTOR SHALL <br />INSPECT AND SERVICE TO INSURE FIRST CLASS OPERATION AND ' <br />THAT ALL CONTROLS ARE WORKING. REPORT ANY DEFICIENCIES TO <br />ARCHITECT AND ENGINEER. I I I I I <br />;ice Ig I IF si <br />r <br />BLDG #1 FLOOR PLAN — HVAC <br />NOKTH SCALE: 1/8 =1 —0 <br />� —1 ■ FYI <br />i ----4 <br />- <br />Al --- � ----- -- �---_ <br />__-- --- <br />f�1175 <br />I 175 L,: <br />175 L+j <br />i <br />7-- <br />Frrs'; 02 <br />WORK + <br />ARL 02 F7K� <br />+ <br />02 i�7K' <br />.7 <br />1751�'�� <br />05 <br />10 <br />�_--- ------- <br />HVAC LEGEND <br />® <br />SMOKE DETECTOR <br />0 <br />THERMOSTAT <br />MOTORIZED DAMPER <br />Ci3 <br />KEYED NOTE: <br />iF <br />EQUIPMENT TAG: (ex. EF-1) <br />SUPPLY AIR DIRECTION <br />-M� <br />RETURN AIR DIRECTION <br />UNDER CUT DOOR <br />uC <br />1" MIN UNLESS INDICATED <br />r <br />INDICATES SUPPLY AIR <br />21 <br />INDICATES RETURN AIR <br />E <br />INDICATES EXHAUST AIR <br />GRILLE MARKER: INDICATES <br />13 12 <br />TYPE "CD" GRILLE WITH 12"X12" <br />NECK, BALANCE FOR 300 CFM. <br />SUPPLY AIR GRILLE IN T-BAR <br />D�l <br />CEILING SEE ARCHITECT'S <br />REFLECTIVE CEILING PLAN <br />SUPPLY AIR GRILLE SURFACE <br />® <br />MOUNTED INTO CEILING TILE <br />OR DRYWALL CEILING. <br />ED <br />WALL CAP <br />FLEXIBLE DUCT: SIZE TO MATCH <br />DIFFUSER NECK SIZE, UNLESS <br />OTHERWISE INDICATED. <br />FLEX DUCT COLLAR W/OBD <br />—T— <br />SPLITTER DAMPER <br />45 DEG TAP WITH DAMPER <br />DUCT TRANSITION <br />OPPOSED BLADE DAMPER (OBD) <br />1 <br />FIRE DAMPER WITH ACCESS DOOR <br />EXISTING DUCTWORK TO REMAIN. <br />■�■■■■ <br />SEAL ALL EXISTING DUCTWORK AS <br />REQUIRED FOR A LEAK FREE SYSTEM. <br />EXISTING FLEXDUCT TO REMAIN <br />F7Y� <br />EXISTING GRILL OR DIFFUSER <br />L' <br />TO REMAIN OR BE RELOCATED <br />EXISTING EQUIPMENT TO REMAIN OR <br />BE RELOCATED IF NOTED. <br />-' <br />■X■■X■ <br />EXISTING DUCTWORK TO BE REMOVED <br />- <br />EXISTING FLEXDUCT TO BE REMOVED <br />EXISTING GRILL OR DIFFUSER <br />- <br />TO BE REMOVED <br />EXISTING VAV BOX TO BE REMOVED. <br />1_I <br />CAP ANY PNEUMATIC LINES SERVING <br />BOX. <br />THE FOLLOWING ABBREVIATIONS INDICATES: <br />E <br />EXISTING <br />R <br />RELOCATE <br />CO <br />CLEANOUT <br />CFM <br />CUBIC FEET PER MINUTE <br />UON <br />UNLESS OTHERWISE NOTED <br />AFF <br />ABOVE FINISHED FLOOR <br />AFG <br />ABOVE FINISHED GRADE <br />NTS <br />NOT TO SCALE <br />NIC <br />NOT IN CONTRACT <br />CONSULTANT: <br />V <br />U <br />D <br />0 <br />0 <br />0 <br />C:) <br />IT <br />_I U-) <br />oM <br />� M <br />Z L <br />0 0 — <br />p: <br />Q L.L.. <br />a- 00 <br />LJJ � ILL <br />Q � C6 <br />Z J <br />J <br />= 0 <br />0 <br />CF) <br />EL ~ r W <br />z ---� v- N <br />REVISIONS <br />dM <br />�o <br />z� <br />Q z$ <br />im <br />V ^S% <br />MF� <br />Z <br />Fr5o <br />W <br />0. -C <br />W M DATE: 07/31 /20 <br />W o46 PROJECT: 20027NO037 <br />Z DRAWN: <br />�g< CHECKED: <br />VJ v aWIc <br />v♦ Z <br />M IL I` <br />t� w <br />V <br />1.00 <br />BUILDING #1 <br />HVAC <br />