My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
40119 CR 54
Zephyrhills
>
Building Department
>
Building Plans
>
40119 CR 54
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:00:32 PM
Creation date
2/19/2025 8:50:32 AM
Metadata
Fields
Template:
Building Plans
Street #
40119
Location
CR 54
Contractor
Wayne Crawford Construction
Building Plans - Permit #
731
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BLDG*2 FLOOR PLAN — HVAC <br />HVAC KEYED NOTES: <br />1. EXISTING GRILLE TO REMAIN. IF EXISTING GRILLE OR <br />4. RELOCATE EXISTING T-STAT. <br />VERIFY STAT IS CONNECTED TO <br />BRANCH DUCT IS SMALLER THAN SIZE INDICATED, REPLACE WITH <br />EQUIPMENT NOTED, AND IS IN <br />PROPER WORKING ORDER. REPORT <br />SIZE SHOWN. BALANCE FOR CFM INDICATED. CONTRACTOR SHALL <br />ANY DISCREPANCIES TO ARCHITECT <br />AND ENGINEER. <br />VERIFY EXISTING FLEX DUCT AND GRILLES MEET THE FOLLOWING <br />MINIMUM SIZES FOR CFM LISTED. 6"RND 100 CFM MAX, 8"RND 200 <br />5. PROVIDE AN 10" RND OUTSIDE <br />AIR DUCT TO WALLCAP. <br />CFM MAX, 10"RND 275 CFM MAX, 12"RND 400 CFM MAX. "ETR" <br />PROVIDE A NORMALLY CLOSED <br />MOTORIZED DAMPER INTERLOCKED <br />INDICATED EXISTING TO REMAIN THEREFORE NO NEW BALANCE WORK <br />WITH IT'S AHU TO OPEN WHEN <br />THE COMPRESSOR OR HEATER IS IN <br />IS REQUIRED. CLEAN AND OR PAINT EXISTING GRILLE AS <br />OPERATION. <br />REQUIRED FOR AS NEW LOOK. <br />6. EXISTING 3.5 TON SPLIT SYSTEM <br />TO REMAIN. CONTRACTOR <br />2. RELOCATE EXISTING GRILLE. EXTEND OR REPLACE BRANCH <br />SHALL INSPECT AND SERVICE <br />TO INSURE FIRST CLASS OPERATION <br />DUCT AS REQUIRED. IF EXISTING GRILLE OR BRANCH DUCT IS <br />AND THAT ALL CONTROLS ARE <br />WORKING FOR A FULLY FUNCTIONAL. <br />SMALLER THAN SIZE INDICATED, REPLACE WITH SIZE SHOWN. <br />REPORT ANY DEFICIENCIES TO <br />ARCHITECT AND ENGINEER. <br />BALANCE FOR CFM INDICATED. CONTRACTOR SHALL VERIFY <br />EXISTING FLEX DUCT AND GRILLES MEET THE FOLLOWING MINIMUM <br />SIZES FOR CFM LISTED. 6" RND 100 CFM MAX, 8" RND 200 CFM <br />MAX, 10" RND 275 CFM MAX, 12" RND 400 CFM MAX. CLEAN AND OR <br />PAINT EXISTING GRILLE AS REQUIRED FOR AS NEW LOOK. <br />3. PROVIDE NEW GRILLE AND DUCTWORK AS SHOWN. BALANCE FOR <br />CFM INDICATED. <br />T BLDG#2 MEZZANINE PLAN - HVAC <br />wx <br />r <br />0 <br />L <br />FARMER <br />ARCHI-FECTURE <br />Daniel H, Farme(A.I.A. <br />License # ARIL0750 <br />Orlando,941 Lake Baldwin Lane <br />PF CONSULTANT: <br />m <br />U) <br />z 0 �® <br />0 <br />< O <br />�-j <br />�LL <br />W � w <br />J <br />o= <br />0 <br />1- 0) _ <br />f <br />Z J N <br />mi mol <br />BUILDING #2 <br />HVAC <br />